These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

294 related articles for article (PubMed ID: 16153000)

  • 41. [Effect of gender and body mass on hemodialysis dose].
    Kovacić V; Sain M; Dzanko D
    Acta Med Croatica; 2003; 57(1):33-7. PubMed ID: 12876860
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Ionic dialysance: principle and review of its clinical relevance for quantification of hemodialysis efficiency.
    Mercadal L; Ridel C; Petitclerc T
    Hemodial Int; 2005 Apr; 9(2):111-9. PubMed ID: 16191058
    [TBL] [Abstract][Full Text] [Related]  

  • 43. What volume to choose to assess online Kt/V?
    Casino FG; Mancini E; Santarsia G; Mostacci SD; D'Elia F; Di Carlo M; Iannuzzella F; Rossi L; Vernaglione L; Grimaldi D; Rapanà R; Basile C
    J Nephrol; 2020 Feb; 33(1):137-146. PubMed ID: 31392658
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Characterization of treatment dose delivered by albumin dialysis in the treatment of acute renal failure associated with severe hepatic dysfunction.
    McIntyre CW; Fluck RJ; Freeman JG; Lambie SH
    Clin Nephrol; 2002 Nov; 58(5):376-83. PubMed ID: 12425489
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The urea [clearance x dialysis time] product (Kt) as an outcome-based measure of hemodialysis dose.
    Lowrie EG; Chertow GM; Lew NL; Lazarus JM; Owen WF
    Kidney Int; 1999 Aug; 56(2):729-37. PubMed ID: 10432415
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Kt as control and follow-up of the dose at a hemodialysis unit].
    Maduell F; Vera M; Serra N; Collado S; Carrera M; Fernández A; Arias M; Blasco M; Burgadá E; Cases A; Campistol JM
    Nefrologia; 2008; 28(1):43-7. PubMed ID: 18336130
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Estimating dialysis adequacy using ionic dialysance.
    Carl DE; Feldman G
    Ren Fail; 2008; 30(5):491-8. PubMed ID: 18569928
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Determination of urea distribution volume for Kt/V assessed by conductivity monitoring.
    Wuepper A; Tattersall J; Kraemer M; Wilkie M; Edwards L
    Kidney Int; 2003 Dec; 64(6):2262-71. PubMed ID: 14633151
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Comparison of single-pool and equilibrated Kt/V values for pediatric hemodialysis prescription management: analysis from the Centers for Medicare & Medicaid Services Clinical Performance Measures Project.
    Goldstein SL; Brem A; Warady BA; Fivush B; Frankenfield D
    Pediatr Nephrol; 2006 Aug; 21(8):1161-6. PubMed ID: 16705459
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Improving the efficiency of short-term single-needle hemodialysis.
    Rostoker G; Griuncelli M; Loridon C; Bourlet T; Welsch K; Benmaadi A
    Ren Fail; 2009; 31(4):261-6. PubMed ID: 19462273
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Chronic renal replacement therapy in children: which index is best for adequacy?
    Verrina E; Brendolan A; Gusmano R; Ronco C
    Kidney Int; 1998 Nov; 54(5):1690-6. PubMed ID: 9844146
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Comparisons of Kt/V evaluated using an online method and calculated from urea measurements in patients on intermittent hemodialysis.
    Grzegorzewska AE; Banachowicz W
    Hemodial Int; 2006 Oct; 10 Suppl 2():S5-9. PubMed ID: 17022752
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Effects of postdialysis urea rebound on the quantification of pediatric hemodialysis.
    Marsenić O; Pavlicić D; Bigović G; Peco-Antić A; Jovanović O
    Nephron; 2000 Feb; 84(2):124-9. PubMed ID: 10657712
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Urea distribution volume calculated by ionic dialysance].
    Teruel JL; Merino JL; Fernández-Lucas M; Tenorio MT; Rivera M; Marcén R; Ortuño J
    Nefrologia; 2006; 26(1):121-7. PubMed ID: 16649433
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Imprecision of the hemodialysis dose when measured directly from urea removal. Hemodialysis Study Group.
    Depner TA; Greene T; Gotch FA; Daugirdas JT; Keshaviah PR; Star RA
    Kidney Int; 1999 Feb; 55(2):635-47. PubMed ID: 9987088
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Prediction of equilibrated urea in children on chronic hemodialysis.
    Marsenić OD; Pavlicić D; Peco-Antić A; Bigović G; Jovanović O
    ASAIO J; 2000; 46(3):283-7. PubMed ID: 10826737
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparison of methods to predict equilibrated Kt/V in the HEMO Pilot Study.
    Daugirdas JT; Depner TA; Gotch FA; Greene T; Keshaviah P; Levin NW; Schulman G
    Kidney Int; 1997 Nov; 52(5):1395-405. PubMed ID: 9350665
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Ionic dialysance and quality control in hemodialysis].
    Petitclerc T; Coevoet B
    Nephrologie; 2001; 22(5):191-7. PubMed ID: 11572165
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [Ionic dialysance: which relationship with effective urea clearance?].
    Pozzoni P; Pozzi M; Di Filippo S
    G Ital Nefrol; 2004; 21 Suppl 30():S231-5. PubMed ID: 15750994
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Relationship between effective ionic dialysance and in vivo urea clearance during hemodialysis.
    Lindsay RM; Bene B; Goux N; Heidenheim AP; Landgren C; Sternby J
    Am J Kidney Dis; 2001 Sep; 38(3):565-74. PubMed ID: 11532690
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.