These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 1606703)

  • 1. A sequential and simple determination of zinc, copper and aluminium in blood samples by inductively coupled plasma atomic emission spectrometry.
    Chappuis P; Poupon J; Rousselet F
    Clin Chim Acta; 1992 Mar; 206(3):155-65. PubMed ID: 1606703
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Method for measurement of serum copper, zinc and selenium using total reflection X-ray fluorescence spectroscopy on the PICOFOX analyser: Validation and comparison with atomic absorption spectroscopy and inductively coupled plasma mass spectrometry.
    Jeffery J; Frank AR; Hockridge S; Stosnach H; Costelloe SJ
    Ann Clin Biochem; 2019 Jan; 56(1):170-178. PubMed ID: 30056759
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multi-elements (aluminium, copper, magnesium, manganese, selenium and zinc) determination in serum by dynamic reaction cell-inductively coupled plasma-mass spectrometry.
    Wah Fong BM; Siu TS; Kit Lee JS; Tam S
    Clin Chem Lab Med; 2009; 47(1):75-8. PubMed ID: 19055466
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of an inductively coupled plasma-atomic emission spectrometry method for the determination of calcium, magnesium, sodium, potassium, copper and zinc with atomic absorption spectroscopy and flame photometry methods.
    Dipietro ES; Bashor MM; Stroud PE; Smarr BJ; Burgess BJ; Turner WE; Neese JW
    Sci Total Environ; 1988 Aug; 74():249-62. PubMed ID: 3222695
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of aluminium in serum, dialysate fluid and water by inductively coupled plasma optical emission spectrometry.
    Lyon TD; Cunningham C; Halls DJ; Gibbons J; Keating A; Fell GS
    Ann Clin Biochem; 1995 Mar; 32 ( Pt 2)():160-6. PubMed ID: 7785943
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aluminum, zinc and copper concentrations in plasma in chronic renal insufficiency.
    Zumkley H; Bertram HP; Lison A; Knoll O; Losse H
    Clin Nephrol; 1979 Jul; 12(1):18-21. PubMed ID: 477052
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of aluminium in serum and urine for the biomonitoring of occupational exposure.
    Valkonen S; Aitio A
    Sci Total Environ; 1997 Jun; 199(1-2):103-10. PubMed ID: 9200852
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rapid and direct determination of selenium, copper, and zinc in blood plasma by flow injection-inductively coupled plasma-mass spectrometry.
    Kobayashi K; Katsuya Y; Abdulah R; Koyama H
    Biol Trace Elem Res; 2007 Jan; 115(1):87-93. PubMed ID: 17406076
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study of trace elements in patients on haemodialysis.
    Löcsey L; Papp L
    Int Urol Nephrol; 1983; 15(3):289-95. PubMed ID: 6654635
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of the Randox colorimetric assays for serum copper and zinc.
    Handley SA; Wanandy T; Prentice L
    Ann Clin Biochem; 2024 May; 61(3):182-194. PubMed ID: 37789002
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Adsorption-desorption processes of aluminium, zinc and copper on plastic tubing in haemodialysis monitors.
    Milacic R; Benedik M; Knezević S
    Clin Chim Acta; 1997 Sep; 265(2):169-82. PubMed ID: 9385459
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Copper and zinc in human serum in Norway. Relationship to geography, sex and age.
    Helgeland K; Haider T; Jonsen J
    Scand J Clin Lab Invest; 1982 Feb; 42(1):35-9. PubMed ID: 7134789
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Spectrometry emission by inductively coupled plasma (SEPIHF). Application in the determination of inorganic compounds].
    Houot O; Chappuis P; Bourdon R; Arnaud J
    Ann Biol Clin (Paris); 1989; 47(8):475-84. PubMed ID: 2604061
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Copper and zinc determination in plasma and corpuscular components of peripheral blood of patients with preterminal and terminal renal failure.
    Schmitt Y
    J Trace Elem Med Biol; 1997 Dec; 11(4):210-4. PubMed ID: 9575471
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Determination of aluminium in blood-serum by inductively coupled plasma (ICP)-spectroscopy (author's transl)].
    Schramel P; Wolf A; Klose BJ
    J Clin Chem Clin Biochem; 1980 Sep; 18(9):591-3. PubMed ID: 7441187
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A micromethod for determination of serum zinc and copper concentration in infants aged 1-3 months in Chengdu].
    Yang W; Qian Y; Zheng D
    Hua Xi Yi Ke Da Xue Xue Bao; 1991 Jun; 22(2):201-3. PubMed ID: 1786961
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of copper, zinc and aluminium from dietary sources in the femur, brain and kidney of guinea pigs and a study of some elements in in vivo intestinal digesta by size-exclusion chromatography inductively coupled plasma mass spectrometry.
    Owen LM; Crews HM; Massey RC; Bishop NJ
    Analyst; 1995 Mar; 120(3):705-12. PubMed ID: 7741222
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of zinc, copper, and selenium on placental cadmium transport.
    Zhang Y; Zhao Y; Wang J; Zhu H; Liu Q; Fan Y; Wang N; Liu A; Liu H; Ou-Yang L; Zhao J; Fan T
    Biol Trace Elem Res; 2004; 102(1-3):39-49. PubMed ID: 15621926
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of aluminum in bone in haemodialyzed patients, using inductively coupled argon plasma emission spectrometry.
    Leflon P; Plaquet R; Morinière P; Fournier A
    Clin Chim Acta; 1990 Oct; 191(1-2):31-8. PubMed ID: 2073732
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Serum aluminium measurement by DC plasma emission spectrometry.
    Roberts NB; Williams P
    Ann Clin Biochem; 1988 Mar; 25 ( Pt 2)():169-75. PubMed ID: 3382147
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.