211 related articles for article (PubMed ID: 16131888)
1. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?
Back DL; Young DA; Shimmin AJ
Clin Orthop Relat Res; 2005 Sep; 438():177-81. PubMed ID: 16131888
[TBL] [Abstract][Full Text] [Related]
2. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study.
Jacobs JJ; Skipor AK; Patterson LM; Hallab NJ; Paprosky WG; Black J; Galante JO
J Bone Joint Surg Am; 1998 Oct; 80(10):1447-58. PubMed ID: 9801213
[TBL] [Abstract][Full Text] [Related]
3. The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients With Metal-on-Polyethylene Total Hip Arthroplasty.
Kwon YM; MacAuliffe J; Peng Y; Arauz P
J Arthroplasty; 2018 Aug; 33(8):2631-2635. PubMed ID: 29691164
[TBL] [Abstract][Full Text] [Related]
4. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
[TBL] [Abstract][Full Text] [Related]
5. Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty.
Fillingham YA; Della Valle CJ; Bohl DD; Kelly MP; Hall DJ; Pourzal R; Jacobs JJ
J Arthroplasty; 2017 Sep; 32(9S):S272-S277. PubMed ID: 28511949
[TBL] [Abstract][Full Text] [Related]
6. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
[TBL] [Abstract][Full Text] [Related]
7. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
Vendittoli PA; Roy A; Mottard S; Girard J; Lusignan D; Lavigne M
J Bone Joint Surg Br; 2010 Jan; 92(1):12-9. PubMed ID: 20044673
[TBL] [Abstract][Full Text] [Related]
8. Changes in cobalt and chromium levels after metal-on-metal hip resurfacing in young, active Chinese patients.
Yang J; Shen B; Zhou Z; Pei F; Kang P
J Arthroplasty; 2011 Jan; 26(1):65-70, 70.e1. PubMed ID: 20171050
[TBL] [Abstract][Full Text] [Related]
9. One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes.
Lardanchet JF; Taviaux J; Arnalsteen D; Gabrion A; Mertl P
Orthop Traumatol Surg Res; 2012 May; 98(3):265-74. PubMed ID: 22480865
[TBL] [Abstract][Full Text] [Related]
10. The Cobalt/Chromium Ratio Provides Similar Diagnostic Value to a Low Cobalt Threshold in Predicting Adverse Local Tissue Reactions in Patients With Metal-on-Metal Hip Arthroplasty.
Laaksonen I; Galea VP; Donahue GS; Matuszak SJ; Muratoglu O; Malchau H
J Arthroplasty; 2018 Sep; 33(9):3020-3024. PubMed ID: 29716769
[TBL] [Abstract][Full Text] [Related]
11. Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.
Antoniou J; Zukor DJ; Mwale F; Minarik W; Petit A; Huk OL
J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():142-8. PubMed ID: 18676949
[TBL] [Abstract][Full Text] [Related]
12. The Effectiveness of Blood Metal Ions in Identifying Patients with Unilateral Birmingham Hip Resurfacing and Corail-Pinnacle Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris.
Matharu GS; Berryman F; Brash L; Pynsent PB; Treacy RB; Dunlop DJ
J Bone Joint Surg Am; 2016 Apr; 98(8):617-26. PubMed ID: 27098320
[TBL] [Abstract][Full Text] [Related]
13. Cobalt and chromium levels in blood and urine following hip resurfacing arthroplasty with the Conserve Plus implant.
Kim PR; Beaulé PE; Dunbar M; Lee JK; Birkett N; Turner MC; Yenugadhati N; Armstrong V; Krewski D
J Bone Joint Surg Am; 2011 May; 93 Suppl 2():107-17. PubMed ID: 21543699
[TBL] [Abstract][Full Text] [Related]
14. Systemic toxicity related to metal hip prostheses.
Bradberry SM; Wilkinson JM; Ferner RE
Clin Toxicol (Phila); 2014; 52(8):837-47. PubMed ID: 25132471
[TBL] [Abstract][Full Text] [Related]
15. [Assessment of the level of metal ions in the blood of patients after hip resurfacing--preliminary report].
Markuszewski J; Krzyszczuk M; Woźniak W; Kokoszka P; Wierusz-Kozłowska M
Chir Narzadow Ruchu Ortop Pol; 2011; 76(6):332-5. PubMed ID: 22708320
[TBL] [Abstract][Full Text] [Related]
16. Cobalt serum levels differ in well functioning Birmingham resurfacing and Birmingham modular THA.
Renner L; Faschingbauer M; Schmidt-Braekling T; Boettner F
Arch Orthop Trauma Surg; 2016 May; 136(5):715-21. PubMed ID: 26983720
[TBL] [Abstract][Full Text] [Related]
17. Asymptomatic Pseudotumors in Patients with Taper Corrosion of a Dual-Taper Modular Femoral Stem: MARS-MRI and Metal Ion Study.
Kwon YM; Khormaee S; Liow MH; Tsai TY; Freiberg AA; Rubash HE
J Bone Joint Surg Am; 2016 Oct; 98(20):1735-1740. PubMed ID: 27869625
[TBL] [Abstract][Full Text] [Related]
18. Distribution of chromium and cobalt ions in various blood fractions after resurfacing hip arthroplasty.
Walter LR; Marel E; Harbury R; Wearne J
J Arthroplasty; 2008 Sep; 23(6):814-21. PubMed ID: 18534545
[TBL] [Abstract][Full Text] [Related]
19. The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty.
Hothi HS; Berber R; Whittaker RK; Blunn GW; Skinner JA; Hart AJ
J Arthroplasty; 2016 May; 31(5):1123-7. PubMed ID: 26796774
[TBL] [Abstract][Full Text] [Related]
20. What do we know about taper corrosion in total hip arthroplasty?
Jacobs JJ; Cooper HJ; Urban RM; Wixson RL; Della Valle CJ
J Arthroplasty; 2014 Apr; 29(4):668-9. PubMed ID: 24655613
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]