These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 16235033)

  • 21. Experimental investigation of the steady flow downstream of the St. Jude bileaflet heart valve: a comparison between laser Doppler velocimetry and particle image velocimetry techniques.
    Browne P; Ramuzat A; Saxena R; Yoganathan AP
    Ann Biomed Eng; 2000 Jan; 28(1):39-47. PubMed ID: 10645786
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of the Different Mechanical Mitral Valve Sounds on the Patients' Quality of Life.
    Huang JS; Hong ZN; Sun KP; Cao H; Chen Q
    Thorac Cardiovasc Surg; 2020 Sep; 68(6):492-497. PubMed ID: 31491792
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Subjective noise perception and objective measurement of loudness following heart valve replacement with the St. Jude Medical and Duromedics Edwards bileaflet prostheses].
    Moritz A; Kobinia G; Steinseifer U; Wolters H; Reul H; Neuwirth-Riedl K; Messmer B; Rau G
    Z Kardiol; 1989 Dec; 78(12):784-9. PubMed ID: 2623921
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Vortex shedding in bileaflet heart valve prostheses.
    Gross JM; Shermer CD; Hwang NH
    ASAIO Trans; 1988; 34(3):845-50. PubMed ID: 3196609
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The closing behavior of mechanical aortic heart valve prostheses.
    Lu PC; Liu JS; Huang RH; Lo CW; Lai HC; Hwang NH
    ASAIO J; 2004; 50(4):294-300. PubMed ID: 15307536
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pressure and flow fields in the hinge region of bileaflet mechanical heart valves.
    Gao ZB; Hosein N; Dai FF; Hwang NH
    J Heart Valve Dis; 1999 Mar; 8(2):197-205. PubMed ID: 10224581
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hemodynamics of the mitral valve under edge-to-edge repair: an in vitro steady flow study.
    Shi L; He Z
    J Biomech Eng; 2009 May; 131(5):051010. PubMed ID: 19388780
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Tomographic PIV in a model of the left ventricle: 3D flow past biological and mechanical heart valves.
    Saaid H; Voorneveld J; Schinkel C; Westenberg J; Gijsen F; Segers P; Verdonck P; de Jong N; Bosch JG; Kenjeres S; Claessens T
    J Biomech; 2019 Jun; 90():40-49. PubMed ID: 31030891
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Causes and formation of cavitation in mechanical heart valves.
    Graf T; Reul H; Detlefs C; Wilmes R; Rau G
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S49-64. PubMed ID: 8061870
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Role of vortices in cavitation formation in the flow at the closure of a bileaflet mitral mechanical heart valve.
    Li CP; Chen SF; Lo CW; Lu PC
    J Artif Organs; 2012 Mar; 15(1):57-64. PubMed ID: 22015913
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.
    Lee H; Ikeuchi Y; Akagawa E; Tatsumi E; Taenaka Y; Yamamoto T
    J Artif Organs; 2009; 12(2):98-104. PubMed ID: 19536626
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Time-resolved DPIV analysis of vortex dynamics in a left ventricular model through bileaflet mechanical and porcine heart valve prostheses.
    Pierrakos O; Vlachos PP; Telionis DP
    J Biomech Eng; 2004 Dec; 126(6):714-26. PubMed ID: 15796330
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study.
    Jahandardoost M; Fradet G; Mohammadi H
    Proc Inst Mech Eng H; 2016 Mar; 230(3):175-90. PubMed ID: 26786673
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.
    Shi Y; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):245-55. PubMed ID: 12701798
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical evaluation of ATS prosthetic valve by doppler echocardiography: comparison with St. Jude Medical (SJM) valve.
    Hasegawa M
    Ann Thorac Cardiovasc Surg; 2000 Aug; 6(4):247-51. PubMed ID: 11042481
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A new method for quantitative evaluation of perceived sounds from mechanical heart valve prostheses.
    Johansen P; Riis C; Hasenkam JM; Paulsen PK; Nygaard H
    Proc Inst Mech Eng H; 2000; 214(1):121-8. PubMed ID: 10718056
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The closing velocity of mechanical heart valve leaflets.
    Guo GX; Chiang TH; Quijano RC; Hwang NH
    Med Eng Phys; 1994 Nov; 16(6):458-64. PubMed ID: 7858776
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Integrating particle image velocimetry and laser Doppler velocimetry measurements of the regurgitant flow field past mechanical heart valves.
    Kini V; Bachmann C; Fontaine A; Deutsch S; Tarbell JM
    Artif Organs; 2001 Feb; 25(2):136-45. PubMed ID: 11251479
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Are sounds from mechanical heart valves equal for different valve types?
    Pedersen TA; Johansen P; Hasenkam JM; Koerfer R; Koertke H; Nygaard H
    J Heart Valve Dis; 2008 Sep; 17(5):579-82. PubMed ID: 18980093
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ventricular pressure slope and bileaflet mechanical heart valve closure.
    Wu ZJ; Hwang NH
    ASAIO J; 1995; 41(3):M763-7. PubMed ID: 8573909
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.