These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 1620462)

  • 1. [The physiopathology of oxygen venous saturation].
    Tufano R; Gravino E; Pezza M
    Minerva Anestesiol; 1992 Apr; 58(4 Suppl 1):5-13. PubMed ID: 1620462
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SvO2 monitoring: tool for evaluating patient outcomes.
    Cathelyn JL; Samples DA
    Dimens Crit Care Nurs; 1998; 17(2):58-63; quiz 64-6. PubMed ID: 9624946
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adequate agreement between venous oxygen saturation in right atrium and pulmonary artery in critically ill children.
    Pérez AC; Eulmesekian PG; Minces PG; Schnitzler EJ
    Pediatr Crit Care Med; 2009 Jan; 10(1):76-9. PubMed ID: 19057448
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The fiber optic Swan-Ganz catheter. The monitoring of SvO2].
    Solé Fábregas A; Salas Campos L
    Rev Enferm; 1994 May; 17(189):75-9. PubMed ID: 8009165
    [No Abstract]   [Full Text] [Related]  

  • 5. Continuous monitoring of mixed venous saturation (SvO2): an adjunct to nursing assessment?
    Proctor M
    Intensive Crit Care Nurs; 1992 Jun; 8(2):66-70. PubMed ID: 1611288
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The physiologic basis for continuous mixed venous oxygen saturation monitoring.
    White KM; Winslow EH; Clark AP; Tyler DO
    Heart Lung; 1990 Sep; 19(5 Pt 2):548-51. PubMed ID: 2211165
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous monitoring of mixed venous oxygen saturation in critically ill patients.
    Baele PL; McMichan JC; Marsh HM; Sill JC; Southorn PA
    Anesth Analg; 1982 Jun; 61(6):513-7. PubMed ID: 7200741
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hepatic venous catheterization in patients undergoing positive end-expiratory pressure ventilation after OLT: technique and clinical impact.
    Kaisers U; Langrehr JM; Haack M; Mohnhaupt A; Neuhaus P; Rossaint R
    Clin Transplant; 1995 Aug; 9(4):301-6. PubMed ID: 7579737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Continuous monitoring of mixed venous blood oxygen saturation].
    Journois D; Safran D
    Ann Fr Anesth Reanim; 1993; 12(4):393-408. PubMed ID: 8273928
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Venous oxygen saturation and lactate gradient from superior vena cava to pulmonary artery in patients with septic shock.
    Kopterides P; Bonovas S; Mavrou I; Kostadima E; Zakynthinos E; Armaganidis A
    Shock; 2009 Jun; 31(6):561-7. PubMed ID: 18838939
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Continuous measurement of mixed venous oxygen saturation].
    Hannemann L; Reinhart K
    Acta Med Austriaca; 1993; 20(4):107-11. PubMed ID: 8237280
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Role of oxygen venous saturation monitoring and CAVH in the multiple organ failure syndrome. Description of a clinical case].
    Costa P; Gulotta G; Agrò C; Romano V; Papa G; Piazza F; Sparacia B; Sansone A
    Minerva Anestesiol; 1992 May; 58(5):311-4. PubMed ID: 1635644
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Continuous monitoring of mixed venous oxygen saturation during exercise using fiberoptic pulmonary artery catheter].
    Nakanishi N; Yoshioka T; Hashizume T; Nonogi H; Okubo S; Shimouchi A; Saito M
    Kokyu To Junkan; 1990 Aug; 38(8):799-804. PubMed ID: 2218089
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Perspectives on the interpretation of continuous mixed venous oxygen saturation.
    Enger EL; Holm K
    Heart Lung; 1990 Sep; 19(5 Pt 2):578-80. PubMed ID: 2211172
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Physiologic rationale of Sv-O2 monitoring.
    Mims BC
    Crit Care Nurs Clin North Am; 1989 Sep; 1(3):619-28. PubMed ID: 2684246
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical use of continuous monitoring of mixed venous oxygen saturation during and after cardiovascular surgery.
    Baele P; Goenen M; Kestens-Servaye Y
    Acta Anaesthesiol Belg; 1985 Mar; 36(1):5-13. PubMed ID: 4013634
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Central venous and mixed venous oxygen saturation in critically ill patients.
    Ladakis C; Myrianthefs P; Karabinis A; Karatzas G; Dosios T; Fildissis G; Gogas J; Baltopoulos G
    Respiration; 2001; 68(3):279-85. PubMed ID: 11416249
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical implications of intraoperative continuous mixed venous oxygen saturation monitoring.
    Naruns EB
    AANA J; 1989 Feb; 57(1):45-52. PubMed ID: 2929243
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [From central venous pressure to SVO2].
    Neidhardt M; Mourand JL
    Agressologie; 1992; 33 Spec No 1():46-8. PubMed ID: 1306942
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Factors influencing mixed venous oxygen saturation in intensive care].
    Rouby JJ; Poète P; Bodin L; Bourgeois JL; Arthaud M; Devilliers C; Viars P
    Ann Fr Anesth Reanim; 1989; 8(6):703-7. PubMed ID: 2699177
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.