BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 16018516)

  • 1. Intrinsic structural failure of polyester (Dacron) vascular grafts. A general review.
    Van Damme H; Deprez M; Creemers E; Limet R
    Acta Chir Belg; 2005; 105(3):249-55. PubMed ID: 16018516
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Dacron and polytetrafluoroethylene aorto-bifemoral grafts].
    Davidović LB; Lotina SI; Kostić DM; Cinara II; Cvetković SD; Stojanović PL; Velimirović LB; Marković DM; Pejkić SL; Pavlović G
    Srp Arh Celok Lek; 1997; 125(3-4):75-83. PubMed ID: 9221522
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Longitudinal rupturing of a knitted Dacron graft 30 years after its implantation.
    Kawajiri H; Watanabe T; Kanda K; Yaku H
    Interact Cardiovasc Thorac Surg; 2014 Jun; 18(6):861-3. PubMed ID: 24608731
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Failure of dacron arterial prostheses caused by structural defects.
    Watanabe T; Kusaba A; Kuma H; Kina M; Okadome K; Inokuchi K
    J Cardiovasc Surg (Torino); 1983; 24(2):95-100. PubMed ID: 6221021
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Late-stage non-anastomotic rupture of axillo-bifemoral bypass graft.
    Shiraishi M; Kimura C; Takeuchi T; Muramatsu K
    Ann Thorac Cardiovasc Surg; 2012; 18(5):485-7. PubMed ID: 22446953
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Late disruption of Dacron aortic grafts.
    Wilson SE; Krug R; Mueller G; Wilson L
    Ann Vasc Surg; 1997 Jul; 11(4):383-6. PubMed ID: 9236995
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electron microscopy study of a vascular prosthesis destructed in vivo reveals fractures in Dacron fibers.
    Woźniak W; Olszewski W; Górski G
    Vascular; 2016 Feb; 24(1):100-2. PubMed ID: 25957345
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Late rupture of knitted Dacron graft.
    Shingu Y; Aoki H; Ebuoka N; Eya K; Takigami K; Oba J
    Ann Thorac Cardiovasc Surg; 2005 Oct; 11(5):343-5. PubMed ID: 16299465
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The composite Corethane/Dacron vascular prosthesis. Canine in vivo evaluation of 4 mm diameter grafts with 1 year follow-up.
    Wilson GJ; MacGregor DC; Klement P; Dereume JP; Weber BA; Binnington AG; Pinchuk L
    ASAIO Trans; 1991; 37(3):M475-6. PubMed ID: 1836338
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A false aneurysm caused by rupture of a double velour Dacron graft. A case report].
    Nakajima J; Ikegami T; Ishihara T; Murakami K; Morimoto K
    Nihon Geka Gakkai Zasshi; 1986 Aug; 87(8):921-5. PubMed ID: 2943979
    [TBL] [Abstract][Full Text] [Related]  

  • 11. True aneurysm in a prosthetic aorto-femoral dacron graft.
    Friedman M; Zelikovski A; Mor C; Reiss R
    J Cardiovasc Surg (Torino); 1989; 30(1):136-7. PubMed ID: 2522452
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anastomotic false aneurysms with aortic Dacron graft after twenty-five years.
    Guidoin R; Downs AR; Barral X; Marois M; Roy PE; King M; Eng P; Gosselin C
    Ann Vasc Surg; 1986 Nov; 1(3):369-73. PubMed ID: 2973798
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [False aneurysm on dacron prosthesis, 20 years after aortofemoral bypass].
    Illuminati G; Bertagni A; Nasti AG; Montesano G
    Ann Chir; 2001 Oct; 126(8):783-5. PubMed ID: 11692765
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Late non-anastomotic false aneurysm formation in femoropopliteal polyethylene terephthalate grafts.
    Arvanitis DP; Georgopoulos SE; Dervisis KI; Argitis VP; Xanthopoulos DK
    Int Angiol; 2001 Dec; 20(4):348-50. PubMed ID: 11782703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical analysis of non-anastomotic aneurysms of implanted prosthetic grafts.
    Yamamoto S; Hoshina K; Kimura H; Okamoto H; Shigematsu K; Miyata T; Watanabe T
    Surg Today; 2014 Oct; 44(10):1855-62. PubMed ID: 24696137
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Factors determining late patency of aortobifemoral bypass graft].
    Davidović LB; Lotina SI; Kostić DM; Cinara II; Cvetković SD; Stojanov PL; Velimirović DB; Marković MM; Pejkić SA; Vukotić AM
    Srp Arh Celok Lek; 1997; 125(1-2):24-35. PubMed ID: 17974352
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spontaneous rupture of a Dacron prosthesis.
    Opsommer JP; Fastrez J
    Acta Chir Belg; 2002 Apr; 102(2):141-4. PubMed ID: 12051090
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dilatation of aorto-bifemoral knitted Dacron grafts after a mean implantation of 5 years.
    Swartbol P; Albrechtsson U; Pärsson H; Norgren L
    Int Angiol; 1996 Sep; 15(3):236-9. PubMed ID: 8971582
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dilation of knitted Dacron aortic prostheses and anastomotic false aneurysms: etiologic considerations.
    Clagett GP; Salander JM; Eddleman WL; Cabellon S; Youkey JR; Olson DW; Hutton JE; Rich NM
    Surgery; 1983 Jan; 93(1 Pt 1):9-16. PubMed ID: 6217568
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Late rupture of knitted Dacron double velour arterial prostheses. Report on four cases.
    Trippestad A
    Acta Chir Scand; 1985; 151(4):391-5. PubMed ID: 2930986
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.