These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 16156307)

  • 1. Hemodynamic and gas transfer properties of a compliant thoracic artificial lung.
    Cook KE; Perlman CE; Seipelt R; Backer CL; Mavroudis C; Mockrost LF
    ASAIO J; 2005; 51(4):404-11. PubMed ID: 16156307
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and evaluation of a new, low pressure loss, implantable artificial lung.
    Vaslef SN; Cook KE; Leonard RJ; Mockros LF; Anderson RW
    ASAIO J; 1994; 40(3):M522-6. PubMed ID: 8555571
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Testing of an intrathoracic artificial lung in a pig model.
    Cook KE; Makarewicz AJ; Backer CL; Mockros LF; Przybylo HJ; Crawford SE; Hernandez JM; Leonard RJ; Mavroudis C
    ASAIO J; 1996; 42(5):M604-9. PubMed ID: 8944952
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo hemodynamic responses to thoracic artificial lung attachment.
    Perlman CE; Cook KE; Seipelt JR; Mavroudis JC; Backer JC; Mockros LF
    ASAIO J; 2005; 51(4):412-25. PubMed ID: 16156308
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and in vitro assessment of an improved, low-resistance compliant thoracic artificial lung.
    Schewe RE; Khanafer KM; Arab A; Mitchell JA; Skoog DJ; Cook KE
    ASAIO J; 2012; 58(6):583-9. PubMed ID: 23103694
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of artificial lung compliance on in vivo pulmonary system hemodynamics.
    Sato H; McGillicuddy JW; Griffith GW; Cosnowski AM; Chambers SD; Hirschl RB; Bartlett RH; Cook KE
    ASAIO J; 2006; 52(3):248-56. PubMed ID: 16760712
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemodynamic effects of attachment modes and device design of a thoracic artificial lung.
    Boschetti F; Perlman CE; Cook KE; Mockros LF
    ASAIO J; 2000; 46(1):42-8. PubMed ID: 10667715
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A pumping artificial lung.
    Makarewicz AJ; Mockros LF; Anderson RW
    ASAIO J; 1994; 40(3):M518-21. PubMed ID: 8555570
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thirty-day in-parallel artificial lung testing in sheep.
    Sato H; Hall CM; Lafayette NG; Pohlmann JR; Padiyar N; Toomasian JM; Haft JW; Cook KE
    Ann Thorac Surg; 2007 Oct; 84(4):1136-43; discussion 1143. PubMed ID: 17888959
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thoracic artificial lung impedance studies using computational fluid dynamics and in vitro models.
    Schewe RE; Khanafer KM; Orizondo RA; Cook KE
    Ann Biomed Eng; 2012 Mar; 40(3):628-36. PubMed ID: 22009316
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hemodynamic design requirements for in-series thoracic artificial lung attachment in a model of pulmonary hypertension.
    Akay B; Foucher JA; Camboni D; Koch KL; Kawatra A; Cook KE
    ASAIO J; 2012; 58(4):426-31. PubMed ID: 22581034
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New design for a pumping artificial lung.
    Makarewicz AJ; Mockros LF; Mavroudis C
    ASAIO J; 1996; 42(5):M615-9. PubMed ID: 8944954
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of blood phase oscillation on gas transfer in a microporous intravascular lung.
    High KM; Nicholson T; Richard RB; Panol GR; Shelley K; Snider MT
    ASAIO J; 1994; 40(3):M735-9. PubMed ID: 8555612
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A dynamic intravascular artificial lung.
    Makarewicz AJ; Mockros LF; Anderson RW
    ASAIO J; 1994; 40(3):M747-50. PubMed ID: 8555615
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulation.
    Lick SD; Zwischenberger JB; Wang D; Deyo DJ; Alpard SK; Chambers SD
    Ann Thorac Surg; 2001 Sep; 72(3):899-904. PubMed ID: 11570380
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Blood flow pulsatility effects upon oxygen transfer in artificial lungs.
    Boschetti F; Cook KE; Perlman CE; Mockros LF
    ASAIO J; 2003; 49(6):678-86. PubMed ID: 14655734
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The development of an implantable artificial lung.
    Fazzalari FL; Montoya JP; Bonnell MR; Bliss DW; Hirschl RB; Bartlett RH
    ASAIO J; 1994; 40(3):M728-31. PubMed ID: 8555610
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro fluid mechanical effects of thoracic artificial lung compliance.
    McGillicuddy JW; Chambers SD; Galligan DT; Hirschl RB; Bartlett RH; Cook KE
    ASAIO J; 2005; 51(6):789-94. PubMed ID: 16340369
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental safety and efficacy evaluation of an extracorporeal pumpless artificial lung in providing respiratory support through the axillary vessels.
    Iglesias M; Jungebluth P; Sibila O; Aldabo I; Matute MP; Petit C; Torres A; Macchiarini P
    J Thorac Cardiovasc Surg; 2007 Feb; 133(2):339-45. PubMed ID: 17258560
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Small intrapulmonary artery lung prototypes: design, construction, and in vitro water testing.
    Snider MT; High KM; Richard RB; Panol G; Campbell EA; Service CV; Stene JK; Ultman JS
    ASAIO J; 1994; 40(3):M533-9. PubMed ID: 8555573
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.