BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 16097648)

  • 1. Preparation, radiochemical purity control and stability of 99mTc-mertiatide (Mag-3).
    van Hemert FJ; van Lenthe H; Schimmel KJ; van Eck-Smit BL
    Ann Nucl Med; 2005 Jun; 19(4):345-9. PubMed ID: 16097648
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preparation of 99mTc-MAG3: radiochemical purity is affected by the residence time of sodium chloride injection in a three-part syringe.
    Waight CC; Beattie LA; O'Brien LM; Millar AM
    Nucl Med Commun; 2006 Feb; 27(2):197-200. PubMed ID: 16404235
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of solvent flow rate in mini-column testing of 99mTc-mertiatide.
    Ponto JA
    J Nucl Med Technol; 2005 Dec; 33(4):232-3. PubMed ID: 16322124
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect on radiochemical purity of modifications to the method of preparation and dilution of 99mTc-sestamibi.
    Cooper M; Dustan K; Rotureau L
    Nucl Med Commun; 2006 May; 27(5):455-60. PubMed ID: 16609357
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preparation of 99Tcm-MAG3: no confirmation that sodium chloride injections from plastic containers affect radiochemical purity.
    Millar AM; O'Brien LM
    Nucl Med Commun; 1998 May; 19(5):475-7. PubMed ID: 9853337
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Miniaturized Radiochemical Purity Testing for
    Fuente A; Zanca R; Boni R; Cataldi AG; Sollini M; Lazzeri E; Mariani G; Erba PA
    J Nucl Med Technol; 2017 Sep; 45(3):236-240. PubMed ID: 28705928
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid determination of the radiochemical purity of 99mTc-antimony trisulfide colloid prepared by standard and alternative heating methods.
    Smyth DR
    J Nucl Med Technol; 2006 Sep; 34(3):174-8. PubMed ID: 16951287
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simplified method for determining the radiochemical purity of 99mTc-MAG3.
    Seetharaman S; Ballinger JR; Sosabowski MH
    J Nucl Med Technol; 2006 Sep; 34(3):179-83. PubMed ID: 16951288
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An investigation of factors that might influence the radiochemical purity and stability of 99mTc-MAG3.
    Millar AM; O'Brien LM
    Eur J Nucl Med; 1990; 16(8-10):615-9. PubMed ID: 2143474
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quality control of instant kit 99mTc-mercapto acetyl triglycine with inter- and intra-operator measurements.
    Bozkurt MF; Kiratli PO; Konyali D; Metin F
    Hell J Nucl Med; 2009; 12(1):59-62. PubMed ID: 19330186
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The radiolabeling property of oligonucleotide with 99mTc using NHS-MAG3 as a chelator].
    Zhang C; Tan TZ; Kuang AR; Li YC; Zheng JG; Pan WM
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2004 Mar; 35(2):169-71. PubMed ID: 15071906
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Preparation and quality control of 99mTc labeled MDR1 oligonucleotide DNAs].
    Fan C; Hnatowich DJ
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Jun; 25(3):712-5. PubMed ID: 18693462
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of 99mTc-MAG3-annexin V: influence of the chelate on in vitro and in vivo properties in mice.
    Vanderheyden JL; Liu G; He J; Patel B; Tait JF; Hnatowich DJ
    Nucl Med Biol; 2006 Jan; 33(1):135-44. PubMed ID: 16459269
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technetium-99m DTPA dimethyl ester: a renal function imaging agent. Comparative studies in animals with technetium-99m mercaptoacetyl triglycine and 131I-ortho-iodohippurate.
    Bhowal K; Bhattacharyya S; Majumdar A; Giri C; Vanaja R; Ramamoorthy N; Ganguly S; Sarkar BR; Banerjee S; Chatterjee Debnath M
    Nucl Med Commun; 2003 May; 24(5):583-95. PubMed ID: 12717078
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the hepatobiliary excretion of technetium-99m-MAG3 and reconstitution factors affecting radiochemical purity.
    Shattuck LA; Eshima D; Taylor AT; Anderson TL; Graham DL; Latino FA; Payne SE
    J Nucl Med; 1994 Feb; 35(2):349-55. PubMed ID: 8295009
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of SepPak and high-performance liquid chromatography as techniques for measuring the radiochemical purity of 99mTc-MAG3.
    Millar AM; Hesslewood SR
    Nucl Med Commun; 2004 Oct; 25(10):1049-51. PubMed ID: 15381873
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of alternative methods of preparing 99mTc-MAG3.
    Seetharaman S; Sosabowski MH; Ballinger JR
    Appl Radiat Isot; 2007 Nov; 65(11):1240-3. PubMed ID: 17434313
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of alternative reconstitution procedures on the labelling efficiency and in vitro stability of 99Tcm-labelled radiopharmaceuticals.
    Bogsrud TV; Chen MN; Herold TJ; Mahoney DW; Hung JC
    Nucl Med Commun; 1999 Jan; 20(1):61-5. PubMed ID: 9949414
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quality control on radiochemical purity in Technetium-99m radiopharmaceuticals labelling: three years of experience on 2280 procedures.
    Maioli C; Luciniani G; Strinchini A; Tagliabue L; Del Sole A
    Acta Biomed; 2017 Apr; 88(1):49-56. PubMed ID: 28467334
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of the radiochemical purity of (99m) Tc medronate injection by thin layer chromatography on iTLC-SG: effect of medronate concentration on the value measured.
    Cunnane CM; O'Brien LM; Waight LA; Millar AM
    J Labelled Comp Radiopharm; 2013 May; 56(5):301-4. PubMed ID: 24285375
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.