These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 16086020)

  • 41. Biocompatibility of corrosion-resistant zeolite coatings for titanium alloy biomedical implants.
    Bedi RS; Beving DE; Zanello LP; Yan Y
    Acta Biomater; 2009 Oct; 5(8):3265-71. PubMed ID: 19433139
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Ultrasonic irradiation and its application for improving the corrosion resistance of phosphate coatings on aluminum alloys.
    Sheng M; Wang C; Zhong Q; Wei Y; Wang Y
    Ultrason Sonochem; 2010 Jan; 17(1):21-5. PubMed ID: 19692286
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Electrochemical characteristic of TiNi shape memory alloy in artificial body fluids.
    Liang C; Huang N
    J Biomed Mater Res A; 2009 Apr; 89(1):266-9. PubMed ID: 18491391
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Control of metallic corrosion through microbiological route.
    Maruthamuthu S; Ponmariappan S; Mohanan S; Palaniswamy N; Palaniappan R; Rengaswamy NS
    Indian J Exp Biol; 2003 Sep; 41(9):1023-9. PubMed ID: 15242295
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Corrosion protection of AZ31 alloy and constrained bacterial adhesion mediated by a polymeric coating obtained from a phytocompound.
    Bertuola M; Miñán A; Grillo CA; Cortizo MC; Fernández Lorenzo de Mele MA
    Colloids Surf B Biointerfaces; 2018 Dec; 172():187-196. PubMed ID: 30153620
    [TBL] [Abstract][Full Text] [Related]  

  • 46. In vitro corrosion and biocompatibility of binary magnesium alloys.
    Gu X; Zheng Y; Cheng Y; Zhong S; Xi T
    Biomaterials; 2009 Feb; 30(4):484-98. PubMed ID: 19000636
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Silica nanocontainers for active corrosion protection.
    Maia F; Tedim J; Lisenkov AD; Salak AN; Zheludkevich ML; Ferreira MG
    Nanoscale; 2012 Feb; 4(4):1287-98. PubMed ID: 22249939
    [TBL] [Abstract][Full Text] [Related]  

  • 48. In vitro and in vivo corrosion measurements of magnesium alloys.
    Witte F; Fischer J; Nellesen J; Crostack HA; Kaese V; Pisch A; Beckmann F; Windhagen H
    Biomaterials; 2006 Mar; 27(7):1013-8. PubMed ID: 16122786
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Synergistic cytotoxic effects of ions released by zinc-aluminum bronze and the metallic salts on osteoblastic cells.
    Grillo CA; Morales ML; Mirífico MV; Fernández Lorenzo de Mele MA
    J Biomed Mater Res A; 2013 Jul; 101(7):2129-40. PubMed ID: 23596152
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Bioactivation of a cobalt alloy by coating with wollastonite during investment casting.
    Almanza JM; Escobedo JC; Ortiz JC; Cortés DA
    J Biomed Mater Res A; 2006 Jul; 78(1):34-41. PubMed ID: 16598727
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Comparative corrosion study of "Ni-free" austenitic stainless steels in view of medical applications.
    Reclaru L; Ziegenhagen R; Eschler PY; Blatter A; Lemaître J
    Acta Biomater; 2006 Jul; 2(4):433-44. PubMed ID: 16765883
    [TBL] [Abstract][Full Text] [Related]  

  • 52. In vivo corrosion and corrosion protection of magnesium alloy LAE442.
    Witte F; Fischer J; Nellesen J; Vogt C; Vogt J; Donath T; Beckmann F
    Acta Biomater; 2010 May; 6(5):1792-9. PubMed ID: 19822226
    [TBL] [Abstract][Full Text] [Related]  

  • 53. In vitro biocorrosion of Co-Cr-Mo implant alloy by macrophage cells.
    Lin HY; Bumgardner JD
    J Orthop Res; 2004 Nov; 22(6):1231-6. PubMed ID: 15475202
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The effect of Nb addition on mechanical properties, corrosion behavior, and metal-ion release of ZrAlCuNi bulk metallic glasses in artificial body fluid.
    Qiu CL; Liu L; Sun M; Zhang SM
    J Biomed Mater Res A; 2005 Dec; 75(4):950-6. PubMed ID: 16206266
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Halloysite tubes as nanocontainers for anticorrosion coating with benzotriazole.
    Abdullayev E; Price R; Shchukin D; Lvov Y
    ACS Appl Mater Interfaces; 2009 Jul; 1(7):1437-43. PubMed ID: 20355946
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Cobalt-containing alloys and their ability to release cobalt and cause dermatitis.
    Julander A; Hindsén M; Skare L; Lidén C
    Contact Dermatitis; 2009 Mar; 60(3):165-70. PubMed ID: 19260915
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effects of pH and fluoride concentration on the corrosion of titanium.
    Lindholm-Sethson B; Ardlin BI
    J Biomed Mater Res A; 2008 Jul; 86(1):149-59. PubMed ID: 17957718
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva.
    Bilhan H; Bilgin T; Cakir AF; Yuksel B; Von Fraunhofer JA
    J Biomater Appl; 2007 Nov; 22(3):197-221. PubMed ID: 17255155
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Degradation of magnesium and its alloys: dependence on the composition of the synthetic biological media.
    Mueller WD; de Mele MF; Nascimento ML; Zeddies M
    J Biomed Mater Res A; 2009 Aug; 90(2):487-95. PubMed ID: 18563809
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Enhancement of active corrosion protection via combination of inhibitor-loaded nanocontainers.
    Tedim J; Poznyak SK; Kuznetsova A; Raps D; Hack T; Zheludkevich ML; Ferreira MG
    ACS Appl Mater Interfaces; 2010 May; 2(5):1528-35. PubMed ID: 20455547
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.