131 related articles for article (PubMed ID: 16099932)
1. Immunoassay interference by a commonly used blood collection tube additive, the organosilicone surfactant silwet L-720.
Bowen RA; Chan Y; Ruddel ME; Hortin GL; Csako G; Demosky SJ; Remaley AT
Clin Chem; 2005 Oct; 51(10):1874-82. PubMed ID: 16099932
[TBL] [Abstract][Full Text] [Related]
2. Effect of blood collection tubes on total triiodothyronine and other laboratory assays.
Bowen RA; Chan Y; Cohen J; Rehak NN; Hortin GL; Csako G; Remaley AT
Clin Chem; 2005 Feb; 51(2):424-33. PubMed ID: 15576427
[TBL] [Abstract][Full Text] [Related]
3. Additive-aggravated assays: an authoritative answer.
Kricka LJ; Park JY
Clin Chem; 2005 Oct; 51(10):1767. PubMed ID: 16189376
[No Abstract] [Full Text] [Related]
4. Differential effect of blood collection tubes on total free fatty acids (FFA) and total triiodothyronine (TT3) concentration: a model for studying interference from tube constituents.
Bowen RA; Vu C; Remaley AT; Hortin GL; Csako G
Clin Chim Acta; 2007 Mar; 378(1-2):181-93. PubMed ID: 17234171
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.
Kocijancic M; Cargonja J; Delic-Knezevic A
Biochem Med (Zagreb); 2014; 24(3):368-75. PubMed ID: 25351355
[TBL] [Abstract][Full Text] [Related]
6. The Usage of Separating Gel Vacuum Tube with Different IgG Concentration.
Wang ZE; Song XF; Zou JW; Duan WB; Wang Y; Zhang BC; Wu H
Ann Clin Lab Sci; 2015; 45(4):438-40. PubMed ID: 26275696
[TBL] [Abstract][Full Text] [Related]
7. Comparison of Bayer Advia Centaur immunoassay results obtained on samples collected in four different Becton Dickinson Vacutainer tubes.
Morovat A; James TS; Cox SD; Norris SG; Rees MC; Gales MA; Taylor RP
Ann Clin Biochem; 2006 Nov; 43(Pt 6):481-7. PubMed ID: 17132279
[TBL] [Abstract][Full Text] [Related]
8. Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube.
Shin S; Oh J; Park HD
Ann Lab Med; 2021 Jan; 41(1):114-119. PubMed ID: 32829587
[TBL] [Abstract][Full Text] [Related]
9. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.
Arslan FD; Karakoyun I; Basok BI; Aksit MZ; Baysoy A; Ozturk YK; Guclu YA; Duman C
Biochem Med (Zagreb); 2017 Oct; 27(3):030706. PubMed ID: 28900369
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes.
Chance J; Berube J; Vandersmissen M; Blanckaert N
Clin Chem Lab Med; 2009; 47(3):358-61. PubMed ID: 19676149
[TBL] [Abstract][Full Text] [Related]
11. Interferences from blood collection tube components on clinical chemistry assays.
Bowen RA; Remaley AT
Biochem Med (Zagreb); 2014; 24(1):31-44. PubMed ID: 24627713
[TBL] [Abstract][Full Text] [Related]
12. Assessment of Becton Dickinson Plain and Serum Separator Tubes in Measurement of 25-Hydroxyvitamin D3 (25OHD3) by HPLC and Immunoassay Methods.
Borai A; Bahijri S; Livingstone C; Nawajha M; Bawazeer A; Baarmah Z; Shanaa A; Kadam I; Abdelaal M
J Clin Lab Anal; 2016 Jan; 30(1):32-5. PubMed ID: 25278163
[TBL] [Abstract][Full Text] [Related]
13. [Comparison of two new plastic tubes (Sekisui INSEPACK and Green Cross Green Vac-Tube) with BD Vacutainer tubes for 49 analytes].
Oh SH; Ki CS
Korean J Lab Med; 2007 Feb; 27(1):69-75. PubMed ID: 18094554
[TBL] [Abstract][Full Text] [Related]
14. Comparison of Improvacuter™ tubes with BD Vacutainer™ tubes for various hormones in the aspects of stability and influence of gel separators.
Zungun C; Yılmaz FM; Boru EG; Topcuoglu C
Clin Chem Lab Med; 2015 Feb; 53(2):231-8. PubMed ID: 25153600
[TBL] [Abstract][Full Text] [Related]
15. Positive interference in lithium determinations from clot activator in collection container.
Sampson M; Ruddel M; Albright S; Elin RJ
Clin Chem; 1997 Apr; 43(4):675-9. PubMed ID: 9105272
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of BD Barricor™ Plasma Blood Collection Tube for Biochemical Tests.
Kösem A; Topçuoğlu C; Sezer S; Cevher ŞK; Yenigün EC; Dede F; Turhan T
Clin Lab; 2019 Dec; 65(12):. PubMed ID: 31850716
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of the chemiluminescence immunoassays for the measurement of troponin I, myoglobin and CK-MB using the IMMULITE system in comparison to other measuring systems.
Lestin M; Hergert M; Lestin HG; Brinker C; Storm H; Kuhrt E; Kuhrt B; Lambrecht HG; Kühnel W
Clin Lab; 2002; 48(3-4):211-21. PubMed ID: 11934224
[TBL] [Abstract][Full Text] [Related]
18. "Inert" formulation ingredients with activity: toxicity of trisiloxane surfactant solutions to twospotted spider mites (Acari: Tetranychidae).
Cowles RS; Cowles EA; McDermott AM; Ramoutar D
J Econ Entomol; 2000 Apr; 93(2):180-8. PubMed ID: 10826161
[TBL] [Abstract][Full Text] [Related]
19. Minimizing nonspecific protein adsorption in liquid crystal immunoassays by using surfactants.
Zhang W; Ang WT; Xue CY; Yang KL
ACS Appl Mater Interfaces; 2011 Sep; 3(9):3496-500. PubMed ID: 21815616
[TBL] [Abstract][Full Text] [Related]
20. Comparison of Becton Dickinson Vacutainer rapid serum tube with the serum separator tube for routine chemistry and immunoassay tests.
Yan R; Lou A; Watts G; Tarr H; Smith H; Kinney L; Chen Y
J Clin Pathol; 2014 Jul; 67(7):599-604. PubMed ID: 24687321
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]