BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 1618558)

  • 1. Femoral shaft fractures treated with plate fixation and interlocked nailing: a comparative retrospective study.
    van Niekerk JL; Schoots FJ
    Injury; 1992; 23(4):219-22. PubMed ID: 1618558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Augmentative plate fixation for the management of femoral nonunion with broken interlocking nail.
    Ueng SW; Shih CH
    J Trauma; 1998 Oct; 45(4):747-52. PubMed ID: 9783615
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Initial clinical experience with osteosynthesis of femoral shaft fractures with a newly developed intramedullary implant (claw interlocking nail)].
    Krettek C; Haas N; Mathys R; Tscherne H
    Unfallchirurg; 1991 Jan; 94(1):1-8. PubMed ID: 2028259
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intramedullary nailing of femoral shaft fractures. Part II: Fracture-healing with static interlocking fixation.
    Brumback RJ; Uwagie-Ero S; Lakatos RP; Poka A; Bathon GH; Burgess AR
    J Bone Joint Surg Am; 1988 Dec; 70(10):1453-62. PubMed ID: 3198669
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Exchange nailing with enhanced distal fixation is effective for the treatment of infraisthmal femoral nonunions.
    Kim JW; Yoon YC; Oh CW; Han SB; Sim JA; Oh JK
    Arch Orthop Trauma Surg; 2018 Jan; 138(1):27-34. PubMed ID: 28956142
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comminuted femoral-shaft fractures: treatment by roller traction, cerclage wires and an intramedullary nail, or an interlocking intramedullary nail.
    Johnson KD; Johnston DW; Parker B
    J Bone Joint Surg Am; 1984 Oct; 66(8):1222-35. PubMed ID: 6490697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures].
    Huang P; Tang PF; Yao Q; Liang YT; Tao S; Zhang Q; Guo YZ; Liang XD; Wang Y
    Zhongguo Gu Shang; 2008 Apr; 21(4):261-3. PubMed ID: 19102183
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Treatment for nonunion of the shaft of the humerus: comparison of plates and Seidel interlocking nails.
    Wu CC; Shih CH
    Can J Surg; 1992 Dec; 35(6):661-5. PubMed ID: 1458396
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Indication and technic of interlocking nailing of the femur].
    Maroske D; Thon K; Stroh M; Otto R
    Zentralbl Chir; 1984; 109(9):577-91. PubMed ID: 6741322
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Plate augmentation leaving the nail in situ and bone grafting for non-union of femoral shaft fractures.
    Choi YS; Kim KS
    Int Orthop; 2005 Oct; 29(5):287-90. PubMed ID: 16132986
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flexible interlocked nailing of pediatric femoral fractures: experience with a new flexible interlocking intramedullary nail compared with other fixation procedures.
    Jencikova-Celerin L; Phillips JH; Werk LN; Wiltrout SA; Nathanson I
    J Pediatr Orthop; 2008 Dec; 28(8):864-73. PubMed ID: 19034180
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Problems associated with longitudinal fractures of the femoral shaft in adults. A comparison between intramedullary nailing, interlocking intramedullary nailing and plating.
    Varjonen L; Majola A; Vainionpää S; Böstman O; Rokkanen P
    Ann Chir Gynaecol; 1990; 79(1):46-9. PubMed ID: 2357055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is augmentation plating an effective treatment for non-union of femoral shaft fractures with nail in situ?
    Jhunjhunwala HR; Dhawale AA
    Eur J Trauma Emerg Surg; 2016 Jun; 42(3):339-43. PubMed ID: 26038052
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Electromagnetic navigation interlocking intramedullary nail technology for treatment of femoral shaft fractures].
    Zuo K; Qin W; Guo Q; Palati-Ababaikeli ; Qiao P; Shen M; Yin L; Pan Q; Xu X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Oct; 28(10):1204-7. PubMed ID: 25591292
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interlocking intramedullary nail fixation with additional bone grafting from trochanter via a femoral hollow trephine in the treatment of femoral shaft fractures: design and clinical application.
    Liu Y; Zheng Y; Shen Z; Wang S; Wei X; Gu X; Zhan H; Kuang Y
    Int Orthop; 2017 Feb; 41(2):397-402. PubMed ID: 27234421
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Management of Humeral Shaft Fractures With Intramedullary Interlocking Nail Versus Locking Compression Plate.
    Fan Y; Li YW; Zhang HB; Liu JF; Han XM; Chang X; Weng XS; Lin J; Zhang BZ
    Orthopedics; 2015 Sep; 38(9):e825-9. PubMed ID: 26375542
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intramedullary nailing of femoral shaft fractures. Part III: Long-term effects of static interlocking fixation.
    Brumback RJ; Ellison TS; Poka A; Bathon GH; Burgess AR
    J Bone Joint Surg Am; 1992 Jan; 74(1):106-12. PubMed ID: 1733998
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Indications and outcomes of augmentation plating with decortication and autogenous bone grafting for femoral shaft nonunions.
    Park J; Yang KH
    Injury; 2013 Dec; 44(12):1820-5. PubMed ID: 23510754
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
    Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
    J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience.
    Nadkarni B; Srivastav S; Mittal V; Agarwal S
    J Trauma; 2008 Aug; 65(2):482-6. PubMed ID: 18695487
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.