BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

299 related articles for article (PubMed ID: 16199169)

  • 1. The light-addressable potentiometric sensor for multi-ion sensing and imaging.
    Yoshinobu T; Iwasaki H; Ui Y; Furuichi K; Ermolenko Y; Mourzina Y; Wagner T; Näther N; Schöning MJ
    Methods; 2005 Sep; 37(1):94-102. PubMed ID: 16199169
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficient Illumination for a Light-Addressable Potentiometric Sensor.
    Yoshinobu T; Miyamoto KI
    Sensors (Basel); 2022 Jun; 22(12):. PubMed ID: 35746324
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bio-initiated light addressable potentiometric sensor for unlabeled biodetection and its MEDICI simulation.
    Jia Y; Gao C; Feng D; Wu M; Liu Y; Chen X; Xing K; Feng X
    Analyst; 2011 Nov; 136(21):4533-8. PubMed ID: 21922098
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High dielectric constant PrY(x)O(y) sensing films electrolyte-insulator-semiconductor pH-sensor for the detection of urea.
    Wu MH; Lee CD; Pan TM
    Anal Chim Acta; 2009 Sep; 651(1):36-41. PubMed ID: 19733732
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of information visualization methods eliminating cross talk in multiple sensing units investigated for a light-addressable potentiometric sensor.
    Siqueira JR; Maki RM; Paulovich FV; Werner CF; Poghossian A; de Oliveira MC; Zucolotto V; Oliveira ON; Schöning MJ
    Anal Chem; 2010 Jan; 82(1):61-5. PubMed ID: 20041720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Graphene oxide modified light addressable potentiometric sensor and its application for ssDNA monitoring.
    Jia Y; Yin XB; Zhang J; Zhou S; Song M; Xing KL
    Analyst; 2012 Dec; 137(24):5866-73. PubMed ID: 23113318
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of heavy metal toxicity using cardiac cell-based biosensor.
    Liu Q; Cai H; Xu Y; Xiao L; Yang M; Wang P
    Biosens Bioelectron; 2007 Jun; 22(12):3224-9. PubMed ID: 17416514
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Label-free biosensor: a novel phage-modified Light Addressable Potentiometric Sensor system for cancer cell monitoring.
    Jia Y; Qin M; Zhang H; Niu W; Li X; Wang L; Li X; Bai Y; Cao Y; Feng X
    Biosens Bioelectron; 2007 Jun; 22(12):3261-6. PubMed ID: 17329093
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Light-Addressable Potentiometric Sensors Using ZnO Nanorods as the Sensor Substrate for Bioanalytical Applications.
    Tu Y; Ahmad N; Briscoe J; Zhang DW; Krause S
    Anal Chem; 2018 Jul; 90(14):8708-8715. PubMed ID: 29932632
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Studies of Functional Nucleic Acids Modified Light Addressable Potentiometric Sensors: X-ray Photoelectron Spectroscopy, Biochemical Assay, and Simulation.
    Jia Y; Li F
    Anal Chem; 2018 Apr; 90(8):5153-5161. PubMed ID: 29561137
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cell-based biosensors based on light-addressable potentiometric sensors for single cell monitoring.
    Xu G; Ye X; Qin L; Xu Y; Li Y; Li R; Wang P
    Biosens Bioelectron; 2005 Mar; 20(9):1757-63. PubMed ID: 15681191
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Label-free detection of DNA using novel organic-based electrolyte-insulator-semiconductor.
    Lin TW; Kekuda D; Chu CW
    Biosens Bioelectron; 2010 Aug; 25(12):2706-10. PubMed ID: 20483584
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of immunofiltration assay by light addressable potentiometric sensor with genetically biotinylated recombinant antibody for rapid identification of Venezuelan equine encephalitis virus.
    Hu WG; Thompson HG; Alvi AZ; Nagata LP; Suresh MR; Fulton RE
    J Immunol Methods; 2004 Jun; 289(1-2):27-35. PubMed ID: 15251409
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influences of Probe's Morphology for Metal Ion Detection Based on Light-Addressable Potentiometric Sensors.
    Shao C; Zhou S; Yin X; Gu Y; Jia Y
    Sensors (Basel); 2016 May; 16(5):. PubMed ID: 27187412
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A urea biosensor based on pH-sensitive Sm2TiO5 electrolyte-insulator-semiconductor.
    Pan TM; Huang MD; Lin WY; Wu MH
    Anal Chim Acta; 2010 Jun; 669(1-2):68-74. PubMed ID: 20510905
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Light addressable potentiometric sensor with well-ordered pyramidal pits-patterned silicon.
    Tan J; Liu S; Luo J; Chen Y; Zhao W; Li H; Li G; Li X
    Anal Chim Acta; 2023 Jan; 1238():340599. PubMed ID: 36464443
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Can the light-addressable potentiometric sensor (LAPS) detect extracellular potentials of cardiac myocytes?
    Parak WJ; George M; Domke J; Radmacher M; Behrends JC; Denyer MC; Gaub HE
    IEEE Trans Biomed Eng; 2000 Aug; 47(8):1106-13. PubMed ID: 10943060
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel design of multifunctional integrated cell-based biosensors for simultaneously detecting cell acidification and extracellular potential.
    Yu H; Cai H; Zhang W; Xiao L; Liu Q; Wang P
    Biosens Bioelectron; 2009 Jan; 24(5):1462-8. PubMed ID: 18929479
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Light-Addressable Electrochemical Sensors toward Spatially Resolved Biosensing and Imaging Applications.
    Meng Y; Chen F; Wu C; Krause S; Wang J; Zhang DW
    ACS Sens; 2022 Jul; 7(7):1791-1807. PubMed ID: 35762514
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and characterization of an all-solid-state potentiometric biosensor array microfluidic device for multiple ion analysis.
    Liao WY; Weng CH; Lee GB; Chou TC
    Lab Chip; 2006 Oct; 6(10):1362-8. PubMed ID: 17102850
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.