100 related articles for article (PubMed ID: 16022817)
1. [Prosthetic aortic valve thrombosis after left ventricular assist device implantation].
Cordero A; Castaño S; Rábago G
Rev Esp Cardiol; 2005 Jul; 58(7):863. PubMed ID: 16022817
[No Abstract] [Full Text] [Related]
2. Surgical closure of left ventricular outflow tract after left ventricular assist device implantation in patients with aortic valve pathology.
Cohn WE; Demirozu ZT; Frazier OH
J Heart Lung Transplant; 2011 Jan; 30(1):59-63. PubMed ID: 20884246
[TBL] [Abstract][Full Text] [Related]
3. Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.
Zimpfer D; Zrunek P; Roethy W; Czerny M; Schima H; Huber L; Grimm M; Rajek A; Wolner E; Wieselthaler G
J Thorac Cardiovasc Surg; 2007 Mar; 133(3):689-95. PubMed ID: 17320566
[TBL] [Abstract][Full Text] [Related]
4. Early changes in bioprosthetic heart valves following ventricular assist device implantation.
Butany J; Leong SW; Rao V; Borger MA; David TE; Cunningham KS; Daniel L
Int J Cardiol; 2007 Apr; 117(1):e20-3. PubMed ID: 17254647
[TBL] [Abstract][Full Text] [Related]
5. Aortic valve procedures at the time of ventricular assist device placement.
Goda A; Takayama H; Pak SW; Uriel N; Mancini D; Naka Y; Jorde UP
Ann Thorac Surg; 2011 Mar; 91(3):750-4. PubMed ID: 21352992
[TBL] [Abstract][Full Text] [Related]
6. Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.
Roscitano A; Benedetto U; Sciangula A; Merico E; Barberi F; Bianchini R; Tonelli E; Sinatra R
Eur J Cardiothorac Surg; 2006 Feb; 29(2):139-43. PubMed ID: 16376565
[TBL] [Abstract][Full Text] [Related]
7. Massive aortic thrombus in patient with mechanical prosthetic valve supported with left ventricular assist device.
Tanawuttiwat T; Zelinger AB; Trivedi DA; Tatooles AJ
J Cardiovasc Comput Tomogr; 2011; 5(1):66-7. PubMed ID: 21051308
[TBL] [Abstract][Full Text] [Related]
8. Novel application of Angiojet rheolytic thrombectomy for massive thrombosis of the native aortic valve and Jarvick 2000 ventricular assist device in a patient with end-stage heart failure.
Barbieri A; Bertelli L; Sangiorgi GM
Catheter Cardiovasc Interv; 2011 Nov; 78(6):958-61. PubMed ID: 21805566
[TBL] [Abstract][Full Text] [Related]
9. Off-pump implant of the Jarvik 2000 ventricular assist device through median sternotomy.
Anyanwu AC; Fischer GW; Plotkina I; Pinney S; Adams DH
Ann Thorac Surg; 2007 Oct; 84(4):1405-7. PubMed ID: 17889020
[TBL] [Abstract][Full Text] [Related]
10. Simple mechanical aortic valve closure in ventricular assist device recipients.
Tasset MR; Kavarana MN; Gray LA; Dowling RD
Ann Thorac Surg; 2006 Jul; 82(1):316-8. PubMed ID: 16798240
[TBL] [Abstract][Full Text] [Related]
11. Successful implantation of Berlin Heart INCOR system after Bentall/De Bono operation.
Tschirkov A; Nikolov D; Tinov G; Papantchev V
Interact Cardiovasc Thorac Surg; 2007 Apr; 6(2):225-7. PubMed ID: 17669817
[TBL] [Abstract][Full Text] [Related]
12. Insufficiency of an aortic valve prosthesis due to tissue ingrowth: a case report.
Christiansen S; Fehske W; Autschbach R
Heart Surg Forum; 2007; 10(2):E105-6. PubMed ID: 17597030
[TBL] [Abstract][Full Text] [Related]
13. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.
John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L
Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167
[TBL] [Abstract][Full Text] [Related]
14. Percutaneous ventricular assist device to rescue a patient with profound shock from a thrombosed prosthetic mitral valve.
Solomon H; Lim DS; Ragosta M
J Invasive Cardiol; 2008 Nov; 20(11):E320-3. PubMed ID: 18987410
[TBL] [Abstract][Full Text] [Related]
15. The sandwich plug technique: simple, effective, and rapid closure of a mechanical aortic valve prosthesis at left ventricular assist device implantation.
Cohn WE; Frazier OH
J Thorac Cardiovasc Surg; 2011 Aug; 142(2):455-7. PubMed ID: 21277593
[No Abstract] [Full Text] [Related]
16. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression.
Ruel M; Al-Faleh H; Kulik A; Chan KL; Mesana TG; Burwash IG
J Thorac Cardiovasc Surg; 2006 May; 131(5):1036-44. PubMed ID: 16678587
[TBL] [Abstract][Full Text] [Related]
17. Technical feasibility of Impella Recover 100 microaxial left ventricular assist device placement after biologic aortic valve replacement (21 mm) for postcardiotomy failure.
Strauch JT; Franke UF; Breuer M; Wippermann J; Wittwer T; Madershahian N; Kaluza M; Wahlers T
J Thorac Cardiovasc Surg; 2005 Dec; 130(6):1715-6. PubMed ID: 16308023
[No Abstract] [Full Text] [Related]
18. Use of the percutaneous left ventricular assist device in patients with severe refractory cardiogenic shock as a bridge to long-term left ventricular assist device implantation.
Idelchik GM; Simpson L; Civitello AB; Loyalka P; Gregoric ID; Delgado R; Kar B
J Heart Lung Transplant; 2008 Jan; 27(1):106-11. PubMed ID: 18187095
[TBL] [Abstract][Full Text] [Related]
19. Novel therapeutic aspects of percutaneous aortic valve replacement with the 21F CoreValve Revalving System.
Berry C; Asgar A; Lamarche Y; Marcheix B; Couture P; Basmadjian A; Ducharme A; Laborde JC; Cartier R; Bonan R
Catheter Cardiovasc Interv; 2007 Oct; 70(4):610-6. PubMed ID: 17894307
[TBL] [Abstract][Full Text] [Related]
20. Prognostic value of left ventricular apical tissue removed for HeartMate II left ventricular assist device placement.
Soderlund KA; Chivukula RR; Russell SD; Conte JV; Mudd JO; Halushka MK
Cardiovasc Pathol; 2009; 18(4):217-22. PubMed ID: 18706833
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]