These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

353 related articles for article (PubMed ID: 16212436)

  • 1. Chemically modified, immobilized trypsin reactor with improved digestion efficiency.
    Freije JR; Mulder PP; Werkman W; Rieux L; Niederlander HA; Verpoorte E; Bischoff R
    J Proteome Res; 2005; 4(5):1805-13. PubMed ID: 16212436
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of microwave-assisted protein digestion based on trypsin-immobilized magnetic microspheres for highly efficient proteolysis followed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis.
    Lin S; Lin Z; Yao G; Deng C; Yang P; Zhang X
    Rapid Commun Mass Spectrom; 2007; 21(23):3910-8. PubMed ID: 17990248
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pressure-assisted tryptic digestion using a syringe.
    Yang HJ; Hong J; Lee S; Shin S; Kim J; Kim J
    Rapid Commun Mass Spectrom; 2010 Apr; 24(7):901-8. PubMed ID: 20196188
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rheostatic control of tryptic digestion in a microscale fluidic system.
    Percy AJ; Schriemer DC
    Anal Chim Acta; 2010 Jan; 657(1):53-9. PubMed ID: 19951757
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Integration of immobilized trypsin bead beds for protein digestion within a microfluidic chip incorporating capillary electrophoresis separations and an electrospray mass spectrometry interface.
    Wang C; Oleschuk R; Ouchen F; Li J; Thibault P; Harrison DJ
    Rapid Commun Mass Spectrom; 2000; 14(15):1377-83. PubMed ID: 10920358
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A hydrophilic immobilized trypsin reactor with N-vinyl-2-pyrrolidinone modified polymer microparticles as matrix for highly efficient protein digestion with low peptide residue.
    Jiang H; Yuan H; Liang Y; Xia S; Zhao Q; Wu Q; Zhang L; Liang Z; Zhang Y
    J Chromatogr A; 2012 Jul; 1246():111-6. PubMed ID: 22446077
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis.
    Govorukhina NI; Reijmers TH; Nyangoma SO; van der Zee AG; Jansen RC; Bischoff R
    J Chromatogr A; 2006 Jul; 1120(1-2):142-50. PubMed ID: 16574134
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A capillary monolithic trypsin reactor for efficient protein digestion in online and offline coupling to ESI and MALDI mass spectrometry.
    Spross J; Sinz A
    Anal Chem; 2010 Feb; 82(4):1434-43. PubMed ID: 20099804
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficient and specific trypsin digestion of microgram to nanogram quantities of proteins in organic-aqueous solvent systems.
    Strader MB; Tabb DL; Hervey WJ; Pan C; Hurst GB
    Anal Chem; 2006 Jan; 78(1):125-34. PubMed ID: 16383319
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the possible proteomic application of trypsin from Streptomyces griseus.
    Stosová T; Sebela M; Rehulka P; Sedo O; Havlis J; Zdráhal Z
    Anal Biochem; 2008 May; 376(1):94-102. PubMed ID: 18261455
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fast and efficient proteolysis by microwave-assisted protein digestion using trypsin-immobilized magnetic silica microspheres.
    Lin S; Yao G; Qi D; Li Y; Deng C; Yang P; Zhang X
    Anal Chem; 2008 May; 80(10):3655-65. PubMed ID: 18407620
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hydrophilic immobilized trypsin reactor with magnetic graphene oxide as support for high efficient proteome digestion.
    Jiang B; Yang K; Zhao Q; Wu Q; Liang Z; Zhang L; Peng X; Zhang Y
    J Chromatogr A; 2012 Sep; 1254():8-13. PubMed ID: 22871380
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Immobilization of trypsin on superparamagnetic nanoparticles for rapid and effective proteolysis.
    Li Y; Xu X; Deng C; Yang P; Zhang X
    J Proteome Res; 2007 Sep; 6(9):3849-55. PubMed ID: 17676785
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On-column digestion of proteins in aqueous-organic solvents.
    Slysz GW; Schriemer DC
    Rapid Commun Mass Spectrom; 2003; 17(10):1044-50. PubMed ID: 12720284
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Integration of on-line protein digestion by trypsin in CZE by means of electrophoretically mediated microanalysis.
    Zeisbergerová M; Adámková A; Glatz Z
    Electrophoresis; 2009 Jul; 30(13):2378-84. PubMed ID: 19572323
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On-chip enzymatic microreactor using trypsin-immobilized superparamagnetic nanoparticles for highly efficient proteolysis.
    Liu J; Lin S; Qi D; Deng C; Yang P; Zhang X
    J Chromatogr A; 2007 Dec; 1176(1-2):169-77. PubMed ID: 18021785
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel microwave-assisted digestion by trypsin-immobilized magnetic nanoparticles for proteomic analysis.
    Lin S; Yun D; Qi D; Deng C; Li Y; Zhang X
    J Proteome Res; 2008 Mar; 7(3):1297-307. PubMed ID: 18257514
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Integration of an on-line protein digestion microreactor to a nanoelectrospray emitter for peptide mapping.
    Zhao C; Jiang H; Smith DR; Bruckenstein S; Wood TD
    Anal Biochem; 2006 Dec; 359(2):167-75. PubMed ID: 17078919
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultra fast trypsin digestion of proteins by high intensity focused ultrasound.
    López-Ferrer D; Capelo JL; Vázquez J
    J Proteome Res; 2005; 4(5):1569-74. PubMed ID: 16212408
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Integrated device for online sample buffer exchange, protein enrichment, and digestion.
    Sun L; Ma J; Qiao X; Liang Y; Zhu G; Shan Y; Liang Z; Zhang L; Zhang Y
    Anal Chem; 2010 Mar; 82(6):2574-9. PubMed ID: 20151663
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.