276 related articles for article (PubMed ID: 1609945)
21. Predicting the size of a double-lumen endobronchial tube based on tracheal diameter.
Chow MY; Liam BL; Lew TW; Chelliah RY; Ong BC
Anesth Analg; 1998 Jul; 87(1):158-60. PubMed ID: 9661566
[TBL] [Abstract][Full Text] [Related]
22. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.
Sitzwohl C; Langheinrich A; Schober A; Krafft P; Sessler DI; Herkner H; Gonano C; Weinstabl C; Kettner SC
BMJ; 2010 Nov; 341():c5943. PubMed ID: 21062875
[TBL] [Abstract][Full Text] [Related]
23. A logical approach to the selection and insertion of double-lumen tubes.
Russell WJ
Curr Opin Anaesthesiol; 2008 Feb; 21(1):37-40. PubMed ID: 18195607
[TBL] [Abstract][Full Text] [Related]
24. Is it possible to improve the shape of right double-lumen endobronchial tubes?
Mercier FJ; Fischler M
J Cardiothorac Vasc Anesth; 1995 Apr; 9(2):236. PubMed ID: 7780085
[No Abstract] [Full Text] [Related]
25. A comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus.
Hannallah MS; Gharagozloo F; Gomes MN; Chase GA
Anesth Analg; 1998 Nov; 87(5):1027-31. PubMed ID: 9806676
[TBL] [Abstract][Full Text] [Related]
26. Displacement of the double-lumen endobronchial tube can be detected by bronchial cuff pressure change.
Araki K; Nomura R; Urushibara R; Yoshikawa Y; Hatano Y
Anesth Analg; 1997 Jun; 84(6):1349-53. PubMed ID: 9174319
[TBL] [Abstract][Full Text] [Related]
27. Positive pressure ventilation in a patient with a right upper lobar bronchocutaneous fistula: right upper bronchus occlusion using the cuff of a left-sided double lumen endobronchial tube.
Omori C; Toyama H; Takei Y; Ejima Y; Yamauchi M
J Anesth; 2017 Aug; 31(4):627-630. PubMed ID: 28315041
[TBL] [Abstract][Full Text] [Related]
28. The distance between the carina and the distal margin of the right upper lobe orifice measured by computerised tomography as a guide to right-sided double-lumen endobronchial tube use.
Kim JH; Park SH; Han SH; Nahm FS; Jung CK; Kim KM
Anaesthesia; 2013 Jul; 68(7):700-5. PubMed ID: 23656604
[TBL] [Abstract][Full Text] [Related]
29. Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter.
Chow MY; Liam BL; Thng CH; Chong BK
Anesth Analg; 1999 Feb; 88(2):302-5. PubMed ID: 9972745
[TBL] [Abstract][Full Text] [Related]
30. The relationship among bronchial blocker cuff inflation volume, proximal airway pressure, and seal of the bronchial blocker cuff.
Benumof JL; Gaughan SD; Ozaki G
J Cardiothorac Vasc Anesth; 1992 Aug; 6(4):404-8. PubMed ID: 1498294
[TBL] [Abstract][Full Text] [Related]
31. Endobronchial intubation causes an immediate increase in peak inflation pressure in pediatric patients.
Campos C; Naguib SS; Chuang AZ; Lemak NA; Khalil SN
Anesth Analg; 1999 Feb; 88(2):268-70. PubMed ID: 9972739
[TBL] [Abstract][Full Text] [Related]
32. The impact of head position on the cuff and tube tip position of preformed oral tracheal tubes in young children.
Jordi Ritz EM; Von Ungern-Sternberg BS; Keller K; Frei FJ; Erb TO
Anaesthesia; 2008 Jun; 63(6):604-9. PubMed ID: 18477271
[TBL] [Abstract][Full Text] [Related]
33. The single-connector technique for initial placement of double-lumen tubes.
Pfitzner J; Alexander HI; Hung PK
Anaesth Intensive Care; 2004 Oct; 32(5):685-92. PubMed ID: 15535496
[TBL] [Abstract][Full Text] [Related]
34. The Papworth BiVent tube: a new device for lung isolation.
Ghosh S; Falter F; Goldsmith K; Arrowsmith JE
Anaesthesia; 2008 Sep; 63(9):996-1000. PubMed ID: 18540927
[TBL] [Abstract][Full Text] [Related]
35. [Successful One-lung Ventilation with a Right-sided Double-lumen Tube in a Patient with a Right Upper Tracheal Bronchus, who Underwent Left Pneumonectomy for Left Hilar Lung Cancer].
Kawagoe I; Kohchiyama T; Hayashida M; Satoh D; Suzuki K; Inada E
Masui; 2016 Jun; 65(6):594-8. PubMed ID: 27483653
[TBL] [Abstract][Full Text] [Related]
36. [Accidental left bronchial intubation with Parker Flex-Tip Tube].
Kitamura S; Kawano T; Yokoyama M
Masui; 2013 Jun; 62(6):678-81. PubMed ID: 23814990
[TBL] [Abstract][Full Text] [Related]
37. A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic Surgery.
Heir JS; Guo SL; Purugganan R; Jackson TA; Sekhon AK; Mirza K; Lasala J; Feng L; Cata JP
J Cardiothorac Vasc Anesth; 2018 Feb; 32(1):267-274. PubMed ID: 29074128
[TBL] [Abstract][Full Text] [Related]
38. The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning.
Desiderio DP; Burt M; Kolker AC; Fischer ME; Reinsel R; Wilson RS
J Cardiothorac Vasc Anesth; 1997 Aug; 11(5):595-8. PubMed ID: 9263092
[TBL] [Abstract][Full Text] [Related]
39. Tube tip and cuff position using different strategies for placement of currently available paediatric tracheal tubes.
Kemper M; Imach S; Buehler PK; Thomas J; Dave M; Weiss M
Br J Anaesth; 2018 Aug; 121(2):490-495. PubMed ID: 30032890
[TBL] [Abstract][Full Text] [Related]
40. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients.
Kimura T; Suzuki A; Mimuro S; Makino H; Sato S
Paediatr Anaesth; 2012 Dec; 22(12):1185-90. PubMed ID: 22928677
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]