These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 1614752)

  • 1. Correcting for the Bernoulli effect in lateral pressure measurements.
    Bates JH; Sly PD; Sato J; Davey BL; Suki B
    Pediatr Pulmonol; 1992 Apr; 12(4):251-6. PubMed ID: 1614752
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Direct tracheal airway pressure measurements are essential for safe and accurate dynamic monitoring of respiratory mechanics. A laboratory study.
    Kárason S; Søndergaard S; Lundin S; Wiklund J; Stenqvist O
    Acta Anaesthesiol Scand; 2001 Feb; 45(2):173-9. PubMed ID: 11167162
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The unsteady form of the Bernoulli equation for estimating pressure drop in the airways.
    Moslehi F; Ligas JR; Pisani MA; Epstein MA
    Respir Physiol; 1989 Jun; 76(3):319-26. PubMed ID: 2749031
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measuring the mechanical properties of the lung in vivo with spatial resolution at the acinar level.
    Bates JH; Mishima M; Balassy Z
    Physiol Meas; 1995 Aug; 16(3):151-9. PubMed ID: 7488975
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An approach to the study of upper airway function in humans.
    Younes M; Sanii R; Patrick W; Marantz S; Webster K
    J Appl Physiol (1985); 1994 Sep; 77(3):1383-94. PubMed ID: 7836143
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Theory and measurements of snores.
    Gavriely N; Jensen O
    J Appl Physiol (1985); 1993 Jun; 74(6):2828-37. PubMed ID: 8365987
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study.
    Singh R; Courtney SE; Weisner MD; Habib RH
    J Appl Physiol (1985); 2012 Apr; 112(7):1105-13. PubMed ID: 22207721
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Influence of Different Mouthpieces on Impulse Oscillometry Results.
    Dionísio GH; Dos Santos DO; Perossi L; de Paula MH; de Souza HCD; Gastaldi AC
    Respir Care; 2018 May; 63(5):565-572. PubMed ID: 29487095
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Small-amplitude pressure oscillations do not modify respiratory mechanics in rabbits.
    Peslin R; Saunier C; Gallina C; Duvivier C
    J Appl Physiol (1985); 1994 Mar; 76(3):1011-3. PubMed ID: 8005839
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulmonary mechanics during mechanical ventilation.
    Henderson WR; Sheel AW
    Respir Physiol Neurobiol; 2012 Mar; 180(2-3):162-72. PubMed ID: 22154694
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of airflow perturbation device resistance measurements in excised sheep lungs.
    Johnson AT; Sahota MS
    Physiol Meas; 2004 Jun; 25(3):679-90. PubMed ID: 15253119
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Respiratory mechanics in mechanically ventilated newborns: a comparison between passive inflation and occlusion methods.
    Storme L; Riou Y; Leclerc F; Kacet N; Dubos JP; Gremillet C; Rousseau S; Lequien P
    Pediatr Pulmonol; 1992 Apr; 12(4):203-12. PubMed ID: 1614746
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lung constant-pressure inflation: fluid dynamic factors are the basis of airway overpressure during bronchoconstriction.
    Marano G; Doria GP
    Pharmacol Res; 1993; 28(3):185-92. PubMed ID: 8108308
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of resistive load on the phase difference between chest and mouth flow in patients with chronic obstructive pulmonary disease.
    Mishima M; Higashiya K; Kawakami K; Sugiura N; Sakai N; Hirai T; Oku Y; Chin K; Ohi M; Kuno K
    Front Med Biol Eng; 1997; 8(1):1-18. PubMed ID: 9083797
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Airway stability and heterogeneity in the constricted lung.
    Anafi RC; Wilson TA
    J Appl Physiol (1985); 2001 Sep; 91(3):1185-92. PubMed ID: 11509514
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The information value of the method of forced oscillations in research on respiratory mechanics].
    Baranov VM; D'iachenko AI
    Usp Fiziol Nauk; 1991; 22(3):25-40. PubMed ID: 1950088
    [No Abstract]   [Full Text] [Related]  

  • 17. Variation of respiratory resistance suggests optimization of airway caliber.
    Johnson AT; Jones SC; Pan JJ; Vossoughi J
    IEEE Trans Biomed Eng; 2012 Aug; 59(8):2355-61. PubMed ID: 22711765
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Oscillatory pressure transients after flow interruption during bronchial challenge test in children.
    Frey U; Kraemer R
    Eur Respir J; 1997 Jan; 10(1):75-81. PubMed ID: 9032496
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Total respiratory input impedance with the upper airway wall shunt minimized.
    Habib RH; Jackson AC
    J Appl Physiol (1985); 1993 Mar; 74(3):1045-55. PubMed ID: 8482641
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new ventilator for monitoring lung mechanics in small animals.
    Volgyesi GA; Tremblay LN; Webster P; Zamel N; Slutsky AS
    J Appl Physiol (1985); 2000 Aug; 89(2):413-21. PubMed ID: 10926621
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.