These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 1623600)

  • 1. Design and preliminary performance characteristics of a newly proposed reference cell for ionized calcium in serum.
    D'Orazio P; Bowers GN
    Clin Chem; 1992 Jul; 38(7):1332-9. PubMed ID: 1623600
    [TBL] [Abstract][Full Text] [Related]  

  • 2. IFCC recommended reference method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood.
    Burnett RW; Christiansen TF; Covington AK; Fogh-Andersen N; Külpmann WR; Lewenstam A; Maas AHJ ; Müller-Plathe O; Sachs C; Andersen OS; VanKessel AL; Zijlstra WG;
    Clin Chem Lab Med; 2000 Dec; 38(12):1301-14. PubMed ID: 11205698
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dependence of measured ionized calcium on protein concentration as measured by three ion-selective electrodes.
    McEnroe E; McKenna MJ; Diamond D; Covington AK; Freaney R
    Ann Clin Biochem; 1992 Jul; 29 ( Pt 4)():443-9. PubMed ID: 1642453
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A reliable potentiometric measurement of ionized calcium and pH on the ICA2 Radiometer in clinical practice.
    Gouget B; Gourmelin Y; Blanchet F; Truchaud A
    Scand J Clin Lab Invest; 1989 Jun; 49(4):345-9. PubMed ID: 2740827
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aqueous and serum-based materials compared for use as simulated calibrators for three ionized calcium analyzers.
    Toffaletti J; Bird C; Berg C; Abrams B
    Clin Chem; 1986 Aug; 32(8):1548-50. PubMed ID: 3731449
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analyzer-dependent differences in results for ionized calcium, ionized magnesium, sodium, and pH.
    Hristova EN; Cecco S; Niemela JE; Rehak NN; Elin RJ
    Clin Chem; 1995 Nov; 41(11):1649-53. PubMed ID: 7586557
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Serum ionized magnesium levels and serum ionized calcium/ionized magnesium ratios in women with menstrual migraine.
    Mauskop A; Altura BT; Altura BM
    Headache; 2002 Apr; 42(4):242-8. PubMed ID: 12010379
    [TBL] [Abstract][Full Text] [Related]  

  • 8. IFCC reference methods for measurement of pH, gases and electrolytes in blood: reference materials.
    Maas AH
    Eur J Clin Chem Clin Biochem; 1991 Apr; 29(4):253-61. PubMed ID: 1868131
    [TBL] [Abstract][Full Text] [Related]  

  • 9. IFCC reference methods and materials for measurement of pH, gases and electrolytes in blood.
    Maas AH
    Scand J Clin Lab Invest Suppl; 1993; 214():83-94. PubMed ID: 8332857
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calcium measurements in serum and plasma--total and ionized.
    Robertson WG; Marshall RW
    CRC Crit Rev Clin Lab Sci; 1979 Dec; 11(3):271-304. PubMed ID: 116800
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy evaluation and hematocrit effect of commercial ionized calcium analyzers using Japanese serum reference material.
    Kuwa K; Tani W; Hayashi K; Umemoto M
    Scand J Clin Lab Invest Suppl; 1996; 224():173-7. PubMed ID: 8865433
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ionized calcium in normal serum, ultrafiltrates, and whole blood determined by ion-exchange electrodes.
    Moore EW
    J Clin Invest; 1970 Feb; 49(2):318-34. PubMed ID: 4983663
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Deficiency in serum ionized magnesium but not total magnesium in patients with migraines. Possible role of ICa2+/IMg2+ ratio.
    Mauskop A; Altura BT; Cracco RQ; Altura BM
    Headache; 1993 Mar; 33(3):135-8. PubMed ID: 8486510
    [TBL] [Abstract][Full Text] [Related]  

  • 14. IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma.
    Ben Rayana MC; Burnett RW; Covington AK; D'Orazio P; Fogh-Andersen N; Jacobs E; Külpmann WR; Kuwa K; Larsson L; Lewenstam A; Maas AH; Mager G; Naskalski JW; Okorodudu AO; Ritter C; St John A; ;
    Clin Chem Lab Med; 2008; 46(1):21-6. PubMed ID: 17663628
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.
    Grima JM; Brand MJ
    Clin Chem; 1977 Nov; 23(11):2048-54. PubMed ID: 21042
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ca2+ measurement with ion selective electrodes. The French coordinated evaluation of seven analyzers, for a better clinical relevance and acceptance.
    Gouget B; Gourmelin Y; Blanchet F; Capolaghi B; Feuillu A; Lagente M; Lardet G; Manceaux JC; Pasquier C; Turret M
    Ann Biol Clin (Paris); 1988; 46(7):419-34. PubMed ID: 3056127
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of syringes for ionized calcium measurements.
    Sachs C; Rabouine P; Dautzenberg MD
    Scand J Clin Lab Invest Suppl; 1996; 224():193-201. PubMed ID: 8865436
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs.
    Bowers GN; Brassard C; Sena SF
    Clin Chem; 1986 Aug; 32(8):1437-47. PubMed ID: 3524900
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ionized calcium: its significance and clinical usefulness.
    Forman DT; Lorenzo L
    Ann Clin Lab Sci; 1991; 21(5):297-304. PubMed ID: 1952778
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Anomalies in pH 7.40 correction in ionised calcium analysers.
    Sachs C; Chaneac M; Rabouine P; Kindermans C; Dechaux M
    Ann Clin Biochem; 1989 Nov; 26 ( Pt 6)():542-6. PubMed ID: 2619235
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.