BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

469 related articles for article (PubMed ID: 16085624)

  • 1. Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years.
    Dorr LD; Wan Z; Shahrdar C; Sirianni L; Boutary M; Yun A
    J Bone Joint Surg Am; 2005 Aug; 87(8):1816-21. PubMed ID: 16085624
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.
    McCalden RW; MacDonald SJ; Rorabeck CH; Bourne RB; Chess DG; Charron KD
    J Bone Joint Surg Am; 2009 Apr; 91(4):773-82. PubMed ID: 19339560
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical and radiological results with a 36-mm cobalt-chrome prosthetic head, cross-linked Durasul liners associated with Allofit cups: a more than 10-year follow-up period.
    Georis P; Thirion T; Gillet P
    Hip Int; 2020 Jul; 30(4):446-451. PubMed ID: 31431079
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.
    Ayers DC; Greene M; Snyder B; Aubin M; Drew J; Bragdon C
    J Bone Joint Surg Am; 2015 Apr; 97(8):627-34. PubMed ID: 25878306
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparative study on high cross-linked and traditional polyethylene cup liners in total hip arthroplasty].
    Wei Z; Sun J; Zha G; Dong S; Wang T; Fany Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1414-8. PubMed ID: 24640355
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New polyethylenes in total hip arthroplasty : a 20- to 22-year follow-up study.
    García-Rey E; Cruz-Pardos A; Saldaña L
    Bone Joint J; 2022 Sep; 104-B(9):1032-1038. PubMed ID: 36047028
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.
    Thomas GE; Simpson DJ; Mehmood S; Taylor A; McLardy-Smith P; Gill HS; Murray DW; Glyn-Jones S
    J Bone Joint Surg Am; 2011 Apr; 93(8):716-22. PubMed ID: 21508278
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative long-term survivorship of uncemented acetabular components in revision total hip arthroplasty.
    Kremers HM; Howard JL; Loechler Y; Schleck CD; Harmsen WS; Berry DJ; Cabanela ME; Hanssen AD; Pagnano MW; Trousdale RT; Lewallen DG
    J Bone Joint Surg Am; 2012 Jun; 94(12):e82. PubMed ID: 22717834
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up.
    Hanna SA; Somerville L; McCalden RW; Naudie DD; MacDonald SJ
    Bone Joint J; 2016 Jan; 98-B(1):28-32. PubMed ID: 26733512
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis.
    Meftah M; Klingenstein GG; Yun RJ; Ranawat AS; Ranawat CS
    J Bone Joint Surg Am; 2013 Jul; 95(13):1193-7. PubMed ID: 23824387
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis.
    Digas G; Kärrholm J; Thanner J; Malchau H; Herberts P
    Clin Orthop Relat Res; 2004 Dec; (429):6-16. PubMed ID: 15577460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Comparative study on association between femoral head size and linear wear rate of highly cross-linked polyethylene liner].
    Guo S; Sun J; Zha G; Wei S; Lu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Nov; 28(11):1333-7. PubMed ID: 25639045
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results.
    Dorr LD; Wan Z; Longjohn DB; Dubois B; Murken R
    J Bone Joint Surg Am; 2000 Jun; 82(6):789-98. PubMed ID: 10859098
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early outcomes of sequentially cross-linked thin polyethylene liners with large diameter femoral heads in total hip arthroplasty.
    Sayeed SA; Mont MA; Costa CR; Johnson AJ; Naziri Q; Bonutti PM; Delanois RE
    Bull NYU Hosp Jt Dis; 2011; 69 Suppl 1():S90-4. PubMed ID: 22035492
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fifteen-Year Results of Total Hip Arthroplasty With Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.
    Rames RD; Stambough JB; Pashos GE; Maloney WJ; Martell JM; Clohisy JC
    J Arthroplasty; 2019 Jun; 34(6):1143-1149. PubMed ID: 30808529
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Highly Cross-Linked Polyethylene in Total Hip Arthroplasty in Patients Younger Than 50 Years With Osteonecrosis of the Femoral Head: A Minimum of 10 Years of Follow-Up.
    Min BW; Cho CH; Son ES; Lee KJ; Lee SW; Song KS
    J Arthroplasty; 2020 Mar; 35(3):805-810. PubMed ID: 31690522
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty.
    Tian JL; Sun L; Hu RY; Han W; Tian XB
    Orthop Surg; 2017 May; 9(2):186-190. PubMed ID: 28557297
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Early failure of the polyethylene liner in the ABG I total hip prosthesis].
    Gallo J; Kamínek P; Zapletalová J; Novotný R; Cechová I; Ditmar R
    Acta Chir Orthop Traumatol Cech; 2003; 70(6):343-9. PubMed ID: 15002349
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New polyethylenes in total hip replacement: A ten- to 12-year follow-up study.
    García-Rey E; García-Cimbrelo E; Cruz-Pardos A
    Bone Joint J; 2013 Mar; 95-B(3):326-32. PubMed ID: 23450015
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.