These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 16092347)

  • 1. Interstitial Doppler optical coherence tomography.
    Yang VX; Mao YX; Munce N; Standish B; Kucharczyk W; Marcon NE; Wilson BC; Vitkin IA
    Opt Lett; 2005 Jul; 30(14):1791-3. PubMed ID: 16092347
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility of interstitial Doppler optical coherence tomography for in vivo detection of microvascular changes during photodynamic therapy.
    Li H; Standish BA; Mariampillai A; Munce NR; Mao Y; Chiu S; Marcon NE; Wilson BC; Vitkin A; Yang VX
    Lasers Surg Med; 2006 Sep; 38(8):754-61. PubMed ID: 16927368
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantifying labial blood flow using optical Doppler tomography.
    Otis LL; Piao D; Gibson CW; Zhu Q
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2004 Aug; 98(2):189-94. PubMed ID: 15316546
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Paired-angle-rotation scanning optical coherence tomography forward-imaging probe.
    Wu J; Conry M; Gu C; Wang F; Yaqoob Z; Yang C
    Opt Lett; 2006 May; 31(9):1265-7. PubMed ID: 16642080
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemoglobin contrast in magnetomotive optical Doppler tomography.
    Kim J; Oh J; Milner TE; Nelson JS
    Opt Lett; 2006 Mar; 31(6):778-80. PubMed ID: 16544621
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Integrated intravascular optical coherence tomography ultrasound imaging system.
    Yin J; Yang HC; Li X; Zhang J; Zhou Q; Hu C; Shung KK; Chen Z
    J Biomed Opt; 2010; 15(1):010512. PubMed ID: 20210424
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-penetration swept source Doppler optical coherence angiography by fully numerical phase stabilization.
    Hong YJ; Makita S; Jaillon F; Ju MJ; Min EJ; Lee BH; Itoh M; Miura M; Yasuno Y
    Opt Express; 2012 Jan; 20(3):2740-60. PubMed ID: 22330511
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel combined miniature optical coherence tomography ultrasound probe for in vivo intravascular imaging.
    Yin J; Li X; Jing J; Li J; Mukai D; Mahon S; Edris A; Hoang K; Shung KK; Brenner M; Narula J; Zhou Q; Chen Z
    J Biomed Opt; 2011 Jun; 16(6):060505. PubMed ID: 21721799
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time digital signal processing-based optical coherence tomography and Doppler optical coherence tomography.
    Schaefer AW; Reynolds JJ; Marks DL; Boppart SA
    IEEE Trans Biomed Eng; 2004 Jan; 51(1):186-90. PubMed ID: 14723509
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fiber-optic-bundle-based optical coherence tomography.
    Xie T; Mukai D; Guo S; Brenner M; Chen Z
    Opt Lett; 2005 Jul; 30(14):1803-5. PubMed ID: 16092351
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Linear optical coherence tomography system with a downconverted fringe pattern.
    Koch P; Hüttmann G; Schleiermacher H; Eichholz J; Koch E
    Opt Lett; 2004 Jul; 29(14):1644-6. PubMed ID: 15309846
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dispersion compensation in high-speed optical coherence tomography by acousto-optic modulation.
    Xie T; Wang Z; Pan Y
    Appl Opt; 2005 Jul; 44(20):4272-80. PubMed ID: 16045215
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A dual-modality probe utilizing intravascular ultrasound and optical coherence tomography for intravascular imaging applications.
    Yang HC; Yin J; Hu C; Cannata J; Zhou Q; Zhang J; Chen Z; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Dec; 57(12):2839-43. PubMed ID: 21156380
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Linear optical coherence tomography system with extended measurement range.
    Koch P; Hellemanns V; Hüttmann G
    Opt Lett; 2006 Oct; 31(19):2882-4. PubMed ID: 16969410
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Doppler optical coherence tomography with a micro-electro-mechanical membrane mirror for high-speed dynamic focus tracking.
    Yang VX; Mao Y; Standish BA; Munce NR; Chiu S; Burnes D; Wilson BC; Vitkin IA; Himmer PA; Dickensheets DL
    Opt Lett; 2006 May; 31(9):1262-4. PubMed ID: 16642079
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Parabolic BM-scan technique for full range Doppler spectral domain optical coherence tomography.
    Jaillon F; Makita S; Yabusaki M; Yasuno Y
    Opt Express; 2010 Jan; 18(2):1358-72. PubMed ID: 20173963
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Low-voltage polymer-based scanning cantilever for in vivo optical coherence tomography.
    Wang Y; Bachman M; Li GP; Guo S; Wong BJ; Chen Z
    Opt Lett; 2005 Jan; 30(1):53-5. PubMed ID: 15648635
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography.
    Sharma U; Kang JU
    Rev Sci Instrum; 2007 Nov; 78(11):113102. PubMed ID: 18052460
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Phase-referenced Doppler optical coherence tomography in scattering media.
    Pedersen CJ; Yazdanfar S; Westphal V; Rollins AM
    Opt Lett; 2005 Aug; 30(16):2125-7. PubMed ID: 16127931
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Visualization of microvasculature by dual-beam phase-resolved Doppler optical coherence tomography.
    Zotter S; Pircher M; Torzicky T; Bonesi M; Götzinger E; Leitgeb RA; Hitzenberger CK
    Opt Express; 2011 Jan; 19(2):1217-27. PubMed ID: 21263663
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.