BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

529 related articles for article (PubMed ID: 16030388)

  • 1. A radio-frequency system for in vivo pilot experiments aimed at the studies on biological effects of electromagnetic fields.
    Ardoino L; Lopresto V; Mancini S; Marino C; Pinto R; Lovisolo GA
    Phys Med Biol; 2005 Aug; 50(15):3643-54. PubMed ID: 16030388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Setup and dosimetry for exposure of human skin in vivo to RF-EMF at 900 MHz.
    Toivonen T; Toivo T; Puranen L; Jokela K
    Bioelectromagnetics; 2008 Apr; 29(3):207-12. PubMed ID: 18044739
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 1800 MHz in vitro exposure device for experimental studies on the effects of mobile communication systems.
    Ardoino L; Lopresto V; Mancini S; Pinto R; Lovisolo GA
    Radiat Prot Dosimetry; 2004; 112(3):419-28. PubMed ID: 15494360
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Demodulation in tissue, the relevant parameters and the implications for limiting exposure.
    Silny J
    Health Phys; 2007 Jun; 92(6):604-8. PubMed ID: 17495662
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Electromagnetic fields emitted in radio- and microwave- frequency range: equipment and methods for the environment protection and survey measurements].
    Bieńkowski P
    Med Pr; 2008; 59(6):513-9. PubMed ID: 19388464
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Large scale in vitro experiment system for 2 GHz exposure.
    Iyama T; Ebara H; Tarusawa Y; Uebayashi S; Sekijima M; Nojima T; Miyakoshi J
    Bioelectromagnetics; 2004 Dec; 25(8):599-606. PubMed ID: 15515034
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Metrology of pulse modulated electromagnetic fields with diode-type meters].
    Kubacki R; Kieliszek J; Sobiech J; Puta R
    Med Pr; 2007; 58(1):57-62. PubMed ID: 17571629
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A compact shielded exposure system for the simultaneous long-term UHF irradiation of forty small mammals: I. Electromagnetic and environmental design.
    Moros EG; Straube WL; Pickard WF
    Bioelectromagnetics; 1998; 19(8):459-68. PubMed ID: 9849915
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Compact shielded exposure system for the simultaneous long-term UHF irradiation of forty small mammals. II. Dosimetry.
    Moros EG; Straube WL; Pickard WF
    Bioelectromagnetics; 1999; 20(2):81-93. PubMed ID: 10029134
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro exposure apparatus for ELF magnetic fields.
    Schuderer J; Oesch W; Felber N; Spät D; Kuster N
    Bioelectromagnetics; 2004 Dec; 25(8):582-91. PubMed ID: 15515036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetry of a set-up for the exposure of newborn mice to 2.45-GHZ WiFi frequencies.
    Pinto R; Lopresto V; Galloni P; Marino C; Mancini S; Lodato R; Pioli C; Lovisolo GA
    Radiat Prot Dosimetry; 2010 Aug; 140(4):326-32. PubMed ID: 20418330
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric analysis of the carousel setup for the exposure of rats at 1.62 GHz.
    Schönborn F; Poković K; Kuster N
    Bioelectromagnetics; 2004 Jan; 25(1):16-26. PubMed ID: 14696049
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Exposure setup to study potential adverse effects at GSM 1800 and UMTS frequencies on the auditory systems of rats.
    Lopresto V; Pinto R; De Vita A; Mancini S; Galloni P; Marino C; Ravazzani P; Lovisolo GA
    Radiat Prot Dosimetry; 2007; 123(4):473-82. PubMed ID: 17164273
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Frequency selective solutions for an efficient non-ionising radiation protection in the radiofrequency and microwave ranges.
    Stefanelli R; Trinchero D
    Radiat Prot Dosimetry; 2009 Dec; 137(3-4):231-5. PubMed ID: 19914967
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of complex EMF exposure situations including inhomogeneous field distribution.
    Jokela K
    Health Phys; 2007 Jun; 92(6):531-40. PubMed ID: 17495653
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development and evaluation of intermediate frequency magnetic field exposure system for studies of in vitro biological effects.
    Fujita A; Hirota I; Kawahara Y; Omori H
    Bioelectromagnetics; 2007 Oct; 28(7):538-45. PubMed ID: 17570495
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electromagnetic field measurements using personal exposimeters.
    Knafl U; Lehmann H; Riederer M
    Bioelectromagnetics; 2008 Feb; 29(2):160-2. PubMed ID: 17929265
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Requirements for reliable worst-case assessment of human exposure to RF electromagnetic fields with known uncertainty.
    Christ A
    Health Phys; 2007 Jun; 92(6):554-64. PubMed ID: 17495656
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A doubly resonant cavity for detection of RF demodulation by living cells.
    Balzano Q; Hodzic V; Gammon RW; Davis CC
    Bioelectromagnetics; 2008 Feb; 29(2):81-91. PubMed ID: 17902156
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Empirical and theoretical dosimetry in support of whole body radio frequency (RF) exposure in seated human volunteers at 220 MHz.
    Allen SJ; Adair ER; Mylacraine KS; Hurt W; Ziriax J
    Bioelectromagnetics; 2005 Sep; 26(6):440-7. PubMed ID: 15931686
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.