BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 16217844)

  • 21. Silicon micropillar array electrospray chip for drug and biomolecule analysis.
    Nissilä T; Sainiemi L; Sikanen T; Kotiaho T; Franssila S; Kostiainen R; Ketola RA
    Rapid Commun Mass Spectrom; 2007; 21(22):3677-82. PubMed ID: 17957810
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Coupling a microchip with electrospray ionization quadrupole time-of-flight mass spectrometer for peptide separation and identification.
    Li HF; Liu J; Cai Z; Lin JM
    Electrophoresis; 2008 May; 29(9):1889-94. PubMed ID: 18393336
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Analytical characterization of microfabricated SU-8 emitters for electrospray ionization mass spectrometry.
    Sikanen T; Tuomikoski S; Ketola RA; Kostiainen R; Franssila S; Kotiaho T
    J Mass Spectrom; 2008 Jun; 43(6):726-35. PubMed ID: 18205241
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of a two-dimensional liquid chromatography/mass spectrometry approach with a chip-based nanoelectrospray device for structural elucidation of metabolites in a human ADME study using a quadrupole time-of-flight mass spectrometer.
    Trunzer M; Graf D; Kiffe M
    Rapid Commun Mass Spectrom; 2007; 21(6):937-44. PubMed ID: 17295360
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Improvement of performance in label-free quantitative proteome analysis with monolithic electrospray ionization emitter.
    Wang F; Ye M; Dong J; Tian R; Hu L; Han G; Jiang X; Wu R; Zou H
    J Sep Sci; 2008 Aug; 31(14):2589-97. PubMed ID: 18693305
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Patterning, integration and characterisation of polymer optical oxygen sensors for microfluidic devices.
    Nock V; Blaikie RJ; David T
    Lab Chip; 2008 Aug; 8(8):1300-7. PubMed ID: 18651072
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Electrospray ionization from a gap with adjustable width.
    Ek P; Sjödahl J; Roeraade J
    Rapid Commun Mass Spectrom; 2006; 20(21):3176-82. PubMed ID: 17016803
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Ultralow-volume fraction collection from NanoLC columns for mass spectrometric analysis of protein phosphorylation and glycosylation.
    Corso TN; Van Pelt CK; Li J; Ptak C; Huang X
    Anal Chem; 2006 Apr; 78(7):2209-19. PubMed ID: 16579599
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A new on-chip ESI nozzle for coupling of MS with microfluidic devices.
    Schilling M; Nigge W; Rudzinski A; Neyer A; Hergenroder R
    Lab Chip; 2004 Jun; 4(3):220-4. PubMed ID: 15159782
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Microfluidic platform for liquid chromatography-tandem mass spectrometry analyses of complex peptide mixtures.
    Xie J; Miao Y; Shih J; Tai YC; Lee TD
    Anal Chem; 2005 Nov; 77(21):6947-53. PubMed ID: 16255594
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Flow injection based microfluidic device with carbon nanotube electrode for rapid salbutamol detection.
    Karuwan C; Wisitsoraat A; Maturos T; Phokharatkul D; Sappat A; Jaruwongrungsee K; Lomas T; Tuantranont A
    Talanta; 2009 Sep; 79(4):995-1000. PubMed ID: 19615498
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A decade of microfluidic analysis coupled with electrospray mass spectrometry: an overview.
    Koster S; Verpoorte E
    Lab Chip; 2007 Nov; 7(11):1394-412. PubMed ID: 17960264
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Microstructured photonic fibers as multichannel electrospray emitters.
    Su S; Gibson GT; Mugo SM; Marecak DM; Oleschuk RD
    Anal Chem; 2009 Sep; 81(17):7281-7. PubMed ID: 19715359
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Capillary liquid chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.
    Ostman P; Jäntti S; Grigoras K; Saarela V; Ketola RA; Franssila S; Kotiaho T; Kostiainen R
    Lab Chip; 2006 Jul; 6(7):948-53. PubMed ID: 16804601
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Modeling electroosmotic and pressure-driven flows in porous microfluidic devices: zeta potential and porosity changes near the channel walls.
    Scales N; Tait RN
    J Chem Phys; 2006 Sep; 125(9):094714. PubMed ID: 16965112
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of an on-target sample preparation system for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in conjunction with normal-flow peptide high-performance liquid chromatography for peptide mass fingerprint analyses.
    McComb ME; Perlman DH; Huang H; Costello CE
    Rapid Commun Mass Spectrom; 2007; 21(1):44-58. PubMed ID: 17133622
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Electrokinetic-driven microfluidic system in poly(dimethylsiloxane) for mass spectrometry detection integrating sample injection, capillary electrophoresis, and electrospray emitter on-chip.
    Thorslund S; Lindberg P; Andrén PE; Nikolajeff F; Bergquist J
    Electrophoresis; 2005 Dec; 26(24):4674-83. PubMed ID: 16273585
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Nanospray mass spectrometry with indirect conductive graphite coating.
    Viberg P; Nilsson S; Skog K
    Anal Chem; 2004 Jul; 76(14):4241-4. PubMed ID: 15253670
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Mapping of potential gradients within the electrospray emitter.
    Li Y; Pozniak BP; Cole RB
    Anal Chem; 2003 Dec; 75(24):6987-94. PubMed ID: 14670062
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Glass microfabricated nebulizer chip for mass spectrometry.
    Saarela V; Haapala M; Kostiainen R; Kotiaho T; Franssila S
    Lab Chip; 2007 May; 7(5):644-6. PubMed ID: 17476387
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.