These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

297 related articles for article (PubMed ID: 16235034)

  • 1. Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses.
    Akutsu T; Fukuda T
    J Artif Organs; 2005; 8(3):171-83. PubMed ID: 16235034
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.
    Akutsu T; Saito J
    J Artif Organs; 2006; 9(3):165-78. PubMed ID: 16998702
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of the flow field of mechanical bileaflet mitral prostheses on valve closing.
    Akutsu T; Imai R; Deguchi Y
    J Artif Organs; 2005; 8(3):161-70. PubMed ID: 16235033
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis.
    Akutsu T; Masuda T
    J Artif Organs; 2003; 6(2):112-23. PubMed ID: 14598112
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correlation between ventricular flow field and valve closing sound of mechanical mitral prostheses.
    Akutsu T; Imai R; Saito J; Suzuki T
    J Artif Organs; 2008; 11(2):67-74. PubMed ID: 18604611
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses.
    Akutsu T; Saito J; Imai R; Suzuki T; Cao XD
    J Artif Organs; 2008; 11(2):75-90. PubMed ID: 18604612
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow.
    Saxena R; Lemmon J; Ellis J; Yoganathan A
    J Thorac Cardiovasc Surg; 2003 Jul; 126(1):90-8. PubMed ID: 12878943
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental investigation of the steady flow downstream of the St. Jude bileaflet heart valve: a comparison between laser Doppler velocimetry and particle image velocimetry techniques.
    Browne P; Ramuzat A; Saxena R; Yoganathan AP
    Ann Biomed Eng; 2000 Jan; 28(1):39-47. PubMed ID: 10645786
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry.
    Manning KB; Kini V; Fontaine AA; Deutsch S; Tarbell JM
    Artif Organs; 2003 Sep; 27(9):840-6. PubMed ID: 12940907
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow.
    Subramanian A; Mu H; Kadambi JR; Wernet MP; Brendzel AM; Harasaki H
    J Heart Valve Dis; 2000 Sep; 9(5):721-31. PubMed ID: 11041190
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laser Doppler anemometry study of bidimensional flows downstream of three 19 mm bileaflet valves in the mitral position, under kinematic similarity.
    Grigioni M; Daniele C; D'Avenio G; Barbaro V
    Ann Biomed Eng; 2000 Feb; 28(2):194-203. PubMed ID: 10710191
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta.
    Akutsu T; Matsumoto A
    J Artif Organs; 2010 Dec; 13(4):207-17. PubMed ID: 20924771
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro fluid dynamic evaluation of the Carbomedics bileaflet heart valve prosthesis in the aortic and mitral positions.
    Sung HW; Cape EG; Yoganathan AP
    J Heart Valve Dis; 1994 Nov; 3(6):673-83. PubMed ID: 8000612
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses).
    Barbaro V; Grigioni M; Daniele C; D'Avenio G; Boccanera G
    Int J Artif Organs; 1997 Nov; 20(11):629-36. PubMed ID: 9464873
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation technique for bileaflet mechanical valves.
    Shipkowitz T; Ambrus J; Kurk J; Wickramasinghe K
    J Heart Valve Dis; 2002 Mar; 11(2):275-82. PubMed ID: 12000172
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Integrating particle image velocimetry and laser Doppler velocimetry measurements of the regurgitant flow field past mechanical heart valves.
    Kini V; Bachmann C; Fontaine A; Deutsch S; Tarbell JM
    Artif Organs; 2001 Feb; 25(2):136-45. PubMed ID: 11251479
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve.
    Barbaro V; Grigioni M; Daniele C; D'Avenio G
    Technol Health Care; 1998 Nov; 6(4):259-70. PubMed ID: 9924953
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An experimental study of steady flow patterns of a new trileaflet mechanical aortic valve.
    Liu JS; Lu PC; Lo CW; Lai HC; Hwang NH
    ASAIO J; 2005; 51(4):336-41. PubMed ID: 16156295
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Digital particle image velocimetry (DPIV) measurements of the velocity profiles through bileaflet mechanical valves: in vitro steady.
    Shandas R; Kwon J
    Biomed Sci Instrum; 1996; 32():161-7. PubMed ID: 8672664
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.