These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 1609928)

  • 1. Whitacre 22-gauge spinal needle in young patients.
    Lynch J
    Anaesth Intensive Care; 1992 Feb; 20(1):119-20. PubMed ID: 1609928
    [No Abstract]   [Full Text] [Related]  

  • 2. Post-dural puncture headache in young orthopaedic in-patients: comparison of a 0.33 mm (29-gauge) Quincke-type with a 0.7 mm (22-gauge) Whitacre spinal needle in 200 patients.
    Lynch J; Arhelger S; Krings-Ernst I
    Acta Anaesthesiol Scand; 1992 Jan; 36(1):58-61. PubMed ID: 1539481
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of the 25-gauge Whitacre with the 24-gauge Sprotte spinal needle for elective caesarean section: cost implications.
    Campbell DC; Douglas MJ; Pavy TJ; Merrick P; Flanagan ML; McMorland GH
    Can J Anaesth; 1993 Dec; 40(12):1131-5. PubMed ID: 8281588
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of 26-gauge Atraucan and 25-gauge Whitacre needles: insertion characteristics and complications.
    Sharma SK; Gambling DR; Joshi GP; Sidawi JE; Herrera ER
    Can J Anaesth; 1995 Aug; 42(8):706-10. PubMed ID: 7586110
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Post-dural puncture headache in young adults: comparison of two small-gauge spinal catheters with different needle design.
    Gosch UW; Hueppe M; Hallschmid M; Born J; Schmucker P; Meier T
    Br J Anaesth; 2005 May; 94(5):657-61. PubMed ID: 15722381
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lower incidence of postdural puncture headache using whitacre spinal needles after spinal anesthesia: A meta-analysis.
    Zhang D; Chen L; Chen X; Wang X; Li Y; Ning G; Feng S
    Headache; 2016 Mar; 56(3):501-10. PubMed ID: 26952012
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Postdural puncture headache after spinal anaesthesia in young orthopaedic outpatients using 27-g needles.
    Despond O; Meuret P; Hemmings G
    Can J Anaesth; 1998 Nov; 45(11):1106-9. PubMed ID: 10021962
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dural tissue trauma and cerebrospinal fluid leak after epidural needle puncture: effect of needle design, angle, and bevel orientation.
    Angle PJ; Kronberg JE; Thompson DE; Ackerley C; Szalai JP; Duffin J; Faure P
    Anesthesiology; 2003 Dec; 99(6):1376-82. PubMed ID: 14639152
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fluid flow through dural puncture sites. An in vitro comparison of needle point types.
    Cruickshank RH; Hopkinson JM
    Anaesthesia; 1989 May; 44(5):415-8. PubMed ID: 2742103
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High success rate and low incidence of headache and neurological symptoms with two spinal needle designs in children.
    Kokki H; Turunen M; Heikkinen M; Reinikainen M; Laisalmi M
    Acta Anaesthesiol Scand; 2005 Oct; 49(9):1367-72. PubMed ID: 16146477
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Postdural puncture headache and back pain after spinal anesthesia with 27-gauge Quincke and 26-gauge Atraucan needles.
    Schultz AM; Ulbing S; Kaider A; Lehofer F
    Reg Anesth; 1996; 21(5):461-4. PubMed ID: 8896009
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Comparison of two 27-G-caliber needles for spinal anesthesia. Study of 1,555 patients].
    de Diego Fernández R; Tisner Madrid ML; Cabrerizo Torrente P; Sanjoaquín Mur T
    Rev Esp Anestesiol Reanim; 2003 Apr; 50(4):182-7. PubMed ID: 12825306
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Insertion characteristics and complications of a new spinal needle 26-gauge Atraucan].
    Sakuramoto C
    Masui; 1997 Aug; 46(8):1130-3. PubMed ID: 9411036
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Headache after dural puncture in young patients. Prospective study of 611 cases using a 24-gauge "pencil-point" needle].
    Echevarría M; Caba F; Cruz A; Martínez D; Olmedo L; Mato M; Rodríguez R
    Rev Esp Anestesiol Reanim; 1993; 40(6):376-7. PubMed ID: 8134683
    [No Abstract]   [Full Text] [Related]  

  • 15. Spinal anesthesia in outpatient knee surgery: 22-gauge versus 25-gauge Sprotte needle.
    Pittoni G; Toffoletto F; Calcarella G; Zanette G; Giron GP
    Anesth Analg; 1995 Jul; 81(1):73-9. PubMed ID: 7598286
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The relief of postspinal headache using the Whitacre cannula. Experimental studies].
    Kreuscher H; Sandmann G
    Reg Anaesth; 1989 May; 12(3):43-5. PubMed ID: 2772271
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Postdural puncture headache: a randomized prospective comparison of the 24 gauge Sprotte and the 27 gauge Quincke needles in young patients.
    Wiesel S; Tessler MJ; Easdown LJ
    Can J Anaesth; 1993 Jul; 40(7):607-11. PubMed ID: 8403134
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Whitacre or Quincke needles--does it really matter.
    Eriksson AL; Hallén B; Lagerkranser M; Persson E; Sköldefors E
    Acta Anaesthesiol Scand Suppl; 1998; 113():17-20. PubMed ID: 9932114
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spinal anaesthesia--the current trend towards narrow gauge atraumatic (pencil point) needles. Case reports and review.
    Hoskin MF
    Anaesth Intensive Care; 1998 Feb; 26(1):96-106. PubMed ID: 9513676
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Incidence of postdural puncture headache and backache, and success rate of dural puncture: comparison of two spinal needle designs.
    Pan PH; Fragneto R; Moore C; Ross V
    South Med J; 2004 Apr; 97(4):359-63. PubMed ID: 15108829
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.