These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 16130990)

  • 1. Comparison of selenium determination in liver samples by atomic absorption spectroscopy and inductively coupled plasma-mass spectrometry.
    Miksa IR; Buckley CL; Carpenter NP; Poppenga RH
    J Vet Diagn Invest; 2005 Jul; 17(4):331-40. PubMed ID: 16130990
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Selenium determination in plasma/serum by inductively coupled plasma mass spectrometry (ICP-MS): comparison with graphite furnace atomic absorption spectrometry (GF-AAS)].
    Janasik B; Trzcinka-Ochocka M; Brodzka R
    Med Pr; 2011; 62(5):489-98. PubMed ID: 22312963
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Method for measurement of serum copper, zinc and selenium using total reflection X-ray fluorescence spectroscopy on the PICOFOX analyser: Validation and comparison with atomic absorption spectroscopy and inductively coupled plasma mass spectrometry.
    Jeffery J; Frank AR; Hockridge S; Stosnach H; Costelloe SJ
    Ann Clin Biochem; 2019 Jan; 56(1):170-178. PubMed ID: 30056759
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rapid and simple determination of selenium in blood serum by inductively coupled plasma-mass spectrometry (ICP-MS).
    Labat L; Dehon B; Lhermitte M
    Anal Bioanal Chem; 2003 May; 376(2):270-3. PubMed ID: 12677338
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of two methods using atomic absorption spectrometry for determination of selenium in food.
    Matek M; Blanusa M; Grgić J
    Arh Hig Rada Toksikol; 1999 Sep; 50(3):283-8. PubMed ID: 10649844
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A method for low volume and low Se concentration samples and application to paired cerebrospinal fluid and serum samples.
    Michalke B; Grill P; Berthele A
    J Trace Elem Med Biol; 2009; 23(4):243-50. PubMed ID: 19747619
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The correlation between serum selenium and blood selenium in cattle.
    Maas J; Galey FD; Peauroi JR; Case JT; Littlefield ES; Gay CC; Koller LD; Crisman RO; Weber DW; Warner DW
    J Vet Diagn Invest; 1992 Jan; 4(1):48-52. PubMed ID: 1554769
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cloud point extraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the speciation of inorganic selenium in environmental water samples.
    Chen B; Hu B; He M
    Rapid Commun Mass Spectrom; 2006; 20(19):2894-900. PubMed ID: 16941541
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry.
    Grindlay G; Mora J; Gras L; de Loos-Vollebregt MT
    Anal Chim Acta; 2009 Oct; 652(1-2):154-60. PubMed ID: 19786176
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of selenium-containing biological constituents by high-performance liquid chromatography-plasma source mass spectrometry.
    Suzuki KT; Itoh M; Ohmichi M
    J Chromatogr B Biomed Appl; 1995 Apr; 666(1):13-9. PubMed ID: 7655611
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interlaboratory comparison of heavy metal testing in animal diagnostic specimens and feed using inductively coupled plasma-mass spectrometry.
    McGeehan S; Baszler T; Gaskill C; Johnson J; Smith L; Raisbeck M; Schrier N; Harris H; Talcott P
    J Vet Diagn Invest; 2020 Mar; 32(2):291-300. PubMed ID: 32052705
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of trace level of selenium and mercury in photographic emulsions by atomic spectroscopy techniques.
    Magi E; Soggia F; Frache R
    Ann Chim; 2002 Mar; 92(3):229-38. PubMed ID: 12025508
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Method for the determination of total selenium in a wide variety of foods using inductively coupled plasma/mass spectrometry.
    Sullivan D; Zywicki R; Yancey M
    J AOAC Int; 2013; 96(4):786-94. PubMed ID: 24000753
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of chromium, selenium, and molybdenum in a therapeutic diet.
    Lozak A; Sołtyk K; Ostapczuk P; Fijałek Z
    Pharmazie; 2004 Nov; 59(11):824-7. PubMed ID: 15587579
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Total Selenium Quantification in Biological Samples by Inductively Coupled Plasma Mass Spectrometry (ICP-MS).
    Vacchina V; Dumont J
    Methods Mol Biol; 2018; 1661():145-152. PubMed ID: 28917042
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of four analytical techniques based on atomic spectrometry for the determination of total tin in canned foodstuffs.
    Boutakhrit K; Crisci M; Bolle F; Van Loco J
    Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2011 Feb; 28(2):173-9. PubMed ID: 21246429
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Solid phase extraction for the speciation and preconcentration of inorganic selenium in water samples: a review.
    Herrero Latorre C; Barciela García J; García Martín S; Peña Crecente RM
    Anal Chim Acta; 2013 Dec; 804():37-49. PubMed ID: 24267061
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Total selenium and selenomethionine in pharmaceutical yeast tablets: assessment of the state of the art of measurement capabilities through international intercomparison CCQM-P86.
    Goenaga-Infante H; Sturgeon R; Turner J; Hearn R; Sargent M; Maxwell P; Yang L; Barzev A; Pedrero Z; Cámara C; Díaz Huerta V; Fernández Sánchez ML; Sanz-Medel A; Emese K; Fodor P; Wolf W; Goldschmidt R; Vacchina V; Szpunar J; Valiente L; Huertas R; Labarraque G; Davis C; Zeisler R; Turk G; Rizzio E; Mackay LG; Myors RB; Saxby DL; Askew S; Chao W; Jun W
    Anal Bioanal Chem; 2008 Jan; 390(2):629-42. PubMed ID: 17938894
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous determination of Se, trace elements and major elements in Se-rich rice by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) after microwave digestion.
    Wei YH; Zhang JY; Zhang DW; Luo LG; Tu TH
    Food Chem; 2014 Sep; 159():507-11. PubMed ID: 24767089
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Determination of trace selenium in coal by microwave digestion and hydride generation ICP-AES].
    Liu J; Zheng CG; Zhang JY; Xu JY
    Guang Pu Xue Yu Guang Pu Fen Xi; 2004 Mar; 24(3):351-3. PubMed ID: 15759997
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.