BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 1611735)

  • 1. Biomechanics of the Ilizarov fixator for fracture fixation.
    Calhoun JH; Li F; Ledbetter BR; Gill CA
    Clin Orthop Relat Res; 1992 Jul; (280):15-22. PubMed ID: 1611735
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A biomechanical analysis of the Ilizarov external fixator.
    Fleming B; Paley D; Kristiansen T; Pope M
    Clin Orthop Relat Res; 1989 Apr; (241):95-105. PubMed ID: 2924484
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators.
    Podolsky A; Chao EY
    Clin Orthop Relat Res; 1993 Aug; (293):61-70. PubMed ID: 8339510
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanics of the Ilizarov external fixator.
    Kummer FJ
    Bull Hosp Jt Dis Orthop Inst; 1989; 49(2):140-7. PubMed ID: 2557936
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rigidity of half-pins for the Ilizarov external fixator.
    Calhoun JH; Li F; Bauford WL; Lehman T; Ledbetter BR; Lowery R
    Bull Hosp Jt Dis; 1992; 52(1):21-6. PubMed ID: 1422438
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transfixion wire positioning within the bone: an option to control proximal tibia external fixation stiffness.
    Antoci V; Raney EM; Antoci V; Voor MJ; Roberts CS
    J Pediatr Orthop; 2006; 26(4):466-70. PubMed ID: 16791063
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanics of the Ilizarov external fixator.
    Kummer FJ
    Clin Orthop Relat Res; 1992 Jul; (280):11-4. PubMed ID: 1611730
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical evaluation of external fixators used in limb lengthening.
    Paley D; Fleming B; Catagni M; Kristiansen T; Pope M
    Clin Orthop Relat Res; 1990 Jan; (250):50-7. PubMed ID: 2293944
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of wire configuration on the stability of the Ilizarov external fixator.
    Orbay GL; Frankel VH; Kummer FJ
    Clin Orthop Relat Res; 1992 Jun; (279):299-302. PubMed ID: 1600668
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hybrid external fixation of distal tibial fractures: new strategy to place pins and wires without penetrating the anterior compartment.
    Oh JK; Lee JJ; Jung DY; Kim BJ; Oh CW
    Arch Orthop Trauma Surg; 2004 Oct; 124(8):542-6. PubMed ID: 15340748
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical estimation of ilizarov fixator axial stiffness based on wire and half pin contributions.
    Waanders NA; Lawton JN; Steen H; Goulet JA; Goldstein SA
    Bull Hosp Jt Dis; 1993-1995; 53(4):10-2. PubMed ID: 8829588
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Initial modifications of the ring fixator apparatus].
    Schümann U; Wolter D; Schmidt HG
    Unfallchirurg; 1992 Nov; 95(11):593-5. PubMed ID: 1480977
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The use of a circular external skeletal fixation device for the management of long bone osteotomies in large ruminants: an experimental study.
    Aithal HP; Singh GR; Hoque M; Maiti SK; Kinjavdekar P; Pawde AM; Setia HC;
    J Vet Med A Physiol Pathol Clin Med; 2004 Aug; 51(6):284-93. PubMed ID: 15485564
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Control of interfragmentary micromotion in Ilizarov distractional osteogenesis.
    Wolfson N; Galpin RD; Hearn TC; Willis RB
    Bull Hosp Jt Dis; 1992; 52(1):36-8. PubMed ID: 1422440
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of wire plane tilt and olive wires on proximal tibia fracture fragment stability and fracture site motion.
    Voor MJ; Antoci V; Antoci V; Roberts CS
    J Biomech; 2005 Mar; 38(3):537-41. PubMed ID: 15652552
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tensioning technique and fixator stability of a circular external fixator with threaded fine wires.
    Rickman M; Saleh M; Yang L
    J Biomech; 2006; 39(3):544-50. PubMed ID: 16389095
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Ilisarov ring fixation and its technical application].
    Jürgens C; Schmidt HG; Schümann U; Fink B
    Unfallchirurg; 1992 Nov; 95(11):529-33. PubMed ID: 1480964
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical performance of hybrid Ilizarov external fixator in comparison with Ilizarov circular external fixator.
    Yilmaz E; Belhan O; Karakurt L; Arslan N; Serin E
    Clin Biomech (Bristol, Avon); 2003 Jul; 18(6):518-22. PubMed ID: 12828901
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of transfixion wire crossing angle on the stiffness of fine wire external fixation: a biomechanical study.
    Roberts CS; Antoci V; Antoci V; Voor MJ
    Injury; 2005 Sep; 36(9):1107-12. PubMed ID: 16098336
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reduction in wire tension caused by dynamic loading. An experimental Ilizarov frame study.
    La Russa V; Skallerud B; Klaksvik J; Foss OA
    J Biomech; 2011 May; 44(8):1454-8. PubMed ID: 21453923
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.