2. [Applanation tonometry in "normal" patients and patients after LASIK]. Kohlhaas M; Spörl E; Böhm AG; Pollack K; Sandner D; Pillunat LE Klin Monbl Augenheilkd; 2005 Oct; 222(10):823-6. PubMed ID: 16240277 [TBL] [Abstract][Full Text] [Related]
3. Clinical evaluation of applanation resonance tonometry: a comparison with Goldmann applanation tonometry. Hallberg P; Eklund A; Bäcklund T; Lindén C J Glaucoma; 2007 Jan; 16(1):88-93. PubMed ID: 17224756 [TBL] [Abstract][Full Text] [Related]
4. Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model. Hallberg P; Santala K; Lindén C; Lindahl OA; Eklund A J Med Eng Technol; 2006; 30(6):345-52. PubMed ID: 17060162 [TBL] [Abstract][Full Text] [Related]
5. Comparison of the rebound tonometer (ICare) to the applanation tonometer (Tonopen XL) in normotensive dogs. Leiva M; Naranjo C; Peña MT Vet Ophthalmol; 2006; 9(1):17-21. PubMed ID: 16409240 [TBL] [Abstract][Full Text] [Related]
6. [Statistical methods for comparison of two measuring procedures and for calibration: analysis of concordance, correlation and regression in the case of measuring intraocular pressure]. Koch R; Spörl E Klin Monbl Augenheilkd; 2007 Jan; 224(1):52-7. PubMed ID: 17260320 [TBL] [Abstract][Full Text] [Related]
7. [Standardization and calibration of tonometers. The importance of testing stations for the precision of clinical tonometry]. Draeger J Klin Monbl Augenheilkd; 2002 Oct; 219(10):701-2. PubMed ID: 12447713 [No Abstract] [Full Text] [Related]
9. [The role of pachymetry in routine glaucoma diagnosis]. von Eicken J; Kohlhaas M; Stodtmeister R; Höh H Klin Monbl Augenheilkd; 2006 Feb; 223(2):117-30. PubMed ID: 16485223 [TBL] [Abstract][Full Text] [Related]
10. Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes. Mollan SP; Wolffsohn JS; Nessim M; Laiquzzaman M; Sivakumar S; Hartley S; Shah S Br J Ophthalmol; 2008 Dec; 92(12):1661-5. PubMed ID: 18757471 [TBL] [Abstract][Full Text] [Related]
11. [On the clinical significance of calibration of applanation tonometers]. Draeger J Ber Zusammenkunft Dtsch Ophthalmol Ges; 1968; 68():345-50. PubMed ID: 5756793 [No Abstract] [Full Text] [Related]
15. The accuracy of continued clinical use of goldmann applanation tonometers with known calibration errors. Sandhu SS; Chattopadhyay S; Amariotakis GA; Skarmoutsos F; Birch MK; Ray-Chaudhuri N Ophthalmology; 2009 Jan; 116(1):9-13. PubMed ID: 18801579 [TBL] [Abstract][Full Text] [Related]
16. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes]. Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250 [TBL] [Abstract][Full Text] [Related]
17. Measurement of Goldmann applanation tonometer calibration error. Choudhari NS; George R; Baskaran M; Vijaya L; Dudeja N Ophthalmology; 2009 Jan; 116(1):3-8. PubMed ID: 18708256 [TBL] [Abstract][Full Text] [Related]
19. Comparison of the use of new handheld tonometers and established applanation tonometers in dogs. Görig C; Coenen RT; Stades FC; Djajadiningrat-Laanen SC; Boevé MH Am J Vet Res; 2006 Jan; 67(1):134-44. PubMed ID: 16426223 [TBL] [Abstract][Full Text] [Related]
20. Applanation tonometry and its calibration. Stuckey GC; Flanagan J Trans Aust Coll Ophthalmol; 1971; 3():138-41. PubMed ID: 5161778 [No Abstract] [Full Text] [Related] [Next] [New Search]