These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 16022450)

  • 1. Ceramic bonding strength of Au-1.6 wt% Ti alloy.
    Ito M; Kikuchi M; Okuno O; Kimura K
    Dent Mater J; 2005 Jun; 24(2):268-74. PubMed ID: 16022450
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading.
    Vásquez VZ; Ozcan M; Kimpara ET
    Dent Mater; 2009 Feb; 25(2):221-31. PubMed ID: 18718654
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ceramic bonding to a machined Au-Ti alloy.
    Kellerhoff RK; Fischer J
    Quintessence Int; 2007; 38(10):867-72. PubMed ID: 18197327
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of thermal and mechanical cycling on the flexural strength of ceramics with titanium or gold alloy frameworks.
    Oyafuso DK; Ozcan M; Bottino MA; Itinoche MK
    Dent Mater; 2008 Mar; 24(3):351-6. PubMed ID: 17688935
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of interfacial variables on ceramic adherence to cast and machined commercially pure titanium.
    Sadeq A; Cai Z; Woody RD; Miller AW
    J Prosthet Dent; 2003 Jul; 90(1):10-7. PubMed ID: 12869969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro fracture strength and thermal shock resistance of metal-ceramic crowns with cast and machined AuTi frameworks.
    Kellerhoff RK; Fischer J
    J Prosthet Dent; 2007 Apr; 97(4):209-15. PubMed ID: 17499090
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of zinc levels in a gold-based alloy on porcelain-metal bonding.
    Asakura M; Kominami Y; Hayashi T; Tsuruta S; Kawai T
    Dent Mater; 2012 May; 28(5):e35-41. PubMed ID: 22418286
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fusion of low-fusing porcelain to Ti-75 alloy: an experimental study.
    He H; Xu L; Wen N; Wang Z; Zheng X
    Chin J Dent Res; 2000 May; 3(1):31-3. PubMed ID: 11314338
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of airborne-particle abrasion and mechanico-thermal cycling on the flexural strength of glass ceramic fused to gold or cobalt-chromium alloy.
    Oliveira de Vasconcellos LG; Silva LH; Reis de Vasconcellos LM; Balducci I; Takahashi FE; Bottino MA
    J Prosthodont; 2011 Oct; 20(7):553-60. PubMed ID: 22003831
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Physical properties of Au-Pt ceramic alloy after recasting].
    Cheng H; Yang S; Li X; Wu W; Zheng M; Wang Y
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2013 Aug; 31(4):412-4. PubMed ID: 23991584
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of small additions of Ir on properties of a binary Au-Ti alloy.
    Fischer J
    Dent Mater; 2002 Jun; 18(4):331-5. PubMed ID: 11992911
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improving the processing of high-gold metal-ceramic frameworks by a pre-firing heat treatment.
    Fischer J; Fleetwood PW
    Dent Mater; 2000 Mar; 16(2):109-13. PubMed ID: 11203531
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The bonding mechanisms of base metals for metal-ceramic crown microstructure analysis of bonding agent and gold bond between porcelain and base metals].
    Wang CC; Hsu CS
    Kaohsiung J Med Sci; 1996 Jun; 12(6):326-38. PubMed ID: 8699570
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Thermal expansion and microstructural analysis of experimental metal-ceramic titanium alloys.
    Zinelis S; Tsetsekou A; Papadopoulos T
    J Prosthet Dent; 2003 Oct; 90(4):332-8. PubMed ID: 14564287
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical properties of cast commercially pure titanium simulating ceramic firing cycles.
    Fonseca JC; Spazzin AO; Naves LZ; Costa AR; Correr-Sobrinho L; Henriques GE
    J Contemp Dent Pract; 2012 Jul; 13(4):476-80. PubMed ID: 23151696
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ceramic bonding to a dental gold-titanium alloy.
    Fischer J
    Biomaterials; 2002 Mar; 23(5):1303-11. PubMed ID: 11804286
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of soldering on the metal-ceramic bond strength of an Ni-Cr base alloy.
    Nikellis I; Levi A; Zinelis S
    J Prosthet Dent; 2005 Nov; 94(5):435-9. PubMed ID: 16275303
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fit of metal ceramic crowns cast in Au-1.6 wt% Ti alloy for different abutment finish line curvature.
    Tao J; Yoda M; Kimura K; Okuno O
    Dent Mater; 2006 May; 22(5):397-404. PubMed ID: 16038971
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the metal-to-ceramic bond strengths of four noble alloys with press-on-metal and conventional porcelain layering techniques.
    Khmaj MR; Khmaj AB; Brantley WA; Johnston WM; Dasgupta T
    J Prosthet Dent; 2014 Nov; 112(5):1194-200. PubMed ID: 25134992
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Properties of test metal ceramic titanium alloys.
    Akagi K; Okamoto Y; Matsuura T; Horibe T
    J Prosthet Dent; 1992 Sep; 68(3):462-7. PubMed ID: 1432762
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.