These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 16132874)

  • 1. [Accuracy and precision in the evaluation of computer assisted surgical systems. A definition].
    Strauss G; Hofer M; Korb W; Trantakis C; Winkler D; Burgert O; Schulz T; Dietz A; Meixensberger J; Koulechov K
    HNO; 2006 Feb; 54(2):78-84. PubMed ID: 16132874
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group no. 68.
    Lightstone AW; Benedict SH; Bova FJ; Solberg TD; Stern RL;
    Med Phys; 2005 Jul; 32(7):2380-98. PubMed ID: 16121596
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Target registration and target positioning errors in computer-assisted neurosurgery: proposal for a standardized reporting of error assessment.
    Widmann G; Stoffner R; Sieb M; Bale R
    Int J Med Robot; 2009 Dec; 5(4):355-65. PubMed ID: 19565464
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A technical evaluation of the Nucletron FIRST system: conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations.
    Rivard MJ; Evans DA; Kay I
    J Appl Clin Med Phys; 2005; 6(1):22-50. PubMed ID: 15770195
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Official measurement protocol and accuracy results for an optical surgical navigation system (NPU).
    Wittmann W; Wenger T; Loewe E; Lueth TC
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():1237-40. PubMed ID: 22254540
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The quality of digital mammograms. Development and use of phantoms for optimal safety].
    Schöfer H; Kotsianos D; Wirth S; Britsch S; Reiser M
    Radiologe; 2005 Mar; 45(3):278-85. PubMed ID: 15747150
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Standardization of orthodontic products--does it make sense?
    Sernetz F
    J Orofac Orthop; 2005 Jul; 66(4):307-18. PubMed ID: 16044229
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance measures of ISM-band and conventional telemetry.
    Baker SD; King SW; Welch JP
    IEEE Eng Med Biol Mag; 2004; 23(3):27-36. PubMed ID: 15354992
    [No Abstract]   [Full Text] [Related]  

  • 9. [Improved accuracy and precision of the automated shaver (navigated control) in functional endoscopic sinus surgery].
    Strauss G; Koulechov K; Stopp S; Strauss M; Pankau A; Hofer M; Korb W; Dietz A; Meixensberger J; Lüth T
    Laryngorhinootologie; 2006 Aug; 85(8):559-66. PubMed ID: 16586288
    [TBL] [Abstract][Full Text] [Related]  

  • 10. IR ear thermometers: what do they measure and how do they comply with the EU technical regulation?
    Pusnik I; van der Ham E; Drnovsek J
    Physiol Meas; 2004 Jun; 25(3):699-708. PubMed ID: 15253121
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a novel calibration technique for optically tracked oblique laparoscopes.
    De Buck S; Maes F; D'Hoore A; Suetens P
    Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):467-74. PubMed ID: 18051092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. National intercomparison program for radiopharmaceutical activity measurements.
    dos Santos JA; Iwahara A; de Oliveira AE; da Silva MA; da Silva CJ; Tauhata L; Lopes RT
    Appl Radiat Isot; 2004; 60(2-4):523-7. PubMed ID: 14987696
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Positioning accuracy in a registration-free CT-based navigation system.
    Brandenberger D; Birkfellner W; Baumann B; Messmer P; Huegli RW; Regazzoni P; Jacob AL
    Phys Med Biol; 2007 Dec; 52(23):7073-86. PubMed ID: 18029994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phantom validation of coregistration of PET and CT for image-guided radiotherapy.
    Lavely WC; Scarfone C; Cevikalp H; Li R; Byrne DW; Cmelak AJ; Dawant B; Price RR; Hallahan DE; Fitzpatrick JM
    Med Phys; 2004 May; 31(5):1083-92. PubMed ID: 15191296
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy assessment of image-guided implant surgery: an experimental study.
    Hoffmann J; Westendorff C; Schneider M; Reinert S
    Int J Oral Maxillofac Implants; 2005; 20(3):382-6. PubMed ID: 15973949
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technical accuracy of an O-arm registered surgical navigator.
    Koivukangas T; Katisko JP; Koivukangas JP
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():2148-51. PubMed ID: 22254763
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy and stability of positioning in radiosurgery: long-term results of the Gamma Knife system.
    Heck B; Jess-Hempen A; Kreiner HJ; Schöpgens H; Mack A
    Med Phys; 2007 Apr; 34(4):1487-95. PubMed ID: 17500479
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Activity measurements with radionuclide calibrators in the Czech Republic.
    Olsovcová V
    Appl Radiat Isot; 2004; 60(2-4):535-8. PubMed ID: 14987698
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display.
    Chen X; Xu L; Wang Y; Wang H; Wang F; Zeng X; Wang Q; Egger J
    J Biomed Inform; 2015 Jun; 55():124-31. PubMed ID: 25882923
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibration and validation by professional observers of the Mission-Quality criterion for imaging systems design.
    Kattnig AP; Primot J
    Opt Express; 2008 Mar; 16(7):4824-37. PubMed ID: 18542581
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.