809 related articles for article (PubMed ID: 16171662)
21. Regional cerebral saturation versus transcranial Doppler during carotid endarterectomy under regional anaesthesia.
Pugliese F; Ruberto F; Tosi A; Martelli S; Bruno K; Summonti D; D'Alio A; Diana B; Anile M; Panico A; Speziale F; Pietropaoli P
Eur J Anaesthesiol; 2009 Aug; 26(8):643-7. PubMed ID: 19494780
[TBL] [Abstract][Full Text] [Related]
22. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.
Moritz S; Kasprzak P; Arlt M; Taeger K; Metz C
Anesthesiology; 2007 Oct; 107(4):563-9. PubMed ID: 17893451
[TBL] [Abstract][Full Text] [Related]
23. Comparison of cerebral oximeter and evoked potential monitoring in carotid endarterectomy.
Duffy CM; Manninen PH; Chan A; Kearns CF
Can J Anaesth; 1997 Oct; 44(10):1077-81. PubMed ID: 9350367
[TBL] [Abstract][Full Text] [Related]
24. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review.
Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ
Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397
[TBL] [Abstract][Full Text] [Related]
25. [Behaviour of near-infrared cerebral oximetry readings during percutaneous carotid angioplasty].
Rodríguez L; Salvador L; Valero R; Carrero E; Fontanals J; Fàbregas N
Rev Esp Anestesiol Reanim; 2006 Dec; 53(10):633-8. PubMed ID: 17302077
[TBL] [Abstract][Full Text] [Related]
26. Invos Cerebral Oximeter compared with the transcranial Doppler for monitoring adequacy of cerebral perfusion in patients undergoing carotid endarterectomy.
Fassiadis N; Zayed H; Rashid H; Green DW
Int Angiol; 2006 Dec; 25(4):401-6. PubMed ID: 17164748
[TBL] [Abstract][Full Text] [Related]
27. [Near Infrared Spectroscopy for cerebral monitoring during cardiovascular surgery].
La Monaca M; David A; Gaeta R; Lentini S
Clin Ter; 2010; 161(6):549-53. PubMed ID: 21181086
[TBL] [Abstract][Full Text] [Related]
28. Near Infrared Spectroscopy as a Predictor for Shunt Requirement During Carotid Endarterectomy.
Jonsson M; Lindström D; Wanhainen A; Djavani Gidlund K; Gillgren P
Eur J Vasc Endovasc Surg; 2017 Jun; 53(6):783-791. PubMed ID: 28431821
[TBL] [Abstract][Full Text] [Related]
29. Near-infrared spectroscopy in carotid artery stenting predicts cerebral hyperperfusion syndrome.
Matsumoto S; Nakahara I; Higashi T; Iwamuro Y; Watanabe Y; Takahashi K; Ando M; Takezawa M; Kira JI
Neurology; 2009 Apr; 72(17):1512-8. PubMed ID: 19398706
[TBL] [Abstract][Full Text] [Related]
30. Cerebral oximetry in patients undergoing carotid endarterectomy: preliminary results.
Vets P; ten Broecke P; Adriaensen H; Van Schil P; De Hert S
Acta Anaesthesiol Belg; 2004; 55(3):215-20. PubMed ID: 15515298
[TBL] [Abstract][Full Text] [Related]
31. Brain Oxygen Supply Parameters in the Risk Assessment of Cerebral Complications During Carotid Endarterectomy.
Kamenskaya OV; Loginova IY; Lomivorotov VV
J Cardiothorac Vasc Anesth; 2017 Jun; 31(3):944-949. PubMed ID: 28082030
[TBL] [Abstract][Full Text] [Related]
32. [Cerebral ischemia during carotid clamping: diagnosis and prevention].
Lang W; Dinkel M
Zentralbl Chir; 2000; 125(3):243-50. PubMed ID: 10769444
[TBL] [Abstract][Full Text] [Related]
33. Good correlation between cerebral oxygenation measured using near infrared spectroscopy and stump pressure during carotid clamping.
Yamamoto K; Miyata T; Nagawa H
Int Angiol; 2007 Sep; 26(3):262-5. PubMed ID: 17622209
[TBL] [Abstract][Full Text] [Related]
34. [Malfunctioning of cerebral function monitors in three cases of carotid endarterectomy].
Kadoi Y; Kawahara F; Fujita N
Masui; 2000 Jan; 49(1):40-4. PubMed ID: 10689842
[TBL] [Abstract][Full Text] [Related]
35. Non-Invasive Cerebral Autoregulation Monitoring During Awake Carotid Endarterectomy Identifies Clinically Significant Brain Ischaemia.
Zipfel J; Bantle SJ; Magunia H; Schlensak C; Neunhoeffer F; Schuhmann MU; Lescan M
Eur J Vasc Endovasc Surg; 2020 Nov; 60(5):647-654. PubMed ID: 32819817
[TBL] [Abstract][Full Text] [Related]
36. Cerebral oximetry and stump pressure as indicators for shunting during carotid endarterectomy: comparative evaluation.
Tambakis CL; Papadopoulos G; Sergentanis TN; Lagos N; Arnaoutoglou E; Labropoulos N; Matsagkas MI
Vascular; 2011 Aug; 19(4):187-94. PubMed ID: 21764845
[TBL] [Abstract][Full Text] [Related]
37. The influence of inspired oxygen fraction and end-tidal carbon dioxide on post-cross-clamp cerebral oxygenation during carotid endarterectomy under general anesthesia.
Picton P; Chambers J; Shanks A; Dorje P
Anesth Analg; 2010 Feb; 110(2):581-7. PubMed ID: 19955500
[TBL] [Abstract][Full Text] [Related]
38. Correlation of cerebral oximetry with internal carotid artery stump pressures in carotid endarterectomy.
Manwaring ML; Durham CA; McNally MM; Agle SC; Parker FM; Stoner MC
Vasc Endovascular Surg; 2010 May; 44(4):252-6. PubMed ID: 20356866
[TBL] [Abstract][Full Text] [Related]
39. Detection of ischemic electroencephalography changes during carotid endarterectomy using synchronization likelihood analysis.
Rijsdijk M; Ferrier C; Laman M; Kesecioglu J; Stam K; Slooter A
J Neurosurg Anesthesiol; 2009 Oct; 21(4):302-6. PubMed ID: 19955892
[TBL] [Abstract][Full Text] [Related]
40. Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy.
Cho H; Nemoto EM; Yonas H; Balzer J; Sclabassi RJ
J Neurosurg; 1998 Oct; 89(4):533-8. PubMed ID: 9761045
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]