These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 16003195)

  • 21. Screw fixation of scaphoid fractures: a biomechanical assessment of screw length and screw augmentation.
    Dodds SD; Panjabi MM; Slade JF
    J Hand Surg Am; 2006 Mar; 31(3):405-13. PubMed ID: 16516734
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study.
    Prayson MJ; Williams JL; Marshall MP; Scilaris TA; Lingenfelter EJ
    J Orthop Trauma; 1997 Nov; 11(8):565-72. PubMed ID: 9415862
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Internal fixation of oblique metacarpal fractures. A biomechanical evaluation by impact loading.
    Firoozbakhsh KK; Moneim MS; Doherty W; Naraghi FF
    Clin Orthop Relat Res; 1996 Apr; (325):296-301. PubMed ID: 8998890
    [TBL] [Abstract][Full Text] [Related]  

  • 24. How to Prevent K-Wire Bounce in Oblique Supracondylar Humerus Fractures.
    Iobst C; Thompson RG; Grauer J; Wheeler P
    J Orthop Trauma; 2018 Dec; 32(12):e492-e496. PubMed ID: 30086035
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical evaluation of a transcondylar screw from the dorsolateral plate support on the stabilization of orthogonal plate configuration in distal humeral fracture.
    Hara A; Kudo T; Ichihara S; Iwase H; Nagao M; Maruyama Y; Kaneko K
    Injury; 2019 Feb; 50(2):256-262. PubMed ID: 30579588
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical testing of an innovative fixation procedure to stabilize olecranon osteotomy.
    Reising K; Konstantinidis L; Helwig P; Wagner FC; Südkamp NP; Strohm PC
    Proc Inst Mech Eng H; 2014 Nov; 228(11):1146-53. PubMed ID: 25500859
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Parallel Plating of Simulated Distal Humerus Fractures Demonstrates Increased Stiffness Relative to Orthogonal Plating With a Distal Humerus Locking Plate System.
    Taylor PA; Owen JR; Benfield CP; Wayne JS; Boardman ND
    J Orthop Trauma; 2016 Apr; 30(4):e118-22. PubMed ID: 26529123
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation.
    Schumer RA; Muckley KL; Markert RJ; Prayson MJ; Heflin J; Konstantakos EK; Goswami T
    J Shoulder Elbow Surg; 2010 Jun; 19(4):495-501. PubMed ID: 20189837
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Distal humerus internal fixation: a biomechanical comparison of 90° and parallel constructs.
    Kollias CM; Darcy SP; Reed JG; Rosvold JM; Shrive NG; Hildebrand KA
    Am J Orthop (Belle Mead NJ); 2010 Sep; 39(9):440-4. PubMed ID: 21290022
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The use of the 3-mm K-Wire to supplement reduction of humeral supracondylar fractures in children.
    Yu SW; Su JY; Kao FC; Ma CH; Yen CY; Tu YK
    J Trauma; 2004 Nov; 57(5):1038-42. PubMed ID: 15580029
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study.
    Tejwani NC; Murthy A; Park J; McLaurin TM; Egol KA; Kummer FJ
    J Trauma; 2009 Mar; 66(3):795-9. PubMed ID: 19276755
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Case-control study on therapeutic effects of different fixation methods with three Kirschners wires for the treatment of humeral supracondylar fractures].
    Liao JX; Wang JW; Zhang AG; Cai JP; Yan SH; Zhu GH
    Zhongguo Gu Shang; 2011 Aug; 24(8):625-8. PubMed ID: 21928663
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Biomechanical comparative study of three types of osteosynthesis in the treatment of supra and intercondylar fractures of the humerus in adults].
    Fornasiéri C; Staub C; Tourné Y; Rumelhart C; Saragaglia D
    Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(3):237-42. PubMed ID: 9255359
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities.
    Schuster I; Korner J; Arzdorf M; Schwieger K; Diederichs G; Linke B
    J Orthop Trauma; 2008 Feb; 22(2):113-20. PubMed ID: 18349779
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Internal fixation of the distal humerus: a biomechanical comparison of methods.
    Helfet DL; Hotchkiss RN
    J Orthop Trauma; 1990; 4(3):260-4. PubMed ID: 2231122
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Evaluation of biomechanical rigidity of K-wire configurations in transverse osteotomies: a comparison of four-point bending test results].
    Pehlivan O; Yilmaz S; Kiral A; Akmaz I; Mahiroğullari M; Kaplan H
    Acta Orthop Traumatol Turc; 2003; 37(5):395-9. PubMed ID: 14963396
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Stability of the distal phalanx fracture - A biomechanical study on the importance of the nail and the influence of fixation by crossing Kirschner wires.
    Wang W; Yu J; Fan CY; Liu S; Zheng X
    Clin Biomech (Bristol, Avon); 2016 Aug; 37():137-140. PubMed ID: 27451079
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical evaluation of the fixation methods for transcondylar fracture of the humerus:ONI plate versus conventional plates and screws.
    Shimamura Y; Nishida K; Imatani J; Noda T; Hashizume H; Ohtsuka A; Ozaki T
    Acta Med Okayama; 2010 Apr; 64(2):115-20. PubMed ID: 20424666
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical comparison of dorsal nail plate versus screw and K-wire construct for extra-articular distal radius fractures in a cadaver bone model.
    Klitscher D; Mehling I; Nowak L; Nowak T; Rommens PM; Müller LP
    J Hand Surg Am; 2010 Apr; 35(4):611-8. PubMed ID: 20353862
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Finite element analysis of modified Slongo's external fixation in the treatment of supracondylar humeral fractures in older children.
    Zhao J; Yao W; Ma J; Lu B; Ma X
    Medicine (Baltimore); 2024 May; 103(18):e37979. PubMed ID: 38701293
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.