These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 16038307)

  • 1. High temperature fast chromatography of proteins using a silica-based stationary phase with greatly enhanced low pH stability.
    Yang X; Ma L; Carr PW
    J Chromatogr A; 2005 Jun; 1079(1-2):213-20. PubMed ID: 16038307
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Synthesis and characterization of hypercrosslinked, surface-confined, ultra-stable silica-based stationary phases.
    Trammell BC; Ma L; Luo H; Hillmyer MA; Carr PW
    J Chromatogr A; 2004 Dec; 1060(1-2):61-76. PubMed ID: 15628152
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of acid stable, hyper-crosslinked, silica-based reversed-phase liquid chromatography supports for the separation of organic bases.
    Ma L; Luo H; Dai J; Carr PW
    J Chromatogr A; 2006 May; 1114(1):21-8. PubMed ID: 16516897
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Silica-based, hyper-crosslinked acid stable stationary phases for high performance liquid chromatography.
    Zhang Y; Luo H; Carr PW
    J Chromatogr A; 2012 Mar; 1228():110-24. PubMed ID: 21906745
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An ultra acid stable reversed stationary phase.
    Trammell BC; Ma L; Luo H; Hillmyer MA; Carr PW
    J Am Chem Soc; 2003 Sep; 125(35):10504-5. PubMed ID: 12940717
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Highly cross-linked self-assembled monolayer stationary phases: an approach to greatly enhancing the low pH stability of silica-based stationary phases.
    Trammell BC; Ma L; Luo H; Jin D; Hillmyer MA; Carr PW
    Anal Chem; 2002 Sep; 74(18):4634-9. PubMed ID: 12349964
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Application of silica-based hyper-crosslinked sulfonate-modified reversed stationary phases for separating highly hydrophilic basic compounds.
    Luo H; Ma L; Paek C; Carr PW
    J Chromatogr A; 2008 Aug; 1202(1):8-18. PubMed ID: 18617181
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of trimethylsilane pre-capping on monomeric C18 stationary phases made from high-purity type-B silica substrates: efficiency, retention, and stability.
    Bair MD; Dorsey JG
    J Chromatogr A; 2012 Jan; 1220():35-43. PubMed ID: 22176738
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimization of the synthesis of a hyper-crosslinked stationary phases: a new generation of highly efficient, acid-stable hyper-crosslinked materials for HPLC.
    Zhang Y; Huang Y; Carr PW
    J Sep Sci; 2011 Jun; 34(12):1407-22. PubMed ID: 21567953
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Protein separation using a novel silica-based RPLC/IEC mixed-mode stationary phase modified with N-methylimidazolium ionic liquid.
    Bai Q; Liu Y; Wang Y; Zhao K; Yang F; Liu J; Shen J; Zhao Q
    Talanta; 2018 Aug; 185():89-97. PubMed ID: 29759254
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a novel amide-silica stationary phase for the reversed-phase HPLC separation of different classes of phytohormones.
    Aral H; Aral T; Ziyadanoğulları B; Ziyadanoğulları R
    Talanta; 2013 Nov; 116():155-63. PubMed ID: 24148387
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design of C18 Organic Phases with Multiple Embedded Polar Groups for Ultraversatile Applications with Ultrahigh Selectivity.
    Mallik AK; Qiu H; Oishi T; Kuwahara Y; Takafuji M; Ihara H
    Anal Chem; 2015 Jul; 87(13):6614-21. PubMed ID: 26041430
    [TBL] [Abstract][Full Text] [Related]  

  • 13. pH-dependent selective separation of acidic and basic proteins using quaternary ammoniation functionalized cysteine-zwitterionic stationary phase with RPLC/IEC mixed-mode chromatography.
    Wang J; Wang J; Ning X; Liu J; Xia H; Wan G; Bai Q
    Talanta; 2021 Apr; 225():122084. PubMed ID: 33592796
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Loss of bonded phase in reversed-phase liquid chromatography in acidic eluents and practical ways to improve column stability.
    Ma L; Carr PW
    Anal Chem; 2007 Jun; 79(12):4681-6. PubMed ID: 17506522
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A pH-stable, crosslinked stationary phase based on the thiol-yne reaction.
    Shields EP; Weber SG
    J Chromatogr A; 2019 Aug; 1598():132-140. PubMed ID: 30981512
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins.
    Skudas R; Grimes BA; Machtejevas E; Kudirkaite V; Kornysova O; Hennessy TP; Lubda D; Unger KK
    J Chromatogr A; 2007 Mar; 1144(1):72-84. PubMed ID: 17084406
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of several stationary phases prepared by thermal immobilization of poly(methyltetradecylsiloxane) onto silica surfaces.
    Borges EM; Collins CH
    J Chromatogr A; 2011 Jul; 1218(28):4378-88. PubMed ID: 21636090
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography.
    Claessens HA; van Straten MA
    J Chromatogr A; 2004 Dec; 1060(1-2):23-41. PubMed ID: 15628150
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Synthesis and optimization of SiO
    Yang X; Wan G; Ma S; Xia H; Wang J; Liu J; Liu Y; Chen G; Bai Q
    Talanta; 2020 Jan; 207():120310. PubMed ID: 31594599
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 13.