108 related articles for article (PubMed ID: 1615859)
1. Echocardiographic frequency and severity of aortic regurgitation after ultrasonic aortic valve debridement for aortic stenosis in persons aged greater than 65 years.
McKenney PA; Balady GJ; Ryan TJ; Shemin RJ
Am J Cardiol; 1992 Jul; 70(1):125-7. PubMed ID: 1615859
[No Abstract] [Full Text] [Related]
2. Ultrasonic aortic valve decalcification: serial Doppler echocardiographic follow-up.
Freeman WK; Schaff HV; Orszulak TA; Tajik AJ
J Am Coll Cardiol; 1990 Sep; 16(3):623-30. PubMed ID: 2387935
[TBL] [Abstract][Full Text] [Related]
3. Ultrasonic debridement of the aortic valve with six-month echocardiographic follow-up.
Scott WJ; Neumann AL; Karp RB
Am J Cardiol; 1989 Nov; 64(18):1206-9. PubMed ID: 2816775
[No Abstract] [Full Text] [Related]
4. Combined conventional mechanical and ultrasonic debridement for aortic valvular stenosis.
Baeza OR; Majid NK; Conroy DP; Donahoo JS
Ann Thorac Surg; 1992 Jul; 54(1):62-7. PubMed ID: 1610256
[TBL] [Abstract][Full Text] [Related]
5. Aortic valve debridement by ultrasonic surgical aspirator: a word of caution.
Craver JM
Ann Thorac Surg; 1990 May; 49(5):746-52; discussion 752-3. PubMed ID: 2339931
[TBL] [Abstract][Full Text] [Related]
6. [Ultrasonic decalcification in aortic stenosis. Clinical and doppler echocardiographic results].
Tarelli G; Verna E; Respighi E; Santarone M; Luvini M; Repetto S
G Ital Cardiol; 1992 Feb; 22(2):155-61. PubMed ID: 1628778
[TBL] [Abstract][Full Text] [Related]
7. Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: impact of aortic cusp calcification on postoperative aortic regurgitation.
Colli A; D'Amico R; Kempfert J; Borger MA; Mohr FW; Walther T
J Thorac Cardiovasc Surg; 2011 Nov; 142(5):1229-35. PubMed ID: 22014345
[TBL] [Abstract][Full Text] [Related]
8. "Conservative" aortic valve intervention: thwarted again!
Campbell DB; Waldhausen JA
J Am Coll Cardiol; 1990 Sep; 16(3):631-2. PubMed ID: 2387936
[No Abstract] [Full Text] [Related]
9. Quantification of paravalvular regurgitation after transcatheter aortic valve implantation: improved accuracy means better standardization.
Lancellotti P; Piazza N; Modine T
Eur Heart J Cardiovasc Imaging; 2016 Aug; 17(8):861-2. PubMed ID: 27252487
[No Abstract] [Full Text] [Related]
10. Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation.
Gripari P; Ewe SH; Fusini L; Muratori M; Ng AC; Cefalù C; Delgado V; Schalij MJ; Bax JJ; Marsan NA; Tamborini G; Pepi M
Heart; 2012 Aug; 98(16):1229-36. PubMed ID: 22826560
[TBL] [Abstract][Full Text] [Related]
11. Regression of Paravalvular Aortic Regurgitation and Remodeling of Self-Expanding Transcatheter Aortic Valve: An Observation From the CoreValve U.S. Pivotal Trial.
Oh JK; Little SH; Abdelmoneim SS; Reardon MJ; Kleiman NS; Lin G; Bach D; Gillam L; Kar B; Coselli J; Sengupta PP; Grewal K; Chang J; Chang Y; Boulware M; Adams DH; Popma JJ;
JACC Cardiovasc Imaging; 2015 Dec; 8(12):1364-1375. PubMed ID: 26508386
[TBL] [Abstract][Full Text] [Related]
12. Assessment of Post-Procedural Aortic Regurgitation After TAVR: An Intraprocedural TEE Study.
Mihara H; Shibayama K; Jilaihawi H; Itabashi Y; Berdejo J; Utsunomiya H; Siegel RJ; Makkar RR; Shiota T
JACC Cardiovasc Imaging; 2015 Sep; 8(9):993-1003. PubMed ID: 26319501
[TBL] [Abstract][Full Text] [Related]
13. Impact of device landing zone calcification on paravalvular regurgitation after transcatheter aortic valve replacement: a real-time three-dimensional transesophageal echocardiographic study.
Mihara H; Shibayama K; Berdejo J; Harada K; Itabashi Y; Siegel RJ; Kashif M; Jilaihawi H; Makkar RR; Shiota T
J Am Soc Echocardiogr; 2015 Apr; 28(4):404-14. PubMed ID: 25560483
[TBL] [Abstract][Full Text] [Related]
14. Aortic valve debridement by ultrasonic surgical aspirator in degenerative, aortic valve stenosis: follow-up with Doppler echocardiography.
Kellner HJ; Pracki P; Hildebrandt A; Binner C; Eisele G; Struck E
Eur J Cardiothorac Surg; 1996; 10(7):498-504. PubMed ID: 8855420
[TBL] [Abstract][Full Text] [Related]
15. Aortic valve decalcification: history repeated with a new result.
Cosgrove DM; Ratliff NB; Schaff HV; Edwards WD
Ann Thorac Surg; 1990 May; 49(5):689-90. PubMed ID: 2339924
[No Abstract] [Full Text] [Related]
16. [Ultrasonic decalcification of the aortic valve. Initial experience].
Gallo I; Sáenz A; Alonso C; Germán A; Cesari F; Alberdi I; Doxandabaratz J; Larmán M; Martínez de Ubago JL
Rev Esp Cardiol; 1992; 45(7):486-8. PubMed ID: 1439075
[TBL] [Abstract][Full Text] [Related]
17. Immediate, same-setting paravalvular leak closure following transcatheter aortic valve replacement.
White JM; Khalique OK; Kodali SK
Int J Cardiol; 2015; 189():235-7. PubMed ID: 25897915
[No Abstract] [Full Text] [Related]
18. Abrasion-debridement of aortic valve calcific stenosis. Immediate and mid-term clinical results.
Mezzacapo B
J Cardiovasc Surg (Torino); 1998 Oct; 39(5):667-72. PubMed ID: 9833731
[TBL] [Abstract][Full Text] [Related]
19. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
[TBL] [Abstract][Full Text] [Related]
20. Aortic regurgitation after transcatheter aortic valve implantation (TAVI) - Angiographic, echocardiographic and hemodynamic assessment in relation to one year outcome.
Collas VM; Paelinck BP; Rodrigus IE; Vrints CJ; Bosmans JM
Int J Cardiol; 2015 Sep; 194():13-20. PubMed ID: 26011259
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]