These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 16195068)

  • 1. Pelvic tilt makes acetabular cup navigation inaccurate.
    Lembeck B; Mueller O; Reize P; Wuelker N
    Acta Orthop; 2005 Aug; 76(4):517-23. PubMed ID: 16195068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The rationale for tilt-adjusted acetabular cup navigation.
    Babisch JW; Layher F; Amiot LP
    J Bone Joint Surg Am; 2008 Feb; 90(2):357-65. PubMed ID: 18245596
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pelvic tilt measurement before and after total hip arthroplasty.
    Blondel B; Parratte S; Tropiano P; Pauly V; Aubaniac JM; Argenson JN
    Orthop Traumatol Surg Res; 2009 Dec; 95(8):568-72. PubMed ID: 19910273
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pelvic position, lying on a traction table, during THA by direct anterior approach. Comparison with the standing position and influence on the acetabular cup anteversion.
    Auberger G; Pansard E; Bouche PA; Marmorat JL; Judet T; Lonjon G
    Orthop Traumatol Surg Res; 2021 Dec; 107(8):103077. PubMed ID: 34563732
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Conventional cup navigation with 2D fluoroscopy in THA: accurate cup positioning respecting pelvic tilt].
    Pichl J; Kremer M; Hoffmann R
    Z Orthop Unfall; 2011 Oct; 149(5):510-7. PubMed ID: 21480171
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.
    Schwarz TJ; Weber M; Dornia C; Worlicek M; Renkawitz T; Grifka J; Craiovan B
    Rofo; 2017 Sep; 189(9):864-873. PubMed ID: 28697529
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Implant position calculation for acetabular cup placement considering pelvic lateral tilt and inclination.
    Chen E; Goertz W; Lill CA
    Comput Aided Surg; 2006 Nov; 11(6):309-16. PubMed ID: 17458765
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Functional acetabular component position with supine total hip replacement.
    Eilander W; Harris SJ; Henkus HE; Cobb JP; Hogervorst T
    Bone Joint J; 2013 Oct; 95-B(10):1326-31. PubMed ID: 24078527
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Pelvic Tilt and Rotation on Cup Orientation in Both Supine and Standing Positions.
    Yun H; Murphy WS; Ward DM; Zheng G; Hayden BL; Murphy SB
    J Arthroplasty; 2018 May; 33(5):1442-1448. PubMed ID: 29276116
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Normative 3D acetabular orientation measurements by the low-dose EOS imaging system in 102 asymptomatic subjects in standing position: Analyses by side, gender, pelvic incidence and reproducibility.
    Thelen T; Thelen P; Demezon H; Aunoble S; Le Huec JC
    Orthop Traumatol Surg Res; 2017 Apr; 103(2):209-215. PubMed ID: 28025151
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of pelvic tilt and rotation on cup orientation in standing anteroposterior radiographs.
    Yun HH; Murphy WS; Ward DM; Zheng G; Hayden B; Murphy SB
    Hip Int; 2020 Jan; 30(1):48-55. PubMed ID: 30834795
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro investigation of the influence of pelvic tilt on acetabular cup alignment.
    Kalteis TA; Handel M; Herbst B; Grifka J; Renkawitz T
    J Arthroplasty; 2009 Jan; 24(1):152-7. PubMed ID: 18977116
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.
    Derbyshire B
    Proc Inst Mech Eng H; 2018 Mar; 232(3):299-309. PubMed ID: 29473454
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Quantification and visualization of the influence of pelvic tilt upon measurement of acetabular inclination and anteversion].
    Müller O; Lembeck B; Reize P; Wülker N
    Z Orthop Ihre Grenzgeb; 2005; 143(1):72-8. PubMed ID: 15754235
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variation in functional pelvic tilt in patients undergoing total hip arthroplasty.
    Pierrepont J; Hawdon G; Miles BP; Connor BO; Baré J; Walter LR; Marel E; Solomon M; McMahon S; Shimmin AJ
    Bone Joint J; 2017 Feb; 99-B(2):184-191. PubMed ID: 28148659
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative Effect of Pelvic Position on Radiographic Assessment of Acetabular Component Position.
    Delagrammaticas DE; Alvi HM; Kaat AJ; Sullivan RR; Stover MD; Manning DW
    J Arthroplasty; 2018 Feb; 33(2):608-614.e1. PubMed ID: 29066106
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changes of acetabular anteversion according to pelvic tilt on sagittal plane under various acetabular inclinations.
    Song SK; Choi WK; Jung SH; Kim HC; Kim TH; Cho MR
    J Orthop Res; 2021 Apr; 39(4):806-812. PubMed ID: 32603527
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Course of pelvic lift during total hip arthroplasty.
    Brodt S; Nowack D; Krakow L; Windisch C; Matziolis G
    Arch Orthop Trauma Surg; 2017 Jan; 137(1):129-133. PubMed ID: 27896435
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of a CT image based software for three-dimensional measurement of acetabular cup orientation.
    Wassilew GI; Janz V; Heller M; Wenzl M; Perka C; Hasart O
    Technol Health Care; 2011; 19(3):185-93. PubMed ID: 21957510
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: spatial orientation of the pelvis in different positions.
    Mayr E; Kessler O; Prassl A; Rachbauer F; Krismer M; Nogler M
    Acta Orthop; 2005 Dec; 76(6):848-53. PubMed ID: 16470440
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.