These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

270 related articles for article (PubMed ID: 16193774)

  • 1. Dose distribution from x-ray microbeam arrays applied to radiation therapy: an EGS4 Monte Carlo study.
    De Felici M; Felici R; Sanchez del Rio M; Ferrero C; Bacarian T; Dilmanian FA
    Med Phys; 2005 Aug; 32(8):2455-63. PubMed ID: 16193774
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of dosimetrical quantities used in microbeam radiation therapy (MRT) with Monte Carlo simulations.
    Siegbahn EA; Stepanek J; Bräuer-Krisch E; Bravin A
    Med Phys; 2006 Sep; 33(9):3248-59. PubMed ID: 17022219
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microbeam radiation therapy: tissue dose penetration and BANG-gel dosimetry of thick-beams' array interlacing.
    Dilmanian FA; Romanelli P; Zhong Z; Wang R; Wagshul ME; Kalef-Ezra J; Maryanski MJ; Rosen EM; Anschel DJ
    Eur J Radiol; 2008 Dec; 68(3 Suppl):S129-36. PubMed ID: 18606516
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation.
    Chicilo F; Hanson AL; Geisler FH; Belev G; Edgar A; Ramaswami KO; Chapman D; Kasap SO
    Phys Med Biol; 2020 Apr; 65(7):075010. PubMed ID: 32242527
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams.
    Siegbahn EA; Bräuer-Krisch E; Bravin A; Nettelbeck H; Lerch ML; Rosenfeld AB
    Med Phys; 2009 Apr; 36(4):1128-37. PubMed ID: 19472618
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of the initial beam parameters in Monte Carlo linac simulation.
    Aljarrah K; Sharp GC; Neicu T; Jiang SB
    Med Phys; 2006 Apr; 33(4):850-8. PubMed ID: 16696460
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams.
    Tzedakis A; Damilakis JE; Mazonakis M; Stratakis J; Varveris H; Gourtsoyiannis N
    Med Phys; 2004 Apr; 31(4):907-13. PubMed ID: 15125009
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inclusion of compensator-induced scatter and beam filtration in pencil beam dose calculations.
    du Plessis FC; Willemse CA
    Med Phys; 2006 Aug; 33(8):2896-904. PubMed ID: 16964866
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo simulation of dose distributions from a synchrotron-produced microplanar beam array using the EGS4 code system.
    Orion I; Rosenfeld AB; Dilmanian FA; Telang F; Ren B; Namito Y
    Phys Med Biol; 2000 Sep; 45(9):2497-508. PubMed ID: 11008951
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The GEANT4 toolkit for microdosimetry calculations: application to microbeam radiation therapy (MRT).
    Spiga J; Siegbahn EA; Bräuer-Krisch E; Randaccio P; Bravin A
    Med Phys; 2007 Nov; 34(11):4322-30. PubMed ID: 18072497
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calculation of dose profiles in stereotactic synchrotron microplanar beam radiotherapy in a tissue-lung phantom.
    Company FZ
    Australas Phys Eng Sci Med; 2007 Mar; 30(1):33-41. PubMed ID: 17508599
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A high-resolution dose calculation engine for X-ray microbeams radiation therapy.
    Keshmiri S; Brocard S; Serduc R; Adam JF
    Med Phys; 2022 Jun; 49(6):3999-4017. PubMed ID: 35342953
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Physics study of microbeam radiation therapy with PSI-version of Monte Carlo code GEANT as a new computational tool.
    Stepanek J; Blattmann H; Laissue JA; Lyubimova N; Di Michiel M; Slatkin DN
    Med Phys; 2000 Jul; 27(7):1664-75. PubMed ID: 10947271
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc.
    Chow JC; Grigorov GN
    Med Phys; 2008 Apr; 35(4):1241-50. PubMed ID: 18491516
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy.
    Ohno Y; Torikoshi M; Suzuki M; Umetani K; Imai Y; Uesugi K; Yagi N
    Med Phys; 2008 Jul; 35(7):3252-8. PubMed ID: 18697550
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method.
    Titt U; Zheng Y; Vassiliev ON; Newhauser WD
    Phys Med Biol; 2008 Jan; 53(2):487-504. PubMed ID: 18185001
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monte Carlo dose enhancement studies in microbeam radiation therapy.
    Martínez-Rovira I; Prezadoa Y
    Med Phys; 2011 Jul; 38(7):4430-9. PubMed ID: 21859044
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo simulation of stereotactic microbeam radiation therapy: evaluation of the usage of a linear accelerator as the x-ray source.
    Gokeri G; Kocar C; Tombakoglu M; Cecen Y
    Phys Med Biol; 2013 Jul; 58(13):4621-42. PubMed ID: 23771153
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Proton microbeam radiotherapy with scanned pencil-beams--Monte Carlo simulations.
    Kłodowska M; Olko P; Waligórski MP
    Phys Med; 2015 Sep; 31(6):621-6. PubMed ID: 25982232
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.