These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 1616589)

  • 41. Quantitative evaluation of dosimetric uncertainties associated with small electron fields.
    Ali I; Kendall E; Alsbou N; Ahmad S
    J Med Imaging Radiat Sci; 2022 Jun; 53(2):273-282. PubMed ID: 35304080
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.
    Bucciolini M; Buonamici FB; Mazzocchi S; De Angelis C; Onori S; Cirrone GA
    Med Phys; 2003 Aug; 30(8):2149-54. PubMed ID: 12945980
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Calculation of electron beam depth-dose curves and output factors for arbitrary field shapes.
    Bruinvis IA; Mathol WA
    Radiother Oncol; 1988 Apr; 11(4):395-404. PubMed ID: 3131845
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A 2D silicon detector array for quality assurance in small field dosimetry: DUO.
    Shukaili KA; Petasecca M; Newall M; Espinoza A; Perevertaylo VL; Corde S; Lerch M; Rosenfeld AB
    Med Phys; 2017 Feb; 44(2):628-636. PubMed ID: 28152195
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac-18 accelerator.
    McCullough EC; Anderson JA
    Med Phys; 1982; 9(2):261-8. PubMed ID: 6806596
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A diamond detector in the dosimetry of high-energy electron and photon beams.
    Laub WU; Kaulich TW; Nüsslin F
    Phys Med Biol; 1999 Sep; 44(9):2183-92. PubMed ID: 10495113
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Comparison of the Characteristics of Two Types of Parallel-plate Ionization Chamber Under Small-field Electron Irradiation.
    Yanagi Y; Monzen H; Kubo K; Sugiyama J; Noma K; Ito T; Sakai Y; Nakamura K; Kida T; Doi H; Nishimura Y
    Anticancer Res; 2023 May; 43(5):1967-1972. PubMed ID: 37097686
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Dosimetry of small electron fields shaped by lead.
    Perez MD; Hill RF; Whitaker MK; Greig L; West MP; Williams MJ; Holloway LC
    Australas Phys Eng Sci Med; 2003 Sep; 26(3):119-24. PubMed ID: 14626851
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Dosimetric characterization of the 18-MV photon beam from the Siemens Mevatron 77 linear accelerator.
    Palta JR; Meyer JA; Hogstrom KR
    Med Phys; 1984; 11(5):717-24. PubMed ID: 6438461
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Calibration of high-energy photon and electron beams for radiotherapy using AAPM 1983 and IAEA 1987 dosimetry protocols.
    Huq MS; Agostinelli AG; Nath R
    Med Phys; 1993; 20(2 Pt 1):293-8. PubMed ID: 8497213
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Development of a silicon diode detector for skin dosimetry in radiotherapy.
    Vicoroski N; Espinoza A; Duncan M; Oborn BM; Carolan M; Metcalfe P; Menichelli D; Perevertaylo VL; Lerch MLF; Rosenfeld AB; Petasecca M
    Med Phys; 2017 Oct; 44(10):5402-5412. PubMed ID: 28696500
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Radiotherapy electron beams collimated by small tubular applicators: characterization by silicon and diamond diodes.
    Bagalà P; Di Venanzio C; Falco MD; Guerra AS; Marinelli M; Milani E; Pimpinella M; Pompili F; Prestopino G; Santoni R; Tonnetti A; Verona C; Verona-Rinati G
    Phys Med Biol; 2013 Nov; 58(22):8121-33. PubMed ID: 24200743
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles.
    Zhang Y; Hsi WC; Chu JC; Bernard DB; Abrams RA
    J Appl Clin Med Phys; 2005; 6(2):50-61. PubMed ID: 15940212
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.
    Chetty IJ; Charland PM
    Phys Med Biol; 2002 Oct; 47(20):3629-41. PubMed ID: 12433124
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Electron beam effective source surface distances for a high energy linear accelerator.
    Sharma SC; Johnson MW
    Med Dosim; 1991 Jun; 16(2):65-70. PubMed ID: 1907830
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Quantitative assessment of beam perturbations caused by silicon diodes used for in vivo dosimetry.
    Sen A; Parsai EI; McNeeley SW; Ayyangar KM
    Int J Radiat Oncol Biol Phys; 1996 Aug; 36(1):205-11. PubMed ID: 8823277
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Dosimetry of therapeutic photon beams using an extended dose range film.
    Esthappan J; Mutic S; Harms WB; Dempsey JF; Low DA
    Med Phys; 2002 Oct; 29(10):2438-45. PubMed ID: 12408321
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Fluence correction factors in plastic phantoms for clinical proton beams.
    Palmans H; Symons JE; Denis JM; de Kock EA; Jones DT; Vynckier S
    Phys Med Biol; 2002 Sep; 47(17):3055-71. PubMed ID: 12361210
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Evaluation of the dosimetric properties of a synthetic single crystal diamond detector in high energy clinical proton beams.
    Mandapaka AK; Ghebremedhin A; Patyal B; Marinelli M; Prestopino G; Verona C; Verona-Rinati G
    Med Phys; 2013 Dec; 40(12):121702. PubMed ID: 24320488
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Dose properties of a laser accelerated electron beam and prospects for clinical application.
    Kainz KK; Hogstrom KR; Antolak JA; Almond PR; Bloch CD; Chiu C; Fomytskyi M; Raischel F; Downer M; Tajima T
    Med Phys; 2004 Jul; 31(7):2053-67. PubMed ID: 15305458
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.