These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 16232092)

  • 1. Mean and variance quality control for multiple correlated levels of replicated control samples.
    Livesey JH
    Clin Chem Lab Med; 2005; 43(11):1240-52. PubMed ID: 16232092
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Choosing quality-control systems to detect maximum clinically allowable analytical errors.
    Linnet K
    Clin Chem; 1989 Feb; 35(2):284-8. PubMed ID: 2914374
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mean and variance rules are more powerful or selective than quality control rules based on individual values.
    Linnet K
    Eur J Clin Chem Clin Biochem; 1991 Jul; 29(7):417-24. PubMed ID: 1932361
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The exponentially weighted moving average (EWMA) rule compared with traditionally used quality control rules.
    Linnet K
    Clin Chem Lab Med; 2006; 44(4):396-9. PubMed ID: 16599831
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new quality control model using performance goals based on biological variation in External Quality Assurance Schemes.
    Mina A
    Clin Chem Lab Med; 2006; 44(1):86-91. PubMed ID: 16375592
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multirule quality control procedures.
    Carey RN
    Ann Ist Super Sanita; 1991; 27(3):419-25. PubMed ID: 1809061
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance characteristics of rules for internal quality control: probabilities for false rejection and error detection.
    Westgard JO; Groth T; Aronsson T; Falk H; de Verdier CH
    Clin Chem; 1977 Oct; 23(10):1857-67. PubMed ID: 902411
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Error models and quality control performance.
    Chiecchio A; Malvano R
    Eur J Clin Chem Clin Biochem; 1996 May; 34(5):423-30. PubMed ID: 8790978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Internal quality control of prothrombin time in primary care: comparing the use of patient split samples with lyophilised control materials.
    Stavelin A; Petersen PH; Sølvik U; Sandberg S
    Thromb Haemost; 2009 Sep; 102(3):593-600. PubMed ID: 19718482
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The quality assurance system in clinical chemistry.
    Albertini A; Signorini C
    Ann Ist Super Sanita; 1995; 31(1):3-8. PubMed ID: 8546372
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Proposed guidelines for the internal quality control of analytical results in the medical laboratory.
    Petersen PH; Ricós C; Stöckl D; Libeer JC; Baadenhuijsen H; Fraser C; Thienpont L
    Eur J Clin Chem Clin Biochem; 1996 Dec; 34(12):983-99. PubMed ID: 8986407
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Components of quality control.
    Hurley AA
    Curr Protoc Cytom; 2001 May; Chapter 3():Unit 3.2. PubMed ID: 18770705
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Practical aspects of internal quality assurance.
    Uldall A
    Ann Ist Super Sanita; 1991; 27(3):411-7. PubMed ID: 1809060
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Probability and the Westgard Rules.
    Carroll TA; Pinnick HA; Carroll WE
    Ann Clin Lab Sci; 2003; 33(1):113-4. PubMed ID: 12661907
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A model for quality achievement--the NORDKEM protein project.
    Hyltoft Petersen P; Blaabjerg O; Irjala K; Icén A; Bjøro K
    Scand J Clin Lab Invest Suppl; 1993; 212():10-2. PubMed ID: 8465144
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of quality-control rules used in clinical chemistry laboratories.
    Bishop J; Nix AB
    Clin Chem; 1993 Aug; 39(8):1638-49. PubMed ID: 8353950
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Verification of out-of-control situations detected by "average of normal" approach.
    Liu J; Tan CH; Loh TP; Badrick T
    Clin Biochem; 2016 Nov; 49(16-17):1248-1253. PubMed ID: 27452179
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The impact of quality control materials on the performance of an internal quality control system: 1. General considerations.
    Hyltoft Petersen P; Hørder M; Blaabjerg O; Jørgensen PJ
    Scand J Clin Lab Invest Suppl; 1984; 172():65-9. PubMed ID: 6599531
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design and evaluation of statistical control procedures: applications of a computer "quality control simulator" program.
    Westgard JO; Groth T
    Clin Chem; 1981 Sep; 27(9):1536-45. PubMed ID: 7261331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of quality control materials on the performance of an internal quality control system: 2. Experiences from S-calcium analysis.
    Jørgensen PJ; Hørder M; Blaabjerg O; Hyltoft Petersen P; Haas V; Olsson V
    Scand J Clin Lab Invest Suppl; 1984; 172():71-7. PubMed ID: 6599532
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.