These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 16177679)

  • 1. Dislocation of an atrial pacemaker lead causing repeating self limited ventricular tachycardia and episodes of syncope.
    Schachner T; Cottogni M; Laufer G; Friedrich G
    Minerva Cardioangiol; 2005 Aug; 53(4):336-7. PubMed ID: 16177679
    [No Abstract]   [Full Text] [Related]  

  • 2. Initiation of ventricular tachycardia by interruption of pacemaker-mediated tachycardia in a patient with a dual-chamber implantable cardioverter defibrillator.
    Van Gelder BM; Meijer A; Dekker LR; Bracke FA
    Pacing Clin Electrophysiol; 2009 Sep; 32(9):1227-30. PubMed ID: 19719503
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Epicardial pacemaker lead-induced ventricular tachycardia.
    Kwak JG; Kim WH; Bae EJ
    Ann Thorac Surg; 2009 Mar; 87(3):942-3. PubMed ID: 19231430
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Repetitive non-reentrant VA synchrony and pacemaker-mediated tachycardia induced by the AF suppression algorithm.
    Kohno R; Abe H; Nagatomo T; Otsuji Y
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1333-5. PubMed ID: 19732366
    [No Abstract]   [Full Text] [Related]  

  • 5. Pseudomalfunction of a dual chamber pacemaker caused by accelerated junctional rhythm and alternating ventricular safety pacing.
    Cheng ST; Yeh KH
    Europace; 2008 May; 10(5):591-2. PubMed ID: 18227353
    [No Abstract]   [Full Text] [Related]  

  • 6. [Clinical case of the month. Rapid atrial fibrillation causing ventricular tachycardia and syncope].
    Guillaume T; Mélon P; Bouffioux L; Antonakis V; Krzesinski JM
    Rev Med Liege; 2003; 58(7-8):468-71. PubMed ID: 14579609
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Syncope following cardioverter defibrillator implantation in patients with spontaneous syncopal monomorphic ventricular tachycardia.
    Abello M; Merino JL; Peinado R; Gnoatto M; Arias MA; Gonzalez-Vasserot M; Sobrino JA
    Eur Heart J; 2006 Jan; 27(1):89-95. PubMed ID: 16183691
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Postural syncope as a manifestation of fractured pacemaker lead.
    Singhal SS; Dyal A; Agarwal DK
    Indian Heart J; 1986; 38(5):423-4. PubMed ID: 3570333
    [No Abstract]   [Full Text] [Related]  

  • 9. Pacemaker tachycardia in a minute ventilation rate-adaptive pacemaker induced by electrocardiographic monitoring.
    Lau W; Corcoran SJ; Mond HG
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):438-40. PubMed ID: 16650278
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid ventricular pacing due to electrocautery: a case report and review.
    Wilson S; Neustein SN; Camunas J
    Mt Sinai J Med; 2006 Oct; 73(6):880-3. PubMed ID: 17117315
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Syncopal monomorphic ventricular tachycardia with pleomorphism, sensitive to antitachycardia pacing in a patient with Brugada syndrome.
    Bertomeu-Gonzalez V; Ruiz-Granell R; García-Civera R; Morell-Cabedo S; Ferrero A
    Europace; 2006 Dec; 8(12):1048-50. PubMed ID: 17098780
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dislodged pacer lead causing ventricular tachycardia.
    Beer WM; Cherry DC; Goldenberg WD; DeMers G
    J Emerg Med; 2015 Jun; 48(6):e145-6. PubMed ID: 25858342
    [No Abstract]   [Full Text] [Related]  

  • 13. Infrequent syncope in a heavy vehicle driver.
    Chua R; Thomas SP
    Pacing Clin Electrophysiol; 2005 Apr; 28(4):346-7. PubMed ID: 15826275
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Occasional capture during ventricular loss of capture in a patient with permanent pacemaker: what is the mechanism?
    Cano O; Osca J; Sancho-Tello MJ; Olagüe J
    Pacing Clin Electrophysiol; 2010 Jun; 33(6):751-3. PubMed ID: 20230465
    [No Abstract]   [Full Text] [Related]  

  • 15. Mechanisms of syncopes in arrhythmogenic right ventricular dysplasia-cardiomyopathy beyond monomorphic ventricular tachycardia.
    Peters S; Trümmel M; Koehler B; Westermann KU
    Int J Cardiol; 2006 Jan; 106(1):52-4. PubMed ID: 16321666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Syncope in a pacemaker patient. Regular pacemaker follow-up is essential].
    Stiefelhagen P
    Fortschr Med; 1998 Aug; 116(22-23):33. PubMed ID: 9773597
    [No Abstract]   [Full Text] [Related]  

  • 17. A fatal device-device interaction between a wearable automated defibrillator and a unipolar ventricular pacemaker.
    LaPage MJ; Canter CE; Rhee EK
    Pacing Clin Electrophysiol; 2008 Jul; 31(7):912-5. PubMed ID: 18684292
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Unusual VDD-pacing.
    Schumann J; Kiencke S; Osswald S; Rickenbacher P
    Europace; 2007 Jan; 9(1):76-7. PubMed ID: 17224431
    [TBL] [Abstract][Full Text] [Related]  

  • 19. I've had a pacemaker for many years and have developed persistent atrial fibrillation (AF). In the past three years, I've also had episodes of ventricular tachycardia (VT). I had valve surgery six years ago and am concerned that the pacemaker lead may have been damaged during surgery. What should I know about a replacement pacemaker?
    Heart Advis; 2011 Mar; 14(3):8. PubMed ID: 22977931
    [No Abstract]   [Full Text] [Related]  

  • 20. Lead fracture presenting as an unusual combination of capture failure, oversensing and undersensing.
    Dalvi BV; Iyer SS; Thawani AJ; Vengsarkar AS
    Indian Heart J; 1987; 39(1):79-81. PubMed ID: 3450574
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.