  • 21. Acoustic vector tomography and its application to magnetoacoustic tomography with magnetic induction (MAT-MI).
    Li X; Xia R; He B
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5834-6. PubMed ID: 19164044
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A reconstruction algorithm of magnetoacoustic tomography with magnetic induction for an acoustically inhomogeneous tissue.
    Zhou L; Zhu S; He B
    IEEE Trans Biomed Eng; 2014 Jun; 61(6):1739-46. PubMed ID: 24845284
    [TBL] [Abstract][Full Text] [Related]  

  • 23. New reconstruction method of magnetoacoustic tomography with magnetic induction.
    Zhang Y; Liu G; He W; Xia H; Li Y; Li S; Xu J
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3061-4. PubMed ID: 21095734
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Difference frequency magneto-acousto-electrical tomography (DF-MAET): application of ultrasound-induced radiation force to imaging electrical current density.
    Renzhiglova E; Ivantsiv V; Xu Y
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Nov; 57(11):2391-402. PubMed ID: 21041128
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Induced current magnetic resonance-electrical impedance tomography.
    Ozparlak L; Ider YZ
    Physiol Meas; 2005 Apr; 26(2):S289-305. PubMed ID: 15798242
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Image Reconstruction in Magnetoacoustic Tomography With Magnetic Induction With Variable Sound Speeds.
    Zhang W; Ma R; Zhang S; Yin T; Liu Z
    IEEE Trans Biomed Eng; 2016 Dec; 63(12):2585-2594. PubMed ID: 27576240
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Acoustic Source Analysis of Magnetoacoustic Tomography With Magnetic Induction for Conductivity Gradual-Varying Tissues.
    Wang J; Zhou Y; Sun X; Ma Q; Zhang D
    IEEE Trans Biomed Eng; 2016 Apr; 63(4):758-64. PubMed ID: 26292332
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Imaging biological tissues with electrical conductivity contrast below 1 S m by means of magnetoacoustic tomography with magnetic induction.
    Hu G; Li X; He B
    Appl Phys Lett; 2010 Sep; 97(10):. PubMed ID: 20938494
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Magnetoacoustic tomography with magnetic induction (MAT-MI) for breast tumor imaging: numerical modeling and simulation.
    Zhou L; Li X; Zhu S; He B
    Phys Med Biol; 2011 Apr; 56(7):1967-83. PubMed ID: 21364262
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison study of three different image reconstruction algorithms for MAT-MI.
    Xia R; Li X; He B
    IEEE Trans Biomed Eng; 2010 Mar; 57(3):708-13. PubMed ID: 19846363
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Magneto-Acousto-Electrical Tomography With Magnetic Induction for Conductivity Reconstruction.
    Guo L; Liu G; Xia H
    IEEE Trans Biomed Eng; 2015 Sep; 62(9):2114-24. PubMed ID: 25532166
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In Vivo Electrical Conductivity Contrast Imaging in a Mouse Model of Cancer Using High-Frequency Magnetoacoustic Tomography With Magnetic Induction (hfMAT-MI).
    Kai Yu ; Qi Shao ; Ashkenazi S; Bischof JC; Bin He
    IEEE Trans Med Imaging; 2016 Oct; 35(10):2301-2311. PubMed ID: 27834641
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Local harmonic B(z) algorithm with domain decomposition in MREIT: computer simulation study.
    Seo JK; Kim SW; Kim S; Liu JJ; Woo EJ; Jeon K; Lee CO
    IEEE Trans Med Imaging; 2008 Dec; 27(12):1754-61. PubMed ID: 19033091
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Magnetic resonance driven electrical impedance tomography: a simulation study.
    Negishi M; Tong T; Constable RT
    IEEE Trans Med Imaging; 2011 Mar; 30(3):828-37. PubMed ID: 21147595
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Image reconstruction in magnetic resonance conductivity tensor imaging (MRCTI).
    Değirmenci E; Eyüboğlu BM
    IEEE Trans Med Imaging; 2012 Mar; 31(3):525-32. PubMed ID: 21990330
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT).
    Oh SH; Han JY; Lee SY; Cho MH; Lee BI; Woo EJ
    Magn Reson Med; 2003 Oct; 50(4):875-8. PubMed ID: 14523975
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Magneto-acousto-electrical tomography: a potential method for imaging current density and electrical impedance.
    Haider S; Hrbek A; Xu Y
    Physiol Meas; 2008 Jun; 29(6):S41-50. PubMed ID: 18544798
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Anisotropic conductivity imaging with MREIT using equipotential projection algorithm.
    Değirmenci E; Eyüboğlu BM
    Phys Med Biol; 2007 Dec; 52(24):7229-42. PubMed ID: 18065836
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Noninvasive imaging of bioimpedance distribution by means of current reconstruction magnetic resonance electrical impedance tomography.
    Gao N; He B
    IEEE Trans Biomed Eng; 2008 May; 55(5):1530-8. PubMed ID: 18440899
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Electromagnetic forward and inverse problems of non-rotating magnetoacoustic tomography with magnetic induction.
    Zhang Y; Liu G; Tao C; Wang H; He W
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2292-5. PubMed ID: 19965169
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]