180 related articles for article (PubMed ID: 16219244)
21. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.
Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D
J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760
[TBL] [Abstract][Full Text] [Related]
22. The Effect of Contamination of Implant Screws on Reverse Torque.
Lee HW; Alkumru H; Ganss B; Lai JY; Ramp LC; Liu PR
Int J Oral Maxillofac Implants; 2015; 30(5):1054-60. PubMed ID: 26394341
[TBL] [Abstract][Full Text] [Related]
23. Removal torque and force to failure of non-axially tightened implant abutment screws.
Goldberg J; Lee T; Phark JH; Chee W
J Prosthet Dent; 2019 Feb; 121(2):322-326. PubMed ID: 30139673
[TBL] [Abstract][Full Text] [Related]
24.
Selvamani N; Shanmugasundaram RA; Selvaraj A; Ranganathan G; Abraham S; Kirubakaran A
J Contemp Dent Pract; 2022 Aug; 23(8):801-806. PubMed ID: 37283014
[TBL] [Abstract][Full Text] [Related]
25. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
[TBL] [Abstract][Full Text] [Related]
26. The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws.
Tzenakis GK; Nagy WW; Fournelle RA; Dhuru VB
J Prosthet Dent; 2002 Aug; 88(2):183-91. PubMed ID: 12397246
[TBL] [Abstract][Full Text] [Related]
27. Early laser-welded titanium frameworks supported by implants in the edentulous mandible: a 15-year comparative follow-up study.
Ortorp A; Jemt T
Clin Implant Dent Relat Res; 2009 Dec; 11(4):311-22. PubMed ID: 18783415
[TBL] [Abstract][Full Text] [Related]
28. Deformation of implant retaining screws-Study with stereoscopic microscopy and microCT.
Batista R; Moreira A; Oliveira SJ; Mesquita P; Sampaio-Fernandes J; Figueiral MH
J Esthet Restor Dent; 2022 Dec; 34(8):1147-1155. PubMed ID: 36052667
[TBL] [Abstract][Full Text] [Related]
29. Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.
Ortorp A; Jemt T; Bäck T; Jälevik T
Int J Prosthodont; 2003; 16(2):194-200. PubMed ID: 12737254
[TBL] [Abstract][Full Text] [Related]
30. Bone response to implant-supported frameworks with differing degrees of misfit preload: in vivo study in rabbits.
Jemt T; Lekholm U; Johansson CB
Clin Implant Dent Relat Res; 2000; 2(3):129-37. PubMed ID: 11359257
[TBL] [Abstract][Full Text] [Related]
31. Implant-abutment screw joint preload of 7 hex-top abutment systems.
Tan KB; Nicholls JI
Int J Oral Maxillofac Implants; 2001; 16(3):367-77. PubMed ID: 11432656
[TBL] [Abstract][Full Text] [Related]
32. Loss of preload in screwed implant joints as a function of time and tightening/untightening sequences.
Bernardes SR; da Gloria Chiarello de Mattos M; Hobkirk J; Ribeiro RF
Int J Oral Maxillofac Implants; 2014; 29(1):89-96. PubMed ID: 24451858
[TBL] [Abstract][Full Text] [Related]
33. Effect of Framework's Manufacturing Technique on Screw's Preload of Implant Supported Prosthesis.
Alshehri H; Alotaibi H; Alshareef N; Alsenani N; Aljuma'ah L; Alshhrani W; Alsahhaf A
Niger J Clin Pract; 2022 Feb; 25(2):185-191. PubMed ID: 35170445
[TBL] [Abstract][Full Text] [Related]
34. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing.
Al Jabbari YS; Fournelle R; Ziebert G; Toth J; Iacopino AM
J Prosthodont; 2008 Apr; 17(3):192-200. PubMed ID: 18205737
[TBL] [Abstract][Full Text] [Related]
35. Clinical experiences of CNC-milled titanium frameworks supported by implants in the edentulous jaw: 1-year prospective study.
Ortorp A; Jemt T
Clin Implant Dent Relat Res; 2000; 2(1):2-9. PubMed ID: 11359272
[TBL] [Abstract][Full Text] [Related]
36. Effect of feldspathic porcelain layering on the marginal fit of zirconia and titanium complete-arch fixed implant-supported frameworks.
Yilmaz B; Alshahrani FA; Kale E; Johnston WM
J Prosthet Dent; 2018 Jul; 120(1):71-78. PubMed ID: 29426786
[TBL] [Abstract][Full Text] [Related]
37. CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10-year comparative clinical study.
Örtorp A; Jemt T
Clin Implant Dent Relat Res; 2012 Mar; 14(1):88-99. PubMed ID: 19686283
[TBL] [Abstract][Full Text] [Related]
38. Comparison of Customized Abutments Made from Titanium and a Machinable Precious Alloy.
Lee JH; Park JM; Park EJ; Koak JY; Kim SK; Heo SJ
Int J Oral Maxillofac Implants; 2016; 31(1):92-100. PubMed ID: 26800166
[TBL] [Abstract][Full Text] [Related]
39. Probabilistic analysis of preload in the abutment screw of a dental implant complex.
Guda T; Ross TA; Lang LA; Millwater HR
J Prosthet Dent; 2008 Sep; 100(3):183-93. PubMed ID: 18762030
[TBL] [Abstract][Full Text] [Related]
40. A clinical study of the efficacy of gold-tite square abutment screws in cement-retained implant restorations.
Drago CJ
Int J Oral Maxillofac Implants; 2003; 18(2):273-8. PubMed ID: 12705307
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]