BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

274 related articles for article (PubMed ID: 16200759)

  • 1. Joint angle control by FES using a feedback error learning controller.
    Kurosawa K; Futami R; Watanabe T; Hoshimiya N
    IEEE Trans Neural Syst Rehabil Eng; 2005 Sep; 13(3):359-71. PubMed ID: 16200759
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A neuro-control system for the knee joint position control with quadriceps stimulation.
    Chang GC; Luh JJ; Liao GD; Lai JS; Cheng CK; Kuo BL; Kuo TS
    IEEE Trans Rehabil Eng; 1997 Mar; 5(1):2-11. PubMed ID: 9086380
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implementation of a physiologically identified PD feedback controller for regulating the active ankle torque during quiet stance.
    Vette AH; Masani K; Popovic MR
    IEEE Trans Neural Syst Rehabil Eng; 2007 Jun; 15(2):235-43. PubMed ID: 17601193
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Functional electrical stimulation controlled by artificial neural networks: pilot experiments with simple movements are promising for rehabilitation applications.
    Ferrante S; Pedrocchi A; IannĂ² M; De Momi E; Ferrarin M; Ferrigno G
    Funct Neurol; 2004; 19(4):243-52. PubMed ID: 15776793
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Functional restoration of elbow extension after spinal-cord injury using a neural network-based synergistic FES controller.
    Giuffrida JP; Crago PE
    IEEE Trans Neural Syst Rehabil Eng; 2005 Jun; 13(2):147-52. PubMed ID: 16003892
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neural network and fuzzy control in FES-assisted locomotion for the hemiplegic.
    Chen YL; Chen SC; Chen WL; Hsiao CC; Kuo TS; Lai JS
    J Med Eng Technol; 2004; 28(1):32-8. PubMed ID: 14660183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sliding mode closed-loop control of FES: controlling the shank movement.
    Jezernik S; Wassink RG; Keller T
    IEEE Trans Biomed Eng; 2004 Feb; 51(2):263-72. PubMed ID: 14765699
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A study on feedback error learning controller for functional electrical stimulation: generation of target trajectories by minimum jerk model.
    Watanabe T; Fukushima K
    Artif Organs; 2011 Mar; 35(3):270-4. PubMed ID: 21401673
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Neural network control of functional neuromuscular stimulation systems: computer simulation studies.
    Abbas JJ; Chizeck HJ
    IEEE Trans Biomed Eng; 1995 Nov; 42(11):1117-27. PubMed ID: 7498916
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design of a torque-controlled manipulator to analyse the admittance of the wrist joint.
    Schouten AC; de Vlugt E; van Hilten JJ; van der Helm FC
    J Neurosci Methods; 2006 Jun; 154(1-2):134-41. PubMed ID: 16434105
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel theoretical framework for the dynamic stability analysis, movement control, and trajectory generation in a multisegment biomechanical model.
    Iqbal K; Roy A
    J Biomech Eng; 2009 Jan; 131(1):011002. PubMed ID: 19045918
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Model-based control of FES-induced single joint movements.
    Ferrarin M; Palazzo F; Riener R; Quintern J
    IEEE Trans Neural Syst Rehabil Eng; 2001 Sep; 9(3):245-57. PubMed ID: 11561660
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Strategies for generating prolonged functional standing using intramuscular stimulation or intraspinal microstimulation.
    Lau B; Guevremont L; Mushahwar VK
    IEEE Trans Neural Syst Rehabil Eng; 2007 Jun; 15(2):273-85. PubMed ID: 17601198
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nonlinear modeling of FES-supported standing-up in paraplegia for selection of feedback sensors.
    Kamnik R; Shi JQ; Murray-Smith R; Bajd T
    IEEE Trans Neural Syst Rehabil Eng; 2005 Mar; 13(1):40-52. PubMed ID: 15813405
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Surface myoelectric signal classification for prostheses control.
    Al-Assaf Y; Al-Nashash H
    J Med Eng Technol; 2005; 29(5):203-7. PubMed ID: 16126579
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New control strategies for neuroprosthetic systems.
    Crago PE; Lan N; Veltink PH; Abbas JJ; Kantor C
    J Rehabil Res Dev; 1996 Apr; 33(2):158-72. PubMed ID: 8724171
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fuzzy FES controller using cycle-to-cycle control for repetitive movement training in motor rehabilitation. Experimental tests with wireless system.
    Miura N; Watanabe T; Sugimoto S; Seki K; Kanai H
    J Med Eng Technol; 2011; 35(6-7):314-21. PubMed ID: 21767134
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improving signal reliability for on-line joint angle estimation from nerve cuff recordings of muscle afferents.
    Jensen W; Sinkjaer T; Sepulveda F
    IEEE Trans Neural Syst Rehabil Eng; 2002 Sep; 10(3):133-9. PubMed ID: 12503777
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An elbow joint movement control model with visual feedback.
    Xiao S; Li X
    Biomed Sci Instrum; 1997; 34():218-23. PubMed ID: 9603042
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comments on "Sliding mode closed-loop control of FES: controlling the shank movement".
    Ebrahimpour MM; Erfanian A
    IEEE Trans Biomed Eng; 2008 Dec; 55(12):2842-3. PubMed ID: 19126468
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.