These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. [Hemodynamic monitoring in the intensive care unit: pulmonary artery catheter versus PiCCO]. Gassanov N; Caglayan E; Nia A; Erdmann E; Er F Dtsch Med Wochenschr; 2011 Feb; 136(8):376-80. PubMed ID: 21332037 [TBL] [Abstract][Full Text] [Related]
6. Review article: Non-invasive assessment of cardiac output with portable continuous-wave Doppler ultrasound. Meyer S; Todd D; Wright I; Gortner L; Reynolds G Emerg Med Australas; 2008 Jun; 20(3):201-8. PubMed ID: 18400002 [TBL] [Abstract][Full Text] [Related]
7. Clinical validation of the non-invasive cardiac output monitor USCOM-1A in critically ill patients. van Lelyveld-Haas LE; van Zanten AR; Borm GF; Tjan DH Eur J Anaesthesiol; 2008 Nov; 25(11):917-24. PubMed ID: 18652712 [TBL] [Abstract][Full Text] [Related]
8. [The basic ideas about the use of the Swan-Ganz catheter]. Bassi IM; Lazzari C; Zanela T Rev Gaucha Enferm; 1990 Jan; 11(1):52-7. PubMed ID: 2099509 [TBL] [Abstract][Full Text] [Related]
9. Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters? Perrino AC Yale J Biol Med; 1993; 66(5):397-413. PubMed ID: 7825341 [TBL] [Abstract][Full Text] [Related]
10. Cardiac output wireless wearable devices are maybe not interchangeable with Swan-Ganz catheters yet, but the question is… have they reached mininvasive tools? Vetrugno L; Maggiore SM; Deana C; Bellini V; Bignami EG J Clin Monit Comput; 2024 Aug; 38(4):869-871. PubMed ID: 38700742 [No Abstract] [Full Text] [Related]
11. Erroneous cardiac output measurement due to loop formation of a Swan-Ganz catheter in the pulmonary artery. Schummer W; Schummer C; Schummer C J Clin Anesth; 2004 May; 16(3):235-6. PubMed ID: 15217669 [No Abstract] [Full Text] [Related]
12. Continuous invasive cardiac output monitoring--the Baxter/Edwards Critical-Care Swan Ganz IntelliCath and Viligance system. Munro HM; Wood CE; Taylor BL; Smith GB Clin Intensive Care; 1994; 5(2):52-5. PubMed ID: 10147254 [TBL] [Abstract][Full Text] [Related]
15. A modified setup for cardiac output determination in case of an inaccessible pulmonary artery catheter. Duong TT; Bourke DL; Willock MM J Cardiothorac Anesth; 1988 Apr; 2(2):269-70. PubMed ID: 17171923 [No Abstract] [Full Text] [Related]
16. [Discussion of the pulmonary artery catheter]. Hempelmann G Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 May; 32(5):269-70. PubMed ID: 9264613 [No Abstract] [Full Text] [Related]
17. Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system. Thierry S; Thebert D; Brocas E; Razzaghi F; Van De Louw A; Loisance D; Teboul JL Intensive Care Med; 2003 Nov; 29(11):2096-9. PubMed ID: 13680117 [TBL] [Abstract][Full Text] [Related]
18. Non-invasive cardiac output monitoring. Hett DA; Jonas MM Intensive Crit Care Nurs; 2004 Apr; 20(2):103-8. PubMed ID: 15072778 [TBL] [Abstract][Full Text] [Related]