  • 1. Silver alloy catheters.
    Tew L
    Br J Community Nurs; 2005 Jul; 10(7):312; author reply 312. PubMed ID: 16021749
    [No Abstract]   [Full Text] [Related]  

  • 2. Types of urethral catheters for management of short-term voiding problems in hospitalized adults: a short version Cochrane review.
    Schumm K; Lam TB
    Neurourol Urodyn; 2008; 27(8):738-46. PubMed ID: 18951451
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Can silver alloy catheters reduce infection rates?
    Beattie M
    Nurs Times; 2011 Jul 26-Aug 1; 107(29):19-20, 22. PubMed ID: 21941730
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro comparison of nitrofurazone- and silver alloy-coated foley catheters for contact-dependent and diffusible inhibition of urinary tract infection-associated microorganisms.
    Johnson JR; Johnston B; Kuskowski MA
    Antimicrob Agents Chemother; 2012 Sep; 56(9):4969-72. PubMed ID: 22751541
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technological developments in urethral catheters.
    Lazaro-Sioson H; Magallanes DG; Suarez FB
    SCI Nurs; 2001; 18(3):151-3. PubMed ID: 12503460
    [No Abstract]   [Full Text] [Related]  

  • 6. Evidence for the use of silver-alloy-coated urethral catheters.
    Davenport K; Keeley FX
    J Hosp Infect; 2005 Aug; 60(4):298-303. PubMed ID: 15936115
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reducing the risk of catheter-related urinary tract infection.
    Nazarko L
    Br J Nurs; 2008 Sep 11-24; 17(16):1002, 1004, 1006 passim. PubMed ID: 19062452
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comparative evaluation of the efficacy of uncoated and coated with silver silicone urethral catheters for prevention of urinary tract infections among patients of the intensive care unit].
    Sergevnin VI; Klyuchareva NM; Antipin DP; Laricheva EN
    Urologiia; 2016 Apr; (2):33-36. PubMed ID: 28247658
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Relationship between catheter care and catheter-associated urinary tract infection at Japanese general hospitals: a prospective observational study.
    Tsuchida T; Makimoto K; Ohsako S; Fujino M; Kaneda M; Miyazaki T; Fujiwara F; Sugimoto T
    Int J Nurs Stud; 2008 Mar; 45(3):352-61. PubMed ID: 17173921
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intermittent catheterisation with hydrophilic-coated catheters (SpeediCath) reduces the risk of clinical urinary tract infection in spinal cord injured patients: a prospective randomised parallel comparative trial.
    De Ridder DJ; Everaert K; Fernández LG; Valero JV; Durán AB; Abrisqueta ML; Ventura MG; Sotillo AR
    Eur Urol; 2005 Dec; 48(6):991-5. PubMed ID: 16137822
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comment re: Types of urethral catheters for management of short-term voiding problems in hospitalized adults.
    Feneley R
    Neurourol Urodyn; 2008; 27(8):747. PubMed ID: 18951450
    [No Abstract]   [Full Text] [Related]  

  • 12. Comment re: Types of urethral catheters for management of short-term voiding problems in hospitalized adults.
    Stickler D
    Neurourol Urodyn; 2008; 27(8):748. PubMed ID: 18951443
    [No Abstract]   [Full Text] [Related]  

  • 13. Synthesis of AuAg alloy nanoparticles from core/shell-structured Ag/Au.
    Wang C; Peng S; Chan R; Sun S
    Small; 2009 Mar; 5(5):567-70. PubMed ID: 19189329
    [No Abstract]   [Full Text] [Related]  

  • 14. The relationship between the antimicrobial effect of catheter coatings containing silver nanoparticles and the coagulation of contacting blood.
    Stevens KN; Crespo-Biel O; van den Bosch EE; Dias AA; Knetsch ML; Aldenhoff YB; van der Veen FH; Maessen JG; Stobberingh EE; Koole LH
    Biomaterials; 2009 Aug; 30(22):3682-90. PubMed ID: 19394689
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Corrosion behavior of palladium-silver-copper alloys in model saliva.
    Joska L; Poddana M; Leitner J
    Dent Mater; 2008 Aug; 24(8):1009-16. PubMed ID: 18191189
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Direct conversion of silver complexes to nanoscale hexagonal columns on a copper alloy for plasmonic applications.
    Yamamoto YS; Hasegawa K; Hasegawa Y; Takahashi N; Kitahama Y; Fukuoka S; Murase N; Baba Y; Ozaki Y; Itoh T
    Phys Chem Chem Phys; 2013 Sep; 15(35):14611-5. PubMed ID: 23903026
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New developments in ureteral stent design, materials and coatings.
    Chew BH; Duvdevani M; Denstedt JD
    Expert Rev Med Devices; 2006 May; 3(3):395-403. PubMed ID: 16681460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assembly of hybrid oligonucleotide modified gold (Au) and alloy nanoparticles building blocks.
    Kuo YC; Jen CP; Chen YH; Su CH; Tsai SH; Yeh CS
    J Nanosci Nanotechnol; 2006 Jan; 6(1):95-100. PubMed ID: 16573077
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Synthesis of Ag@AgAu metal core/alloy shell bimetallic nanoparticles with tunable shell compositions by a galvanic replacement reaction.
    Zhang Q; Xie J; Lee JY; Zhang J; Boothroyd C
    Small; 2008 Aug; 4(8):1067-71. PubMed ID: 18651712
    [No Abstract]   [Full Text] [Related]  

  • 20. Catheter-associated urinary tract infections: new aspects of novel urinary catheters.
    Ha US; Cho YH
    Int J Antimicrob Agents; 2006 Dec; 28(6):485-90. PubMed ID: 17045784
    [TBL] [Abstract][Full Text] [Related]  