These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 1613518)

  • 1. Treatment of fractures about hip prostheses with compression plating.
    Serocki JH; Chandler RW; Dorr LD
    J Arthroplasty; 1992 Jun; 7(2):129-35. PubMed ID: 1613518
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nonunion after periprosthetic femoral fracture associated with total hip arthroplasty.
    Crockarell JR; Berry DJ; Lewallen DG
    J Bone Joint Surg Am; 1999 Aug; 81(8):1073-9. PubMed ID: 10466640
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures.
    Bryant GK; Morshed S; Agel J; Henley MB; Barei DP; Taitsman LA; Nork SE
    Injury; 2009 Nov; 40(11):1180-6. PubMed ID: 19539924
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interprosthetic femoral fractures.
    Mamczak CN; Gardner MJ; Bolhofner B; Borrelli J; Streubel PN; Ricci WM
    J Orthop Trauma; 2010 Dec; 24(12):740-4. PubMed ID: 21063218
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Limited open reduction and double plates internal fixation for treatment of Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty].
    Zhang Y; Fan X; Liu Y; Shao J; Tang J; Liu S; Yang T; Zhang C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1428-31. PubMed ID: 24640358
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures.
    Buttaro MA; Farfalli G; Paredes Núñez M; Comba F; Piccaluga F
    J Bone Joint Surg Am; 2007 Sep; 89(9):1964-9. PubMed ID: 17768193
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High union rates of locking compression plating with cortical strut allograft for type B1 periprosthetic femoral fractures.
    Yeo I; Rhyu KH; Kim SM; Park YS; Lim SJ
    Int Orthop; 2016 Nov; 40(11):2365-2371. PubMed ID: 26759257
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Treatment of Vancouver type B1 periprosthetic femoral fracture with locked plate and xenogenic bony plate].
    Chen Q; Chen W; Ding ZQ; Liu GJ; Gao JT; Liu Y
    Zhongguo Gu Shang; 2016 Aug; 29(8):734-737. PubMed ID: 29282933
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical outcome of interprosthetic femoral fractures treated with polyaxial locking plates.
    Hoffmann MF; Lotzien S; Schildhauer TA
    Injury; 2016 Apr; 47(4):934-8. PubMed ID: 26792022
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Locking compression plate versus revision-prosthesis for Vancouver type B2 periprosthetic femoral fractures after total hip arthroplasty.
    Joestl J; Hofbauer M; Lang N; Tiefenboeck T; Hajdu S
    Injury; 2016 Apr; 47(4):939-43. PubMed ID: 26872997
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30-month follow-up.
    Xue H; Tu Y; Cai M; Yang A
    J Arthroplasty; 2011 Apr; 26(3):467-471.e1. PubMed ID: 20570098
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants.
    Wood GC; Naudie DR; McAuley J; McCalden RW
    J Arthroplasty; 2011 Sep; 26(6):886-92. PubMed ID: 20817391
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Femoral fractures following total hip prosthesis].
    Zuber K; Koch P; Lustenberger A; Ganz R
    Unfallchirurg; 1990 Oct; 93(10):467-72. PubMed ID: 2247780
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem.
    Meek RM; Garbuz DS; Masri BA; Greidanus NV; Duncan CP
    J Bone Joint Surg Am; 2004 Mar; 86(3):480-5. PubMed ID: 14996872
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fracture of the shaft of the femur at the apex of the stem of a femoral prosthesis.
    Agrifoglio E
    Ital J Orthop Traumatol; 1983 Jun; 9(2):219-23. PubMed ID: 6654657
    [TBL] [Abstract][Full Text] [Related]  

  • 16. One-stage revision of periprosthetic fractures around loose cemented total hip arthroplasty.
    Incavo SJ; Beard DM; Pupparo F; Ries M; Wiedel J
    Am J Orthop (Belle Mead NJ); 1998 Jan; 27(1):35-41. PubMed ID: 9452834
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Periprosthetic Femoral Fractures after Total Hip Replacement: Our Results and Treatment Complications].
    Pavelka T; Salášek M; Weisová D
    Acta Chir Orthop Traumatol Cech; 2017; 84(1):52-58. PubMed ID: 28253947
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Management of intraoperative femur fractures associated with revision hip arthroplasty.
    Christensen CM; Seger BM; Schultz RB
    Clin Orthop Relat Res; 1989 Nov; (248):177-80. PubMed ID: 2805477
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Management of periprosthetic femur fractures with a first generation locking plate.
    Fulkerson E; Tejwani N; Stuchin S; Egol K
    Injury; 2007 Aug; 38(8):965-72. PubMed ID: 17561020
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamic fixation of distal femur fractures using far cortical locking screws: a prospective observational study.
    Bottlang M; Fitzpatrick DC; Sheerin D; Kubiak E; Gellman R; Vande Zandschulp C; Doornink J; Earley K; Madey SM
    J Orthop Trauma; 2014 Apr; 28(4):181-8. PubMed ID: 24231583
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.