These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 16126585)

  • 1. Subtraction procedure for powerline interference removing from ECG: improvement for non-multiple sampling.
    Mihov G; Dotsinsky IV; Georgieva TS
    J Med Eng Technol; 2005; 29(5):238-43. PubMed ID: 16126585
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A method for reduction of power line interference in the ECG.
    Mitov IP
    Med Eng Phys; 2004 Dec; 26(10):879-87. PubMed ID: 15567704
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel application of the S-transform in removing powerline interference from biomedical signals.
    Huang CC; Liang SF; Young MS; Shaw FZ
    Physiol Meas; 2009 Jan; 30(1):13-27. PubMed ID: 19039164
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Power-line interference cancellation in ECG signals.
    Dotsinsky I; Stoyanov T
    Biomed Instrum Technol; 2005; 39(2):155-62. PubMed ID: 15810791
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Subtraction of 16.67 Hz railroad net interference from the electrocardiogram: application for automatic external defibrillators.
    Jekova I; Krasteva V
    Physiol Meas; 2005 Dec; 26(6):987-1003. PubMed ID: 16311447
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noise cancellation signal processing method and computer system for improved real-time electrocardiogram artifact correction during MRI data acquisition.
    Odille F; Pasquier C; Abächerli R; Vuissoz PA; Zientara GP; Felblinger J
    IEEE Trans Biomed Eng; 2007 Apr; 54(4):630-40. PubMed ID: 17405370
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Power-line interference detection and suppression in ECG signal processing.
    Lin YD; Hu YH
    IEEE Trans Biomed Eng; 2008 Jan; 55(1):354-7. PubMed ID: 18232382
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A wavelet-based adaptive filter for removing ECG interference in EMGdi signals.
    Zhan C; Yeung LF; Yang Z
    J Electromyogr Kinesiol; 2010 Jun; 20(3):542-9. PubMed ID: 19692270
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A nonlinear adaptive method of elimination of power line interference in ECG signals.
    Ziarani AK; Konrad A
    IEEE Trans Biomed Eng; 2002 Jun; 49(6):540-7. PubMed ID: 12046699
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Real time implementation of genetic algorithm cancellation of sinusoidal noise in ECG using TMS320C50 DSP processor.
    Kumaravel N; Viswanathan SM
    Biomed Sci Instrum; 1999; 35():169-74. PubMed ID: 11143342
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators.
    Dotsinsky I
    Biomed Eng Online; 2005 Nov; 4():65. PubMed ID: 16309558
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adaptive digital notch filter design on the unit circle for the removal of powerline noise from biomedical signals.
    Ferdjallah M; Barr RE
    IEEE Trans Biomed Eng; 1994 Jun; 41(6):529-36. PubMed ID: 7927372
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Application of independent component analysis to ECG cancellation in surface electromyography measurement].
    Cao Y; Chen C; Hu Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Aug; 22(4):686-9. PubMed ID: 16156250
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A review of electrocardiogram filtering.
    Luo S; Johnston P
    J Electrocardiol; 2010; 43(6):486-96. PubMed ID: 20851409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Real time ECG artifact removal for myoelectric prosthesis control.
    Zhou P; Lock B; Kuiken TA
    Physiol Meas; 2007 Apr; 28(4):397-413. PubMed ID: 17395995
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG.
    Hamilton PS
    IEEE Trans Biomed Eng; 1996 Jan; 43(1):105-9. PubMed ID: 8567001
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms.
    Xu L; Zhang D; Wang K
    IEEE Trans Biomed Eng; 2005 Nov; 52(11):1973-5. PubMed ID: 16285403
    [TBL] [Abstract][Full Text] [Related]  

  • 18. What is inside the electrocardiograph?
    Gregg RE; Zhou SH; Lindauer JM; Helfenbein ED; Giuliano KK
    J Electrocardiol; 2008; 41(1):8-14. PubMed ID: 18191652
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Lossless ECG compression algorithm with anti- electromagnetic interference].
    Guan SA
    Zhongguo Yi Liao Qi Xie Za Zhi; 2005 Mar; 29(2):112-4. PubMed ID: 16011116
    [TBL] [Abstract][Full Text] [Related]  

  • 20. ECG signal denoising and baseline wander correction based on the empirical mode decomposition.
    Blanco-Velasco M; Weng B; Barner KE
    Comput Biol Med; 2008 Jan; 38(1):1-13. PubMed ID: 17669389
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.