BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

405 related articles for article (PubMed ID: 16234218)

  • 1. Respiratory protection provided by N95 filtering facepiece respirators against airborne dust and microorganisms in agricultural farms.
    Lee SA; Adhikari A; Grinshpun SA; McKay R; Shukla R; Zeigler HL; Reponen T
    J Occup Environ Hyg; 2005 Nov; 2(11):577-85. PubMed ID: 16234218
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of performance of three different types of respiratory protection devices.
    Lawrence RB; Duling MG; Calvert CA; Coffey CC
    J Occup Environ Hyg; 2006 Sep; 3(9):465-74. PubMed ID: 16857645
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles.
    Balazy A; Toivola M; Reponen T; Podgórski A; Zimmer A; Grinshpun SA
    Ann Occup Hyg; 2006 Apr; 50(3):259-69. PubMed ID: 16344291
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Personal exposure to airborne dust and microorganisms in agricultural environments.
    Lee SA; Adhikari A; Grinshpun SA; McKay R; Shukla R; Reponen T
    J Occup Environ Hyg; 2006 Mar; 3(3):118-30. PubMed ID: 16484176
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Workplace protection factors for an N95 filtering facepiece respirator.
    Janssen LL; Nelson TJ; Cuta KT
    J Occup Environ Hyg; 2007 Sep; 4(9):698-707. PubMed ID: 17654225
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of particle size on respiratory protection provided by two types of N95 respirators used in agricultural settings.
    Cho KJ; Jones S; Jones G; McKay R; Grinshpun SA; Dwivedi A; Shukla R; Singh U; Reponen T
    J Occup Environ Hyg; 2010 Nov; 7(11):622-7. PubMed ID: 20835946
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of workplace protection factors for different biological contaminants.
    Cho KJ; Reponen T; McKay R; Dwivedi A; Adhikari A; Singh U; Shukla R; Jones S; Jones G; Grinshpun SA
    J Occup Environ Hyg; 2011 Jul; 8(7):417-25. PubMed ID: 21732855
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simulated workplace protection factors for half-facepiece respiratory protective devices.
    Duling MG; Lawrence RB; Slaven JE; Coffey CC
    J Occup Environ Hyg; 2007 Jun; 4(6):420-31. PubMed ID: 17474032
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laboratory and field evaluation of a new personal sampling system for assessing the protection provided by the N95 filtering facepiece respirators against particles.
    Lee SA; Grinshpun SA; Adhikari A; Li W; McKay R; Maynard A; Reponen T
    Ann Occup Hyg; 2005 Apr; 49(3):245-57. PubMed ID: 15668259
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nanoparticle penetration through filter media and leakage through face seal interface of N95 filtering facepiece respirators.
    Rengasamy S; Eimer BC
    Ann Occup Hyg; 2012 Jul; 56(5):568-80. PubMed ID: 22294504
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Using half-facepiece respirators for H1N1.
    Larson S
    Occup Health Saf; 2009 Nov; 78(11):22, 24. PubMed ID: 19927872
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks?
    Bałazy A; Toivola M; Adhikari A; Sivasubramani SK; Reponen T; Grinshpun SA
    Am J Infect Control; 2006 Mar; 34(2):51-7. PubMed ID: 16490606
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles.
    Adhikari A; Mitra A; Rashidi A; Ekpo I; Schwartz J; Doehling J
    Int J Environ Res Public Health; 2018 Sep; 15(9):. PubMed ID: 30205526
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance of a full facepiece, air-purifying respirator against lead aerosols in a workplace environment.
    Janssen L; Bidwell J
    J Occup Environ Hyg; 2007 Feb; 4(2):123-8. PubMed ID: 17175515
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Total inward leakage measurement of particulates for N95 filtering facepiece respirators--a comparison study.
    Rengasamy S; Walbert GF; Newcomb WE; Faulkner K; Rengasamy MM; Brannen JJ; Szalajda JV
    Ann Occup Hyg; 2014 Mar; 58(2):206-16. PubMed ID: 24107745
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Statistical issues with respect to workplace protection factors for respirators.
    Crump KS
    J Occup Environ Hyg; 2007 Mar; 4(3):208-14. PubMed ID: 17237026
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Respirator Performance against Nanoparticles under Simulated Workplace Activities.
    Vo E; Zhuang Z; Horvatin M; Liu Y; He X; Rengasamy S
    Ann Occup Hyg; 2015 Oct; 59(8):1012-21. PubMed ID: 26180261
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Filtration performance of NIOSH-approved N95 and P100 filtering facepiece respirators against 4 to 30 nanometer-size nanoparticles.
    Rengasamy S; King WP; Eimer BC; Shaffer RE
    J Occup Environ Hyg; 2008 Sep; 5(9):556-64. PubMed ID: 18607812
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiratory protection from isocyanate exposure in the autobody repair and refinishing industry.
    Liu Y; Stowe MH; Bello D; Woskie SR; Sparer J; Gore R; Youngs F; Cullen MR; Redlich CA
    J Occup Environ Hyg; 2006 May; 3(5):234-49. PubMed ID: 16574607
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Field performance measurements of half-facepiece respirators: steel mill operations.
    Myers WR; Zhuang Z
    Am Ind Hyg Assoc J; 1998 Nov; 59(11):789-95. PubMed ID: 9830087
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.