BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 16200267)

  • 1. [Safety and feasibility of dobutamine-atropine stress echocardiography in octogenarian patients].
    Abreu JS; Diógenes TC; Farias AG; Morais JM; Paes Júnior JN
    Arq Bras Cardiol; 2005 Sep; 85(3):198-204. PubMed ID: 16200267
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Safety of dobutamine-atropine stress echocardiography: A prospective experience of 4,033 consecutive studies.
    Mathias W; Arruda A; Santos FC; Arruda AL; Mattos E; Osório A; Campos O; Gil M; Andrade JL; Carvalho AC
    J Am Soc Echocardiogr; 1999 Oct; 12(10):785-91. PubMed ID: 10511646
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Isometric handgrip exercise during dobutamine-atropine stress echocardiography increases heart rate acceleration and decreases study duration and dobutamine and atropine dosage.
    Yao SS; Moldenhauer S; Sherrid MV
    Clin Cardiol; 2003 May; 26(5):238-42. PubMed ID: 12769253
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of safety and efficacy of the early injection of atropine during dobutamine stress echocardiography with the conventional protocol.
    Tsutsui JM; Osório AF; Lario FA; Fernandes DR; Sodre G; Andrade JL; Ramires JA; Mathias W
    Am J Cardiol; 2004 Dec; 94(11):1367-72. PubMed ID: 15566905
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of dobutamine-atropine stress echocardiography in prognostic evaluation of 300 women.
    Cordovil A; Júnior WM; Andrade JL; Filho OC; Moisés VA; Gil MA; Machado CV; Arruda AM; Paiva MG; Carvalho AC; de Paola AA
    Echocardiography; 2004 Feb; 21(2):113-8. PubMed ID: 14961788
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the diagnostic potential of four echocardiographic stress tests shortly after acute myocardial infarction: submaximal exercise, transesophageal atrial pacing, dipyridamole, and dobutamine-atropine.
    Schröder K; Völler H; Dingerkus H; Münzberg H; Dissmann R; Linderer T; Schultheiss HP
    Am J Cardiol; 1996 May; 77(11):909-14. PubMed ID: 8644637
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Safety and feasibility of dobutamine-atropine stress echocardiography for the diagnosis of coronary artery disease in diabetic patients unable to perform an exercise stress test.
    Elhendy A; van Domburg RT; Poldermans D; Bax JJ; Nierop PR; Geleijnse ML; Roelandt JR
    Diabetes Care; 1998 Nov; 21(11):1797-802. PubMed ID: 9802723
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Safety and feasibility of dobutamine-atropine stress echocardiography].
    Mathias Júnior W; Beneti LP; dos Santos FC; Duprat R; Beraldo A; Gil MA; Andrade JL; Martinez E
    Arq Bras Cardiol; 1997 Jul; 69(1):31-4. PubMed ID: 9532813
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Between observer variation is not eliminated by standardised analysis of dobutamine-atropine stress echocardiography.
    Carstensen S; Bundgaard H; Kjøller-Hansen L; Atar D; Ali SM; Saunamäki K; Kelbaek H
    Int J Cardiovasc Imaging; 2002 Jun; 18(3):169-79. PubMed ID: 12123308
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety, hemodynamic profile, and feasibility of dobutamine stress technetium myocardial perfusion single-photon emission CT imaging for evaluation of coronary artery disease in the elderly.
    Elhendy A; van Domburg RT; Bax JJ; Valkema R; Reijs AE; Krenning EP; Roelandt JR
    Chest; 2000 Mar; 117(3):649-56. PubMed ID: 10712987
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Safety of myocardial flash-contrast echocardiography in combination with dobutamine stress testing for the detection of ischaemia in 5250 studies.
    Aggeli C; Giannopoulos G; Roussakis G; Christoforatou E; Marinos G; Toli C; Pitsavos C; Stefanadis C
    Heart; 2008 Dec; 94(12):1571-7. PubMed ID: 18474538
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Feasibility, safety and accuracy of dobutamine/atropine stress echocardiography for the detection of coronary artery disease in renal transplant candidates.
    Ferreira PA; de Lima VC; Campos Filho O; Gil MA; Cordovil A; Machado CV; Pestana JO; Carvalho AC
    Arq Bras Cardiol; 2007 Jan; 88(1):45-51. PubMed ID: 17364118
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety and cardiac chronotropic responsiveness to the early injection of atropine during dobutamine stress echocardiography in the elderly.
    Tsutsui JM; Lario FC; Fernandes DR; Kowatsch I; Sbano JC; Franchini Ramires JA; Mathias W
    Heart; 2005 Dec; 91(12):1563-7. PubMed ID: 15797935
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Atropine first is safer than conventional atropine administration in older people undergoing dobutamine stress echocardiography.
    Shehata M
    Ther Adv Cardiovasc Dis; 2014 Oct; 8(5):176-84. PubMed ID: 24906705
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Safety and feasibility of dobutamine-atropine stress echocardiography in patients with ischemic left ventricular dysfunction.
    Cornel JH; Balk AH; Boersma E; Maat AP; Elhendy A; Arnese M; Salustri A; Roelandt JR; Fioretti PM
    J Am Soc Echocardiogr; 1996; 9(1):27-32. PubMed ID: 8679234
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dipyridamole and dobutamine-atropine stress echocardiography in the diagnosis of coronary artery disease. Comparison with exercise stress test, analysis of agreement, and impact of antianginal treatment.
    San Román JA; Vilacosta I; Castillo JA; Rollán MJ; Peral V; Sánchez-Harguindey L; Fernández-Avilés F
    Chest; 1996 Nov; 110(5):1248-54. PubMed ID: 8915229
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safety of dobutamine-atropine stress echocardiography in patients with suspected or proven coronary artery disease.
    Poldermans D; Fioretti PM; Boersma E; Forster T; van Urk H; Cornel JH; Arnese M; Roelandt RT
    Am J Cardiol; 1994 Mar; 73(7):456-9. PubMed ID: 8141086
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Complications of stress-echocardiography used for diagnosis of ischemic heart disease].
    Mikheev NN
    Kardiologiia; 2008; 48(1):19-23. PubMed ID: 18260991
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Prognostic value of stress echocardiography by dobutamine combined with atropine].
    Mathias Júnior W; Stella U; Baruta F; Cordovil A; Andrade JL; Carvalho AC; Ribeiro E; Duprat R; Martinez E
    Arq Bras Cardiol; 1997 Aug; 69(2):95-9. PubMed ID: 9567331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safety and utility of atropine addition during dobutamine stress echocardiography for the assessment of viable myocardium in patients with severe left ventricular dysfunction.
    Poldermans D; Rambaldi R; Bax JJ; Cornel JH; Thomson IR; Valkema R; Boersma E; Fioretti PM; Breburda CS; Roelandt JR
    Eur Heart J; 1998 Nov; 19(11):1712-8. PubMed ID: 9857925
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.