These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

77 related articles for article (PubMed ID: 16119492)

  • 1. How well can anaesthetists discriminate pulse oximeter tones?
    Morris RW; Mohacsi PJ
    Anaesth Intensive Care; 2005 Aug; 33(4):497-500. PubMed ID: 16119492
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Sounds of Desaturation: A Survey of Commercial Pulse Oximeter Sonifications.
    Loeb RG; Brecknell B; Sanderson PM
    Anesth Analg; 2016 May; 122(5):1395-403. PubMed ID: 27028772
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of linear and logarithmic auditory tones in pulse oximeters.
    Brown Z; Edworthy J; Sneyd JR; Schlesinger J
    Appl Ergon; 2015 Nov; 51():350-7. PubMed ID: 26154232
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The sounds of saturation.
    Santamore DC; Cleaver TG
    J Clin Monit Comput; 2004 Apr; 18(2):89-92. PubMed ID: 15362270
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Can people hear the pitch change on a variable-pitch pulse oximeter?
    Schulte GT; Block FE
    J Clin Monit; 1992 Jul; 8(3):198-200. PubMed ID: 1494925
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Does the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?
    Kisch-Wedel H; Bernreuter P; Kemming G; Albert M; Zwissler B
    IEEE Trans Biomed Eng; 2009 Sep; 56(9):2271-9. PubMed ID: 19692303
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effectiveness of enhanced pulse oximetry sonifications for conveying oxygen saturation ranges: a laboratory comparison of five auditory displays.
    Paterson E; Sanderson PM; Paterson NAB; Loeb RG
    Br J Anaesth; 2017 Dec; 119(6):1224-1230. PubMed ID: 29045578
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of an enhanced pulse oximeter auditory display: a simulaion study.
    Paterson E; Sanderson PM; Salisbury IS; Burgmann FP; Mohamed I; Loeb RG; Paterson NAB
    Br J Anaesth; 2020 Nov; 125(5):826-834. PubMed ID: 32682554
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of the Nonin 8600V Pulse Oximeter for heart rate and oxygen saturation measurements in rats.
    Bernard SL; An D; Glenny RW
    Contemp Top Lab Anim Sci; 2004 May; 43(3):43-5. PubMed ID: 15174817
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Proof of concept non-invasive estimation of peripheral venous oxygen saturation.
    Khan M; Pretty CG; Amies AC; Balmer J; Banna HE; Shaw GM; Geoffrey Chase J
    Biomed Eng Online; 2017 May; 16(1):60. PubMed ID: 28526082
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical evaluation of pulse oximetry monitors on critically ill patients.
    De Pauw C; Poelaert J; Rolly G; Colardyn F
    Acta Anaesthesiol Belg; 1990; 41(1):33-9. PubMed ID: 2360390
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Noninvasive oximetry in the rat.
    Decker MJ; Conrad KP; Strohl KP
    Biomed Instrum Technol; 1989; 23(3):222-8. PubMed ID: 2752232
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.
    Harris BU; Char DS; Feinstein JA; Verma A; Shiboski SC; Ramamoorthy C
    Pediatr Crit Care Med; 2016 Apr; 17(4):315-20. PubMed ID: 26914626
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Reliability and limitations of pulse oximetry in corrective cyanotic heart surgery].
    Meier-Stauss P; Schmid ER; Weiss BM; König V; Huch R
    Anaesthesist; 1989 Jun; 38(6):302-8. PubMed ID: 2764270
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulse oximetry in newborn infants with birth weights of 620 to 4285 grams receiving dopamine and dobutamine.
    Sardesai S; Durand M; McEvoy C; Johnson C; Maarek JM
    J Perinatol; 1996; 16(1):31-4. PubMed ID: 8869537
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lifebox pulse oximeter implementation in Malawi: evaluation of educational outcomes and impact on oxygen desaturation episodes during anaesthesia.
    Albert V; Mndolo S; Harrison EM; O'Sullivan E; Wilson IH; Walker IA
    Anaesthesia; 2017 Jun; 72(6):686-693. PubMed ID: 28439886
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Novel Pulse Oximetry Sonifications for Neonatal Oxygen Saturation Monitoring: A Laboratory Study.
    Hinckfuss K; Sanderson P; Loeb RG; Liley HG; Liu D
    Hum Factors; 2016 Mar; 58(2):344-59. PubMed ID: 26715687
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving pulse oximetry pitch perception with multisensory perceptual training.
    Schlesinger JJ; Stevenson RA; Shotwell MS; Wallace MT
    Anesth Analg; 2014 Jun; 118(6):1249-53. PubMed ID: 24846194
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Audio spectrum and sound pressure levels vary between pulse oximeters.
    Chandra D; Tessler MJ; Usher J
    Can J Anaesth; 2006 Jan; 53(1):26-32. PubMed ID: 16371606
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.