  • 1. Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys.
    Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM
    J Biomed Mater Res A; 2005 Nov; 75(2):256-67. PubMed ID: 16078209
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys.
    Poon RW; Yeung KW; Liu XY; Chu PK; Chung CY; Lu WW; Cheung KM; Chan D
    Biomaterials; 2005 May; 26(15):2265-72. PubMed ID: 15585228
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of nickel suppression and cytocompatibility of surface-treated nickel-titanium shape memory alloys by using plasma immersion ion implantation.
    Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM
    J Biomed Mater Res A; 2005 Mar; 72(3):238-45. PubMed ID: 15662652
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Surface characteristics, mechanical properties, and cytocompatibility of oxygen plasma-implanted porous nickel titanium shape memory alloy.
    Wu SL; Chu PK; Liu XM; Chung CY; Ho JP; Chu CL; Tjong SC; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2006 Oct; 79(1):139-46. PubMed ID: 16779766
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages.
    Liu XM; Wu SL; Chan YL; Chu PK; Chung CY; Chu CL; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2007 Aug; 82(2):469-78. PubMed ID: 17295249
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
    Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
    Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of oxygen plasma immersion ion implantation treatment on corrosion resistance and cell adhesion of titanium surface.
    Yang CH; Wang YT; Tsai WF; Ai CF; Lin MC; Huang HH
    Clin Oral Implants Res; 2011 Dec; 22(12):1426-32. PubMed ID: 21457349
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study on hemocompatibility and corrosion behavior of ion implanted TiNi shape memory alloy and Co-based alloys.
    Liang C; Huang N
    J Biomed Mater Res A; 2007 Oct; 83(1):235-40. PubMed ID: 17607737
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy.
    Chu CL; Guo C; Sheng XB; Dong YS; Lin PH; Yeung KW; Chu PK
    Acta Biomater; 2009 Jul; 5(6):2238-45. PubMed ID: 19251496
    [TBL] [Abstract][Full Text] [Related]  

  • 11. NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization.
    Yahia LH; Lombardi S; Piron D; Klemberg-Sapieha JE; Wertheimer MR
    Med Prog Technol; 1996-1997; 21(4):187-93. PubMed ID: 9110276
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of calcium and phosphorus ion implantation on the corrosion resistance and biocompatibility of titanium.
    Krupa D; Baszkiewicz J; Kozubowski JA; Lewandowska-Szumieł M; Barcz A; Sobczak JW; Biliński A; Rajchel A
    Biomed Mater Eng; 2004; 14(4):525-36. PubMed ID: 15472399
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Corrosion behaviour, metal release and biocompatibility of implant materials coated by TiO2-sol gel chemistry].
    Hoffmann B; Kokott A; Shafranska O; Detsch R; Winter S; Eisenbarth E; Peters K; Breme J; Kirkpatrick CJ; Ziegler G
    Biomed Tech (Berl); 2005 Oct; 50(10):320-9. PubMed ID: 16300047
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparative study of the cytotoxicity and corrosion resistance of nickel-titanium and titanium-niobium shape memory alloys.
    McMahon RE; Ma J; Verkhoturov SV; Munoz-Pinto D; Karaman I; Rubitschek F; Maier HJ; Hahn MS
    Acta Biomater; 2012 Jul; 8(7):2863-70. PubMed ID: 22465573
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution.
    Cissé O; Savadogo O; Wu M; Yahia L
    J Biomed Mater Res; 2002 Sep; 61(3):339-45. PubMed ID: 12115458
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nickel release behavior, cytocompatibility, and superelasticity of oxidized porous single-phase NiTi.
    Wu S; Liu X; Chan YL; Ho JP; Chung CY; Chu PK; Chu CL; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2007 Jun; 81(4):948-55. PubMed ID: 17252548
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys.
    Shabalovskaya SA
    Biomed Mater Eng; 1996; 6(4):267-89. PubMed ID: 8980835
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires.
    Walker MP; White RJ; Kula KS
    Am J Orthod Dentofacial Orthop; 2005 Jun; 127(6):662-9. PubMed ID: 15953890
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improvement of surface bioactivity on titanium by water and hydrogen plasma immersion ion implantation.
    Xie Y; Liu X; Huang A; Ding C; Chu PK
    Biomaterials; 2005 Nov; 26(31):6129-35. PubMed ID: 15885768
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Electrochemical properties of biocompatible material hardness modifications on titanium and steel under mechanical loads].
    Braun W; Walter U; Holbein R; Thull R
    Biomed Tech (Berl); 2005 Apr; 50(4):100-6. PubMed ID: 15884706
    [TBL] [Abstract][Full Text] [Related]  