156 related articles for article (PubMed ID: 16227834)
1. Intraocular pressure measurement over amniotic membrane patch in human subjects.
Hashizume A; Usui T; Yokoo S; Mimura T; Araie M; Yamagami S; Amano S
Cornea; 2005 Nov; 24(8):925-7. PubMed ID: 16227834
[TBL] [Abstract][Full Text] [Related]
2. Accuracy of intraocular pressure by Tono-Pen XL over amniotic membrane patching in rabbits.
Kobayashi A; Yoshita T; Shirao Y
Am J Ophthalmol; 2003 Apr; 135(4):536-7. PubMed ID: 12654373
[TBL] [Abstract][Full Text] [Related]
3. Reliability of intraocular pressure by Tono-Pen XL over amniotic membrane patch in human.
Yoshita T; Kobayashi A; Takahashi M; Sugiyama K
J Glaucoma; 2004 Oct; 13(5):413-6. PubMed ID: 15354081
[TBL] [Abstract][Full Text] [Related]
4. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model.
Neuburger M; Maier P; Böhringer D; Reinhard T; F Jordan J
J Glaucoma; 2013 Sep; 22(7):584-90. PubMed ID: 22366704
[TBL] [Abstract][Full Text] [Related]
5. Clinical evaluation of the accuracy of intraocular pressure measurement by Tono-Pen XL in eyes with amniotic membrane patching.
Onguchi T; Takano Y; Dogru M; Tsubota K; Shimazaki J
Am J Ophthalmol; 2005 Mar; 139(3):570-1. PubMed ID: 15767085
[TBL] [Abstract][Full Text] [Related]
6. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes].
Deuter CM; Schlote T; Hahn GA; Bende T; Derse M
Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes.
García-Resúa C; González-Meijome JM; Gilino J; Yebra-Pimentel E
Optom Vis Sci; 2006 Feb; 83(2):102-7. PubMed ID: 16501412
[TBL] [Abstract][Full Text] [Related]
8. Comparison of two handheld applanation tonometers and the association of central corneal thickness, age, and intraocular pressure in normal and diseased canine eyes.
Kato K
Vet Ophthalmol; 2014 Nov; 17(6):417-25. PubMed ID: 24517734
[TBL] [Abstract][Full Text] [Related]
9. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D
Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165
[TBL] [Abstract][Full Text] [Related]
10. Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer.
Midelfart A; Wigers A
Br J Ophthalmol; 1994 Dec; 78(12):895-8. PubMed ID: 7819170
[TBL] [Abstract][Full Text] [Related]
11. Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions.
Lee TE; Yoo C; Hwang JY; Lin S; Kim YY
Curr Eye Res; 2015 Sep; 40(9):923-9. PubMed ID: 25271991
[TBL] [Abstract][Full Text] [Related]
12. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology.
von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A
Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625
[TBL] [Abstract][Full Text] [Related]
13. Comparison of intraocular pressure measurements between the Tono-Pen XL® and Perkins® applanation tonometers in dogs and cats.
Andrade SF; Palozzi RJ; Giuffrida R; de Campos RJ; Santos Gde C; Fukui RM
Vet Ophthalmol; 2012 Mar; 15 Suppl 1():14-20. PubMed ID: 22050624
[TBL] [Abstract][Full Text] [Related]
14. Effect of central corneal thickness and radius of the corneal curvature on intraocular pressure measured with the Tono-Pen and noncontact tonometer in healthy schoolchildren.
Yildirim N; Sahin A; Basmak H; Bal C
J Pediatr Ophthalmol Strabismus; 2007; 44(4):216-22. PubMed ID: 17694826
[TBL] [Abstract][Full Text] [Related]
15. Comparison of Tono-Pen and Goldmann applanation tonometers for measurement of intraocular pressure in healthy children.
Bradfield YS; Kaminski BM; Repka MX; Melia M; ; Davitt BV; Johnson DA; Kraker RT; Manny RE; Matta NS; Schloff S; Weise KK
J AAPOS; 2012 Jun; 16(3):242-8. PubMed ID: 22459105
[TBL] [Abstract][Full Text] [Related]
16. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.
Bhan A; Browning AC; Shah S; Hamilton R; Dave D; Dua HS
Invest Ophthalmol Vis Sci; 2002 May; 43(5):1389-92. PubMed ID: 11980851
[TBL] [Abstract][Full Text] [Related]
17. A comparison of Icare PRO and Tono-Pen XL tonometers in anesthetized children.
McKee EC; Ely AL; Duncan JE; Dosunmu EO; Freedman SF
J AAPOS; 2015 Aug; 19(4):332-7. PubMed ID: 26235790
[TBL] [Abstract][Full Text] [Related]
18. Rebound tonometry over an air-filled anterior chamber in the supine child after intraocular surgery.
Davis R; Jiramongkolchai K; Silverstein E; Freedman SF
J AAPOS; 2016 Apr; 20(2):159-64. PubMed ID: 27079599
[TBL] [Abstract][Full Text] [Related]
19. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.
Browning AC; Bhan A; Rotchford AP; Shah S; Dua HS
Br J Ophthalmol; 2004 Nov; 88(11):1395-9. PubMed ID: 15489480
[TBL] [Abstract][Full Text] [Related]
20. Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry.
Badakere SV; Choudhari NS; Rao HL; Chary CR; Garudadri CS; Senthil S
Optom Vis Sci; 2018 Feb; 95(2):129-135. PubMed ID: 29370020
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]