These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

72 related articles for article (PubMed ID: 1615068)

  • 1. Improved salvage of complicated microvascular transplants monitored with quantitative fluorometry.
    Whitney TM; Lineaweaver WC; Billys JB; Siko PP; Buncke GM; Alpert BS; Oliva A; Buncke HJ
    Plast Reconstr Surg; 1992 Jul; 90(1):105-11. PubMed ID: 1615068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Muscle flap monitoring in a rat model with a variable gain quantitative fluorometer.
    Yim KK; Lineaweaver WC; Silverman DG; Konkin B; Newlin L; Buncke HJ
    Ann Plast Surg; 1992 Jun; 28(6):511-5. PubMed ID: 1622031
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Establishment of normal ranges of laser Doppler blood flow in autologous tissue transplants.
    Clinton MS; Sepka RS; Bristol D; Pederson WC; Barwick WJ; Serafin D; Klitzman B
    Plast Reconstr Surg; 1991 Feb; 87(2):299-309. PubMed ID: 1824878
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Routine use of laser Doppler flowmetry for monitoring autologous tissue transplants.
    Jenkins S; Sepka R; Barwick WJ
    Ann Plast Surg; 1988 Nov; 21(5):423-6. PubMed ID: 3069034
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative fluorometry as a monitor for microvascular surgery.
    Copeland J; Harman RD; Wells HG; Puckett CL
    J Hand Surg Am; 1987 Mar; 12(2):250-5. PubMed ID: 3559080
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variations in flap blood flow and tissue PO2: a new technique for monitoring flap viability.
    Mahoney JL; Lista FR
    Ann Plast Surg; 1988 Jan; 20(1):43-7. PubMed ID: 3341715
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Vascular complications of vascularized composite tissue transfer: outcome and salvage techniques.
    Yajima H; Tamai S; Mizumoto S; Ono H; Fukui A
    Microsurgery; 1993; 14(8):473-8. PubMed ID: 8271924
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical and experimental studies of cigarette smoking in microvascular tissue transfers.
    Gu YD; Zhang GM; Zhang LY; Li FG; Jiang JF
    Microsurgery; 1993; 14(6):391-7. PubMed ID: 8371687
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Role of monitoring in microvascular or vascular pedicled tissue transfer].
    Wahlmann UW; Wagner W
    Fortschr Kiefer Gesichtschir; 1990; 35():34-6. PubMed ID: 2197197
    [No Abstract]   [Full Text] [Related]  

  • 10. Prognostication of myocutaneous flap viability using laser Doppler velocimetry and fluorescein microfluorometry.
    Cummings CW; Trachy RE; Richardson MA; Patterson HC
    Otolaryngol Head Neck Surg; 1984 Oct; 92(5):559-63. PubMed ID: 6239129
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Venous outflow obstruction in myocutaneous flaps: changes in microcirculation detected by the perfusion fluorometer and laser Doppler.
    Liu AJ; Cummings CW; Trachy RE
    Otolaryngol Head Neck Surg; 1986 Feb; 94(2):164-8. PubMed ID: 2938054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique.
    Hidalgo DA; Disa JJ; Cordeiro PG; Hu QY
    Plast Reconstr Surg; 1998 Sep; 102(3):722-32; discussion 733-4. PubMed ID: 9727437
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monitoring tissue elimination of fluorescein with the perfusion fluorometer: a new method to assess capillary blood flow.
    Silverman DG; Cedrone FA; Hurford WE; Bering TG; LaRossa DD
    Surgery; 1981 Aug; 90(2):409-17. PubMed ID: 7256549
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Techniques of postoperative blood flow monitoring after free tissue transfer: an overview.
    Machens HG; Mailaender P; Rieck B; Berger A
    Microsurgery; 1994; 15(11):778-86. PubMed ID: 7700139
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monitoring free flap perfusion by serial fluorometry.
    Denneny JC; Weisman RA; Silverman DG
    Otolaryngol Head Neck Surg; 1983 Aug; 91(4):372-6. PubMed ID: 6415582
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of flap viability with a dermal surface fluorometer.
    Casanova R; Iribarren O; Grotting JC; Vasconez LO
    Ann Plast Surg; 1988 Feb; 20(2):112-6. PubMed ID: 3355054
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases.
    Disa JJ; Cordeiro PG; Hidalgo DA
    Plast Reconstr Surg; 1999 Jul; 104(1):97-101. PubMed ID: 10597680
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Angiodynography: a noninvasive procedure for planning and follow-up of microsurgical anastomosis of transplants].
    Reinert S; Fritzemeier CU; Kuhn FP
    Fortschr Kiefer Gesichtschir; 1990; 35():36-8. PubMed ID: 2197198
    [No Abstract]   [Full Text] [Related]  

  • 19. Fiberoptic fluorometer for skin flap assessment.
    Weisman RA; Silverman DG
    Otolaryngol Head Neck Surg; 1983 Aug; 91(4):377-9. PubMed ID: 6415583
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Techniques for postoperative monitoring of tissue circulation after free microvascular tissue transplantation].
    Machens HG; Mailänder P; Kremer M; Reimer R; Berger A
    Handchir Mikrochir Plast Chir; 1999 Mar; 31(2):107-12. PubMed ID: 10337555
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.